Chengdu Ebyte Electronic Technology Co.,Ltd.
E180-ZG120B User Manual
Copyright ©2012–2020, Chengdu Ebyte Electronic Technology Co.,Ltd.
15
devices with signal strength greater than -40dBm will be scanned), if scanning more than two target devices will affect
the success rate of touch link
(3) Secondly, after the initiator scans the target device, if it initiates the touch link for the first time, it initiates a
request to create a new network to the target; if the touch link has succeeded before, it initiates the touch link to the target.
Network request.
(4)
Finally, the target responds to the initiator's request to create a new network or join the touch link network.
After the above steps, a new ZLL touch link network has been completed. There may only be one initiator in
network, and other nodes are all targets. Before the touch link, the initiator must first clear the previously added network.
During the touch link process, only one device is close to one device at a time. The touch link network can be used
without coordinator and only requires end-device and router, so that the network is simpler and more convenient, and is
widely used in the field of lighting control.
6.4 Functional parameter description
The module provides a wide range of configurable parameters that can be flexibly adapted to the actual application
needs to build different forms of network.
Configuration
information
Property
Parameter
range
Function Description
PANID
Read/write
0x0000
~
0xFFFF
The PANID is the network identifier of ZIGBEE and is used to
determine the identity of the network to which it belongs. All
devices in the same network must have the same PANID. When
the end-device or router is configured as 0xFFFF, it can join any
network that already exists on the same channel
;
Local network
address
Read
0x0000
~
0xFFFF
It is used to distinguish each node in network. Each device is in
the same network. The local network address must be unique.
When the network is not added, the network address of the device
is 0xFFFF. After joining, the short address of the device is
allocated by the coordinator. The coordinator is fixed at: 0x0000;
Network status
Read
0
、
1
、
2
、
3
、
4
Indicates the network status of the current device, including no
network, currently joining the network, successfully joining the
network, having the network but losing the parent node, leaving
the current network, and so on;
Target network
address
Read/write
0x0000
~
0xFFFF
The current device communication destination (short address) can
be switched at any time through configuration commands;
Local MAC
address
Read
64bitMAC
Module factory MAC address, user can not be changed
Target
MAC
address
Read/Write
64bitMAC
In fixed-point mode, use long address to send;
Device type
Read/Write
C
、
R
、
E
、
S
They are: coordinator, router, end-device and sleep end-device;
Channel
Read/Write
CH11
~
26
The physical channel through which ZIGBEE works;
Transmit mode
Read/Write
0
、
1
、
2
、
3
、
4
、
5
The transmission modes of the configuration module are: broadcast mode,
multicast mode, short address on demand mode, long address on demand
mode, protocol on demand, and protocol multicast. For details, please see