background image

Chengdu Ebyte Electronic Technology Co.,Ltd.

E32-900M30SA User Manual

Copyright ©2012–2021

Chengdu Ebyte Electronic Technology Co.,Ltd.

7

14

DIO3

Input/Output

General IO port (see SX1276 manual for details)

15

DIO4

Input/Output

General IO port (see SX1276 manual for details)

16

DIO5

Input/Output

General IO port (see SX1276 manual for details)

17

GND

-

Ground

18

GND

-

Ground

19

DIO1

Input/Output

General IO port (see SX1276 manual for details)

20

DIO0

Input/Output

General IO port (see SX1276 manual for details)

21

NRST

Input

Chip reset trigger input pin

22

MISO

Output

SPI data output pin

23

MOSI

Input

SPI data output pin

24

SCLK

Input

SPI data output pin

25

NSS

Input

the module chip selects the pin used to start an SPI communication

26

GND

-

Ground

27

ANT

-

Antenna interface, Sample hole (50

Ω

characteristic impedance)

28

GND

-

Ground

4 Basic operation

4.1 Hardware design

It is recommended to use a DC stabilized power supply. The power supply ripple factor is as small as possible and
the module needs to be reliably grounded;

Please pay attention to the correct connection of the positive and negative poles of the power supply,

reverse connection may cause permanent damage to the module;

Please check the power supply to ensure that between the recommended supply voltage, if exceeding the maximum,
the module will be permanently damaged;

Please check the stability of the power supply. Voltage can not fluctuate greatly and frequently;

When designing the power supply circuit for the module, it is often recommended to reserve more than 30% of the
margin, so the whole machine is beneficial for long-term stable operation;

The module should be as far away as possible from the power supply, transformers, high-frequency wiring and
other parts with large electromagnetic interference;

Bottom Layer High-frequency digital routing, high-frequency analog routing, and power routing must be avoided
under the module. If it is necessary to pass through the module, assume that the module is soldered to the Top Layer,
and the copper is spread on the Top Layer of the module contact part(well grounded), it must be close to the digital
part of the module and routed in the Bottom Layer;

Assuming the module is soldered or placed over the Top Layer, it is wrong to randomly route over the Bottom
Layer or other layers, which will affect the module's spurs and receiving sensitivity to varying degrees;

It is assumed that there are devices with large electromagnetic interference around the module that will greatly
affect the performance. It is recommended to keep them away from the module according to the strength of the
interference. If necessary, appropriate isolation and shielding can be done;

Содержание E32-400T20S

Страница 1: ...1 E32 900M30S SX1276 868 915MHz SPI SMD Wireless Module ...

Страница 2: ... Size and pin definition 6 4 Basic operation 7 4 1 Hardware design 7 4 2 Programming 8 5 Basic application 9 5 1 Hardware design and circuit schematic diagram 9 6 FAQ 9 6 1 Communication range is too short 9 6 2 Module is easy to damage 10 6 3 BER Bit Error Rate is high 10 7 Production guidance 11 7 1 Reflow soldering temperature 11 7 2 Reflow soldering curve 11 8 E32 series 12 9 Antenna recommend...

Страница 3: ...oduction use modification or disclosure to third parties of this document or any part thereof without the express permission of EBYTE is strictly prohibited The information contained herein is provided as is and EBYTE assumes no liability for the use of the information No warranty either express or implied is given including but not limited with respect to the accuracy correctness reliability and ...

Страница 4: ...pport data transmission rate between 0 018K and 37 5Kbps in LoRaTM mode Support data transmission rate of up to 300kbps in FSK mode Support for multiple modulation mode LoRaTM FSK GFSK MSK GMSK OOK Large FIFO capacity support 256Byte data cache Support 3 3V 5 5V power supply power supply over 5 V can guarantee the best performance Industrial grade standard design support 40 85 C for working over a...

Страница 5: ...tly increase Due to its advanced LoRaTM modulation technology its anti interference performance and communication distance are far superior to the current FSK and GFSK modulation products This module is mainly aimed at intelligent home wireless meter reading scientific research and medical treatment and medium and long distance wireless communication equipment As the RF performance and component s...

Страница 6: ...5 5 5 5 5 V ensures output power Communication level V 3 3 Operating temperature 40 85 Industrial grade Operating frequency MHz 850 868 915 931 Power Consump tion TX current mA 650 RX current mA 19 Sleep current μA 2 Max TX power dBm 30 Receiving sensitivity dBm 123 124 125 Air data rate is 1 2 kbps Main parameter Description Remark Reference distance 10km Test condition clear and open area antenn...

Страница 7: ...RXEN Input RF switch receiving control pin connected to external MCU IO high level effective 7 TXEN Input RF switch receiving control pin connected to external MCU IO high level effective 8 DIO2 Input Output General IO port see SX1276 manual for details 9 VCC Power supply range 3 3 5 5V external ceramic filter capacitor is recommended 10 VCC Power supply range 3 3 5 5V external ceramic filter capa...

Страница 8: ...the recommended supply voltage if exceeding the maximum the module will be permanently damaged Please check the stability of the power supply Voltage can not fluctuate greatly and frequently When designing the power supply circuit for the module it is often recommended to reserve more than 30 of the margin so the whole machine is beneficial for long term stable operation The module should be as fa...

Страница 9: ...tal case which will cause the transmission distance to be greatly weakened 4 2 Programming The core of this module is SX1278 SX1276 PA LNA its driving method is completely equivalent to SX1278 SX1276 the user can operate according to the SX1278 SX1276 chip manual DIO0 DIO1 DIO2 DIO3 DIO4 and DIO5 are general I O ports which can be configured into a variety of functions See SX1278 manual for detail...

Страница 10: ...bsorb and reflect wireless radio wave so the performance will be poor when testing near ground Sea water has great ability in absorbing wireless radio wave so performance will be poor when testing near the sea The signal will be affected when the antenna is near metal object or put in a metal case Power register was set incorrectly air data rate is set as too high the higher the air data rate the ...

Страница 11: ... electrostatic susceptibility Please ensure the humidity is within limited range some parts are sensitive to humidity Please avoid using modules under too high or too low temperature 6 3 BER Bit Error Rate is high There are co channel signal interference nearby please be away from interference sources or modify frequency and channel to avoid interference SPI clock waveform is not standard check wh...

Страница 12: ...n96 5 Ag3 Cu0 5 Preheat Temperature min Tsmin 100 150 Preheat temperature max Tsmax 150 200 Preheat Time Tsmin to Tsmax ts 60 120 sec 60 120 sec Average ramp up rate Tsmax to Tp 3 second max 3 second max Liquidous Temperature TL 183 217 Time tL Maintained Above TL 60 90 sec 30 90 sec Peak temperature Tp 220 235 230 250 Aveage ramp down rate Tp to Tsmax 6 second max 6 second max Time 25 to peak tem...

Страница 13: ...commendation The antenna is an important role in the communication process A good antenna can largely improve the communication system Therefore we recommend some antennas for wireless modules with excellent performance and reasonable price Model No Type Frequency Gain Hright Cable Interface Function feature Hz dBi mm cm TX915 JZ 5 Rubber antenna 915M 2 0 50 SMA J Short straight omnidirectional TX...

Страница 14: ...scription Issued by 1 0 2021 5 07 Initial version Linson About us Technical support support cdebyte com Documents and RF Setting download link www ebyte com Thank you for using Ebyte products Please contact us with any questions or suggestions info cdebyte com Phone 86 028 61399028 Web www ebyte com Address B5 Mould Park 199 Xiqu Ave High tech District Sichuan China ...

Отзывы: