Chengdu Ebyte Electronic Technology Co., Ltd
E104-BT10-IPX User Manual
Copyright ©2012–2019
,
C
hengdu Ebyte Electronic Technology Co., Ltd
2-4
2
、
Specification and Parameter
2.1 Limit parameter
Main Parameter
Performance
Note
Min
Max
Voltage supply [V]
0
3.6
Voltage over 3.6V will cause permanent damage
to module
Blocking power [dBm]
-
10
Chances of burn is slim when modules are used in
short distance
Operating temperature [
℃
]
-40
+85
-
2.2 Operating parameter
Main parameter
Performance
Note
Min
Typ
Max
Voltage supply [V]
1.9
3.3
3.6
≥3.3 V ensures output power
Communication level [V]
-
3.3
-
For 5V TTL, it may be at risk of burning down
Operating temperature [
℃
]
-40
-
+80
Frequency [MHz]
2400
2483.5
ISM band
Power
consumption
Transmitting current
(
mA
)
-
29
-
Instant power consumption
Receiving current
(
mA
)
-
29
-
-
Stand-by current(uA)
1.6
Transmitting power [dBm]
-
8.0
-
-
Receiving sensitivity [dBm]
-88
-92
-97
Air data rate is 1Mbps
Communicati
on rate
GFSK
(
bps
)
--
1M
--
-
Main parameter
Description
Note
Distance
50m
Test condition
:
clear and open area, antenna height: 2.5m
,
air data rate:
1Mbps
FIFO
80byte
Max. Transmitting length per packet
Crystal oscillator
16MHz
-
Modulation
GFSK
GFSK Mode
Package
SMD
-
Connector
1.27mm
-
Interface
UART
4800
~
230400bps
Size