When the node is powered on, it will join the network (if there is no network status) or restore the network (if there is a network
without parent node status) in the Rejoin period cycle. When the node detects that the parent node is offline during operation, it
will reconnect with the “Rejoin period” period.
When the parameter is 254, it means that no reconnection or periodic network screening will be performed.
6.6.17 Maximum number of attempts to reconnect
Read instruction format:
command format
command example
send
:
FE 01 30 FF
return
:
FB 30 net_rejoincount
send
:
FE 01 30 FF
return
:
FB 30 05
Configuration command format
:
command format
command example
send
:
FD 01 30 time FF
return
:
FA 30
send
:
FD 01 30 05 FF
return
:
FA 30
Rejoin maxcount: (1~254) The maximum number of reconnections ranges from 1 to 254 times, and the default is 10
After the node loses its parent node during operation or has a network without a parent node, try the maximum number of rejoins
after power-on. If the previous network has not been restored, the previous network information will be cleared, and the new
network will be periodically scanned to join with the Rejoin period. Scanning for a new network consumes more power than
restoring the previous network.
When the parameter is 254, it means that when there is a network and no parent node, the reconnection is always performed and
the action of clearing the network is not performed.
6.6.18 Wireless remote configuration ID
Read instruction format:
command format
command example
send
:
FE 02 31 FF
return
:
FB 31 header
send
:
FE 02 31 FF
return
:
FB 31 A8 8A
Configuration command format
:
command format
command example
send
:
FD 02 31 header FF
return
:
FA 31
send
:
FD 02 31 A8 8A FF
return
:
FA 31