Chengdu Ebyte Electronic Technology Co.,Ltd.
E180-ZG120A User Manual
Copyright ©2012–2019, Chengdu Ebyte Electronic Technology Co.,Ltd.
1
Read target network group
number
24
Send
:
FE 01 24 FF
Return
:
FB 24 Dec_netid
Send
:
FE 01 24 FF
Return
:
FB 24 00
Read target long address
25
Send
:
FE 08 25 FF
Return
:
FB 25 Dec_mac
Send
:
FE 08 25 FF
Return
:
FB 25 0A 1C 21
FE FF 57 B4 14
Read
system
transmitting
mode
26
Send
:
FE 01 26 FF
Return
:
FB 26 send_mode
Send
:
FE 01 26 FF
Return
:
FB 26 02
Read data output mode
27
Send
:
FE 01 27 FF
Return
:
FB 27 out_mode
Send
:
FE 01 27 FF
Return
:
FB 27 00
Read
centralized
network
open time
28
Send
:
FE 01 28 FF
Return
:
FB 28 net_opentime
Send
:
FE 01 28 FF
Return
:
FB 28 FF
The parent node loses the
network
reconnection
period
29
Send
:
FE 01 29 FF
Return
:
FB 29
net_rejoinperiod
Send
:
FE 01 29 FF
Return
:
FB 29 05
The maximum number of
times the parent node lost
network reconnection
30
Send
:
FE 01 30 FF
Return
:
FB 30
net_rejoincount
Send
:
FE 01 30 FF
Return
:
FB 30 05
Read
wireless
configuration ID
31
Send
:
FE 02 31 FF
Return
:
FB 31 header
Send
:
FE 02 31 FF
Return
:
FB 31 A8 8A
Read all device data
FE
Send
:
FE 2F FE FF
Return
:
FB FE all_info
Send
:
FE 2F FE FF
Return
:
FB FE 03 02 FE 5B
F6 FA 1F 1C 21 FE FF 57
B4 14 00 00 0C 46 0C FE
FF 9F FD 90 01 0B 0A 09
54 00 00 00 0A 1C 21 FE FF
57 B4 14 02 00 FF 05 05 A8
8A
Read remote/local GPIO level
20
Send
:
FE 03 20 GpioId FF
Return
:
FB 20 GpioId In/Out
level
Send
:
FE 03 20 00 FF
Return
:
FB 20 00 01 01
Read remote/local PWM state
21
Command
:
FE 06 21 PWMId
FF
Return
:
FB 21 PWMId
start/stop
Period Period duty
duty
Send
:
FE 06 21 00 FF
Return
:
FB 21 00 01
0A 3E 63 50
Read local /remote ADC state
22
Command
:
FE 03 22 adcid FF
Return
:
FB 22 adcid voltage1
voltage2
Send
:
FE 03 22 00 FF
Return
:
FB 22 00 0C E4
Number
of end-device
nodes reading the parent
node
32
Command
:
FE 01 32 FF
Return
:
FB 32 child_count
Send
:
FE 01 32 FF
Return
:
FB 32 0A
Read the parent node's
33
Command
:
FE 0E 33 FF
Send
:
FE 0E 33 FF