0xFA
Assign netkey failure
0xF9
Bind Appkey overtime
0xF8
Bind Appkey failure
0XF7
Last networking not
finished
1. NetKey configuration
Key is for network ID assigned by provisioner
,
format is as follows
Operation
code
Parameter
Request
0x00
Configure 16 bytes of NetKey data
Respond
0x00
Return configured 16 bytes of NetKey data
For
example
Request
:
12 C0 00 11223344556677889900112233445566
Respond
:
12 40 00 11223344556677889900112233445566
Notes
:
1
、
suitable for
E104-BT10-G
2
、
After configuration, the system will restart once
2.To read NetKey
Operation
code
Parameter
Request
0x01
/
Respond
0x01
Return configured 16 bytes of NetKey data
For
example
Request
:
02 C0 01
Respond
:
12 40 01 11223344556677889900112233445566
Notes
:
This is for reading configured NetKey
3.AppKey configuration
Operation
code
Parameter
Request
0x02
Configure 16 bytes of AppKey data
Respond
0x02
Return configured 16 bytes of AppKey data
For
example
Request
:
12 C0 02 11223344556677889900112233445566
Respond
:
12 40 02 11223344556677889900112233445566
Notes
:
1
、
Suitable for
E104-BT10-G
2
、
After configuration, the system will restart once