Chengdu Ebyte Electronic Technology Co., Ltd.
E180-Z5812SP Product Manual
Copyright ©2012–2019,
Chengdu Ebyte Electronic Technology Co., Ltd.
24
return
:
FA 09
return
:
FA 09
group
:
Group number range 0x01
~
0xFE (default 1)
6.6.11 Network Channels
Read instruction format:
command format
command example
send
:
FE 01 0A FF
return
:
FB 0A channel
send
:
FE 01 0A FF
return
:
FB 0A 0B
Configuration command format
:
command format
command example
send
:
FD 01 0A channel FF
return
:
FA 0A
send
:
FD 01 0A 0B FF
return
:
FA 0A
channel
:
Channel range 0x0B(11)
~
0x1A(26) (default 11 channels), 0xFF means full channel scan.
Channel The parameters need to be configured before accessing the network.
6.6.12 Transmit power
Read instruction format:
command format
command example
send
:
FE 01 0B FF
return
:
FB 0B txpower
send
:
FE 01 0B FF
return
:
FB 0B 0A
Configuration command format
:
command format
command example
send
:
FD 01 0B txpower FF
return
:
FA 0B
send
:
FD 01 0B 0A FF
return
:
FA 0B
txpower
:
The transmit power level (00) needs to be configured before accessing the network.
txpower
Transmit power
level
(
dbm
)
txpower
Transmit power level
(
dbm
)
00
11.76
06
10.33
01
11.66
07
10.04
02
11.31
08
9.73
03
11.09
09
9.38
04
10.82
0A
9.03
05
10.54