![Ebyte E103-W07 Скачать руководство пользователя страница 21](http://html.mh-extra.com/html/ebyte/e103-w07/e103-w07_user-manual_530473021.webp)
Chengdu Ebyte Electronic Technology Co.,Ltd.
E103-W07 User Manual
Copyright ©2012–2021
,
Chengdu Ebyte Electronic Technology Co.,Ltd.
20
Description
1. Restart to take effect, save when power off;
2. In a mesh network with a router, the channel depends on the channel of the router AP; in a mesh network without a
router, the channel must be set.
3. In a MESH grid with a router, the channel switch should be set to 0 when the channel of the router AP is not clear,
otherwise the module cannot join the Mesh network because there is no designated AP in this channel.
Example
Get the mesh channel:
AT+MECHANNEL?
Module response:
+ MECHANNEL:1,0
AT+MECHANNEL=7,1
5.5.5 AT+MECAPACITY MESH network capacity
Instruction
Answer
Inquiry
AT+MECAPACITY?
+MECAPACITY:
[ApConnectNum],[LayersMax],[CapacityNum]
Setting
AT+MECAPACITY=[ApConnectNum],[LayersMax],[
CapacityNum]
+OK
Success
+ERR:[NUM]
Error
Parameter
ApConnectNum
The maximum number of child nodes that can be connected. Value range:
<= 10, default: 6
LayersMax
Mesh network layer number. Value range: 2~25. Default: 6
CapacityNum
The maximum number of nodes in a Mesh network. Value range: <= 1000,
default: 300
Description
1.
Restart to take effect, save when power off;
2.
The MESH network determines the network capacity based on the values of ApConnectNum and LayersMax.
The MESH network is a tree network. If the number of layers is 3 and the number of child nodes is 3, the
theoretical network capacity: 3^0+3^1+3^2=13. If the value of CapacityNum is set to <13, then the network
capacity of the most network is determined by CapacityNum; if At this time CapacityNum>13, then the
network capacity is determined according to the calculation result 13.
Example
AT+MECAPACITY=2,3,50
Set the result to 2, 3, 50
5.5.6 AT+METYPE The type of node in the network
Instruction
Answer
Inquiry
AT+METYPE?
+METYPE:[ type]
Setting
AT+METYPE=[type]
+OK
Success
+ERR:[NUM]
Error
Parameter
type
description
0(default)
MESH_IDLE(Not joined the network)
1
MESH_ROOT(Root node)
2
MESH_NODE(node)