Chengdu Ebyte Electronic Technology Co,;Ltd
E32-915T30S user manual
Copyright ©2012–2019
,
Chengdu Ebyte Electronic Technology Co.,Ltd.
4
Building automation solutions
;
Wireless industrial-grade remote control
;
Health care products
;
Advanced Meter Reading Architecture(AMI)
;
Automotive industry applications.
2. Specification and parameter
2.1 Limit parameter
Main parameter
Performance
Remark
Min.
Max.
Power supply
(
V
)
0
5.2
Voltage over 5.2V will cause permanent
damage to module
Blocking power
(
dBm
)
-
-10
Chances of burn is slim when modules
are used in short distance
Operating temperature
(℃)
-40
85
2.2 Operating parameter
Main parameter
Performance
Remark
Min
Typ.
Max.
Operating voltage
(
V
)
3.3
5.0
5.2
≥5.0 V ensures output power
Communication level
(
V
)
3.3
For 5V TTL, it may be at risk of
burning down
Operating temperature
(℃)
-40
-
85
Industrial design
Operating frequency
(
MHz
)
900
915
931
Support ISM band
Power
consumption
Transmitting current [mA]
600
Instant power consumption
Receiving current [mA]
21
Turn-off current [μA]
5
Software is shut down
Max Tx power
(
dBm
)
29.5
-
30.5
Receiving sensitivity
(
dBm
)
-145
-147
-148
Air data rate is 0.3kbps
Air data rate
(
bps
)
0.3k
2.4k
19.2k
Controlled via user’s programming
Main parameter
Description
Remark
Distance for reference
8000m
Test condition
:
clear and open area, antenna gain: 5dBi
,
antenna height: 2.5m
,
air data rate: 2.4kbps
TX length
58 Byte
Maximum capacity of single package
Buffer
512 Byte