The relationship between power and current
is non-linear, and the power supply has the
highest efficiency at maximum power;
The current will not decrease in the same
proportion as the power decreases.
05H
Read/Write
REG2
Channel Control (CH)
1
Actual frequency =
433MHz
06H
Read/Write
REG3
7 Enable RSSI byte
After being enabled, the DTU receives
wireless data and outputs it through the serial
port TXD, followed by an RSSI strength byte.
0 Disabled (default)
1 Enable
6 Transfer method
During fixed-point transmission, the DTU
will recognize the three bytes of serial data
as: address high + address low + channel, and
use it as a wireless transmission target.
0 Transparent transmission (default)
1 Fixed point transmission
5 Relay function
After the relay function is enabled, if the
target address is not the DTU itself, the DTU
will start a forwarding;
In order to prevent data from returning, it is
recommended to use it in conjunction with
the fixed-point mode; that is, the destination
address is different from the source address.
0 Disable relay function (default)
1 Enable relay function
4 LBT Enable
After enabling, monitoring will be conducted
before wireless data transmission, which can
avoid interference to a certain extent, but may
cause data delay;
The maximum stay time of LBT is 2 seconds,
and it will be issued forcibly when it reaches
2 seconds.
0 Disabled (default)
1 Enable
3 WOR Mode send and receive control
Only valid for mode 1;
After the WOR receiver receives the wireless
data and outputs it through the serial port, it
will wait 1000ms before entering the WOR
again. The user can input the serial port data
during this period and return it via wireless;
Each serial port byte will be refreshed for
1000ms;
The user must initiate the first byte within
1000ms.
0
WOR receiver (default)
The transceiver is turned on, and when
transmitting data, a wake-up code for a certain
period of time is added.
1
WOR transmitter
The DTU cannot transmit data, and it works in
WOR monitoring mode. The monitoring period is
shown below (WOR period), which can save a lot
of power consumption.
2
1
0
WOR Cycle
Only valid for mode 1;
Cycle T= (1+WOR)*500ms, the maximum is
4000ms, the minimum is 500ms;
The longer the WOR monitoring interval
period, the lower the average power
consumption, but the greater the data delay;
Both sender and receiver must agree (very
important)
0
0
0
500ms
0
0
1
1000ms
0
1
0
1500ms
0
1
1
2000ms
1
0
0
2500ms
1
0
1
3000ms
1
1
0
3500ms