ADDH\ADDL of Repeater 1 are 08

33 respectively.

So the data sent by node 1 (08) can be forwarded to node 2 (33)
Meanwhile,node 1 and node 2 have the same address, so the data transmitted by node 1 can be received by node 2.

Secondary repeater

ADDH\ADDL of Repeater 2 are 33

05 respectively.

Therefore, Repeater 2 can forward the data of Repeater 1 to the network NETID: 05.
Thus node 3 and node 4 can receive the data from node . Node 4 outputs data normally, but no ourput from Node3 because Node 3 has

a different address from Node 1.

Two-way repeater

As shown in below

The data sent by Node 1 can be received by Node 2 and Node 4; The data sent by by Node 2 and Node 4 can also

be received by Node 1.

Chapter 10 Configuration instructions on computer

The following figure is the display interface of E29-400T22S configuration on computer. User can switch to the command mode

through M0, M1, and quickly configure and read the parameters on computer. (

配置软件要英文界面

)

Содержание E29-T Series

Страница 1: ...E29 T Series User Manual PAN3031 433 470MHz 160mW Wireless Module...

Страница 2: ...eset 12 5 6 AUX Description 12 5 6 1 Indication of UART Output 12 5 6 2 Indication of Wireless Transmitting 13 5 6 3 The module is being configured 13 5 6 4 Notes for AUX 13 Chapter 6 Working Mode 14...

Страница 3: ...d 25 12 3 BER Bit Error Rate is high 26 Chapter 13 Welding Work Instructions 27 13 1 Reflow soldering temperature 27 13 2 Reflow soldering curv 28 Chatper 14 Retaled series 28 Chapter 15 Antenna recom...

Страница 4: ...s in estoppel or other ways whether express or implied The test data obtained in the article are all obtained by the Ebyte laboratory and the actual results may vary slightly We hereby declared that a...

Страница 5: ...t service is also available 1 E29 400T22S 2 E29 400T22D 1 2 Features Support AT command more convenient for use Support IAP upgrade more convenient to update firmware ChirpIoT based modulation method...

Страница 6: ...esign supporting long term use at 40 85 1 3 Application Home security alarm and remote keyless entry Smart home and industrial sensors Wireless alarm security system Building automation solutions Wire...

Страница 7: ...mode Sleep current uA 2 2 software shutdown Temperature Operating temperature 40 85 Industrial grade Storage temperature 40 85 Industrial grade 2 3 Hardware Parameters Hardware parm Model No Remark E...

Страница 8: ...r 3 Size and Pin Definition 3 1 E29 400T22S Dimension and Pin definition Pin No Pin Name Pin Direction Pin Function 1 GND Module ground 2 GND Module ground 3 GND Module ground 4 GND Module ground 5 M0...

Страница 9: ...module For user to wakes up the external MCU and it outputs low level during power on self check initialization can be left floating 10 VCC Module power positive reference voltage range 2 6 5 5V DC 1...

Страница 10: ...dicate the working status of the module For user to wakes up the external MCU and it outputs low level during power on self check initialization can be left floating 6 VCC Power supply Module power po...

Страница 11: ...e Electronic Technology Co Ltd E29 400TXXX product data sheet Copyright 2012 2023 Chengdu Ebyte Electronic Technology Co Ltd 11 Chapter 5 Function Description 5 1 Fixed Transmission 5 2 Broadcasting T...

Страница 12: ...listening is realized 5 5 Module Reset After the module is powered on AUX will immediately output low level perform hardware self check and set the working mode according to user parameters During th...

Страница 13: ...ser continuously sends data less than 700 bytes it won t overflow When AUX 0 the buffer is not empty It means data in the module s internal 700byte buffer has not been written to the wireless chip and...

Страница 14: ...are four working modes which are set by M1 and M0 the details are as follows Mode 0 3 M1 M0 Description Remark 0 Transmission Mode 0 0 UART and wireless channel are open transparent transmission is o...

Страница 15: ...of fast switching For example switching from the transmit mode to the receive mode the user MCU can also enter sleep before the mode switch and use the external interrupt function to acquire the AUX...

Страница 16: ...d write control 7 1 Command format In configuration mode mode 2 M0 0 M1 1 the list of supported commands are as follows only 9600 8N1 format is supported when setting No Command format Description 1 S...

Страница 17: ...Remark 00H Read Write ADDH ADDH default 0 High byte and low byte in the module address Note When the module address is FFFF it can be used as the broadcast and listening address that is the module wi...

Страница 18: ...mmands 1 DCDC mode reduces power consumption by sacrificing sensitivity 2 LDO mode improves sensitivity by sacrificing power consumption 3 It is recommended to use DCDC mode for battery powered device...

Страница 19: ...dule receiving and transmitting functions are turned on and a wake up code of a period of time is added when transmitting data 2 1 0 WOR cycle time Below description is valid for Mode 1 only Cycle tim...

Страница 20: ...Example description AT UART baud parity Set baud rate and parity AT UART 3 0 Set baud rate 9600 8N0 AT RATE rate Set air data rate AT RATE 7 Set air data rate 16 4K AT PACKET packet Set packet length...

Страница 21: ...Query RF Power Mode AT LDO 0 Return DCDC RF Power Mode AT ADDR Query module address AT ADDR 1234 Return module address 1234 AT CHANNEL Query module working channel AT CHANNEL 23 Return working frequen...

Страница 22: ...it will enter the upgrade mode infinitely even if it is restarted After entering the upgrade mode the baud rate will automatically switch to 115200 until it exits automatically during which there wil...

Страница 23: ...eater 2 can forward the data of Repeater 1 to the network NETID 05 Thus node 3 and node 4 can receive the data from node Node 4 outputs data normally but no ourput from Node3 because Node 3 has a diff...

Страница 24: ...dress of Repeater R is 0X020A in hex and it need to be converted to decimal Chapter 11 Hardware design It is recommended to use a DC stabilized power supply The power supply ripple factor is as small...

Страница 25: ...line uses a 5V level a 1k 5 1k resistor must be connected in series 5V communication level is not recommended there is still a risk of damage The mounting structure of antenna has a great influence o...

Страница 26: ...e that the humidity during installation and in use should not be too high some components are sensitive to humidity Please avoid using modules at too high or too low temperature if there is no special...

Страница 27: ...p 3 s Maximum 3 s Maximum Liquidous Temperature TL 183 217 Time tL Maintained Above 60 90s 60 90s Package peak temperature Tp Should not exceed the temperature indicated on the product s label of Mois...

Страница 28: ...terface E22 230T22S SX1262 230M 22 5 SMD 16 26 TTL E22 230T30S SX1262 230M 30 10 SMD 20 40 5 TTL E22 400T22S SX1262 433 470M 22 5 SMD 16 26 TTL E22 400T30S SX1262 433 470M 30 10 SMD 20 40 5 TTL E22 90...

Страница 29: ...Short straight omnidirectional TX433 JZG 6 Rubber antenna 433M SMA J 2 5 62 Short straight omnidirectional TX433 JW 5 Rubber antenna 433M SMA J 2 0 50 Flexible omnidirectional TX433 JWG 7 Rubber anten...

Страница 30: ...e Electronic Technology Co Ltd E29 400TXXX product data sheet Copyright 2012 2023 Chengdu Ebyte Electronic Technology Co Ltd 30 Chapter 16 Bulk Packing 15 1 E29 400T22S bulk packing 15 1 E29 400T22D b...

Страница 31: ...022 12 12 Initial version Weng About us Technical support support cdebyte com Documents and RF Setting download link https www cdebyte com Thank you for using Ebyte products Please contact us with any...

Отзывы: