Chengdu Ebyte Electronic Technology Co.,Ltd.
E104-BT40 User Manual
Copyright ©2012–2019
,
Chengdu Ebyte Electronic Technology Co.,Ltd.
4-21
6.4.13 AT+P02 P02 Output
Command
Response
Setting
AT+P02=[para]
+OK:Success
+ERR=[NUM]:Error
Parameter
para(ASCII)
Description
0
Low level(Default)
1
High level
Description
1.Takes effect immediately, save when power off
2.After the next power-on, the IO remains at this level
Example Command
:
AT+P02=1
Response
:
+OK
6.4.14 AT+P03 P03 Output
Command
Response
Setting
AT+P03=[para]
+OK:Success
+ERR=[NUM]:Error
Parameter
para(ASCII)
Description
0
Low level(Default)
1
High level
Description
1.Takes effect immediately, save when power off
2.After the next power-on, the IO remains at the set level
Example
Command
:
AT+P03=1
Response
:
+OK
6.4.15 AT+P10 P10 Input
Command
Response
Query
AT+P10?
+OK=[para]
Parameter
para(ASCII)
Description
0
Low level
1
High level(Default)