Chengdu Ebyte Electronic Technology Co.,Ltd.
E104-BT40 User Manual
Copyright ©2012–2019
,
Chengdu Ebyte Electronic Technology Co.,Ltd.
4-22
6.4.16 AT+P11 P11 Input
Command
Response
Query
AT+P11?
+OK=[para]
Parameter
para(ASCII)
Description
0
Low level
1
High level(Default)
6.4.17 AT+PWM2 PWM2 Output
Command
Response
Setting
AT+PWM2 =[para]
+OK:Success
+ERR=[NUM]:Error
Parameter
para:0~100(ASCII)
0 turn off PWM(Default)
Description
Takes effect immediately, save when power off. The parameter output PWM will maintain at the next power-on.
Example
Command
:
AT+PWM2=0
Response
:
+OK
6.4.18 AT+PWM3 PWM3 Output
Command
Response
Setting
AT+PWM3 =[para]
+OK:Success
+ERR=[NUM]:Error
Parameter
para:0~100(ASCII)
0 Turn off PWM(Default)
Description
Takes effect immediately, save when power off. The parameter output PWM will maintain at the next power-on.
Example
Command
:
AT+PWM3=0
Response
:
+OK