Ebyte E32-DTU-V8 Скачать руководство пользователя страница 9

Chengdu Ebyte Electronic Technology Co., Ltd.

E32-DTU(433L33)-V8 User Manual

Copyright ©2012–2022

Chengdu Ebyte Electronic Technology Co., Ltd.

9

3

485_B

RS-485 interface, interface B

The RS-485 interface B is connected to the

device interface B

4

485_A

RS-485 interface, interface A

The RS-485 interface A is connected to the

device interface A

Note: The transceiver will be in poor communication when connected to multiple devices , it is recommended to be
connected to a single device, please try to use parallel 120Ω resistor between 485_A terminal and 485_B.

5

Technical specification

5.1 Model specification

Model No.

Frequency

TX power

Distance

Features

Recommended application

Hz

W

km

E32-DTU(433L33

)-V8

433M

2

12

LoRa

anti-interference

Suitable for small data and long-distance
application environment

Note: Test condition: in clear and open air without shelters, 12V /2A power supply, 5dBi gain sucker antenna over 2
meters height from the ground, with the factory default parameters.

5.2 General specification parameter

No.

Item

Value

Note

1

Size

82*62*25mm

See more in

3.2. Dimensions

2

Weight

150g

Difference is within 5g

3

Temperature

-40℃

+85℃

Meet industrial request

4

Antenna

impedance

50Ω

Standard 50 Ω characteristic impedance

5

Supply voltage

8

28V DC

It is recommended to use 12V or 24V

6

Communicatio

n interface

RS232/RS485

Standard DB9 hole / 3.81 terminal block

7

Baud rate

Factory default 9600

From 1200~115200

8

Address code

Factory default 0

65536 configurable address

5.3 Frequency and channel numbers

Model No.

Default Frequency

Frequency Range

Channel

Interval

Channel numbers

Hz

Hz

Hz

Содержание E32-DTU-V8

Страница 1: ...Chengdu Ebyte Electronic Technology Co Ltd E32 DTU 433L33 V8 User Manual Copyright 2012 2022 Chengdu Ebyte Electronic Technology Co Ltd 1 E32 DTU 433L33 V8...

Страница 2: ...inition 8 4 1 Power interface 8 4 2 RS232 8 4 3 RS485 8 5 Technical specification 9 5 1 Model specification 9 5 2 General specification parameter 9 5 3 Frequency and channel numbers 9 5 4 Transmitting...

Страница 3: ...sions such as many and scattered points and complex geographical environment It can be connected with PLC RTU rain gauge liquid level gauge and other data terminals 1 2 Features Adopts military grade...

Страница 4: ...nd ensure that the DIP switch is in the correct state The user can choose the screwing method or the power adapter to supply power according to their needs 2 Use USB to RS 232 USB to RS 485 or other m...

Страница 5: ...eeds to modify the parameters please set dip switch in the configuration mode and connect it to the computer Open the E90 DTU configuration software to modify the relevant parameters After the configu...

Страница 6: ...supply Standard RS485 interface and screwing power interface 3 PWR LED Power Indicator Red lights up when the power is on 4 TXD LED TX indicator Yellow flashes when sending data 5 RXD LED RX indicato...

Страница 7: ...Chengdu Ebyte Electronic Technology Co Ltd E32 DTU 433L33 V8 User Manual Copyright 2012 2022 Chengdu Ebyte Electronic Technology Co Ltd 7 mm...

Страница 8: ...are optional 8 28V DC power supply it is recommended to use 12V or 24V DC power supply for E32 DTU 4 2 RS232 The E32 DTU can be connected to the device via RS 232 using the standard DB 9 interface 4 3...

Страница 9: ...V8 433M 2 12 LoRa anti interference Suitable for small data and long distance application environment Note Test condition in clear and open air without shelters 12V 2A power supply 5dBi gain sucker a...

Страница 10: ...ata rate the faster the transmission rate the transmission distance is also closer when the rate meets the requirements the lower air data rate the better quality 5 6 Current Model TX current mA Stand...

Страница 11: ...transmission is on configuration over air via special command is available Mode 1 WOR Mode ON OFF Can be defined as WOR transmitter and WOR receiver WOR is available Mode 2 Configuration Mode OFF ON U...

Страница 12: ...Programming the modem 7 1 Connection diagram Mode M1 M0 Note Sleep mode OFF OFF Programming via the configuration software is available only in this mode Note 1 When programming please check whether...

Страница 13: ...by 2 5MHz Transmit power The output power is the power radiated to the outside In order to ensure the working efficiency it is recommended to use the maximum power If the transmit power is reduced the...

Страница 14: ...oRa long distance anti inference E95 DTU 433L30 485 V8 RS485 410 441M 30 8 LoRa long distance anti inference E96 DTU 433L20 485 V8 RS485 410 441M 20 3 LoRa long distance anti inference E96 DTU 433L30...

Страница 15: ...ion state otherwise the transmitter may be burned out 5 The ground wire of the data transceiver should be well connected with that of the external equipment such as PC PLC etc and of the power supply...

Страница 16: ...d not exceed 100mV 10 Wireless communication products need to be connected with an impedance matching antenna to work properly even for short term testing About us Technical support support cdebyte co...

Отзывы: