BLACKMER BYPASS VALVES
967020
INSTRUCTIONS NO. 551-E00
INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS
EBSRAY MODEL: RV18
Section
Effective
Replaces
551
Aug 2015
Nov 2014
RV18CBS2, RV18CBS3, RV18VRS10, RV18VRS14, RV18VRS19
TABLE OF CONTENTS
Page
GENERAL
Description ............................................................ 2
Nameplate
codes .................................................. 2
INSTALLATION
Piping .................................................................... 3
Checking the External Bypass Valve Pressure ..... 3
Bypass Valve Adjustment ...................................... 4
Operational Checks ............................................... 4
MAINTENANCE
Periodic Inspection ................................................... 4
Preparation for Disassembly .................................... 5
Disassembly ............................................................. 5
Inspection ................................................................. 5
Reassembly ............................................................. 5
PARTS DESIGNATION
................................................... 6
Numbers in parentheses following individual parts indicate
reference numbers on Parts Designation page.
Blackmer instruction manuals and parts lists may be obtained
from Blackmer's website (www.blackmer.com) or by
contacting Blackmer Customer Service.
SAFETY DATA
This is a SAFETY ALERT SYMBOL.
When you see this symbol on the product, or in the manual,
look for one of the following signal words and be alert to the
potential for personal injury, death or major property
damage
Warns of hazards that WILL cause serious personal injury,
death or major property damage.
Warns of hazards that CAN cause serious personal injury,
death or major property damage.
Warns of hazards that CAN cause personal injury
or property damage.
NOTICE:
Indicates special instructions which are very
important and must be followed.
NOTICE:
Blackmer external bypass valves MUST only be
installed in systems which have been designed by
qualified engineering personnel. The system MUST
conform to all applicable local and national
regulations and safety standards.
This manual is intended to assist in the installation
and operation of Blackmer bypass valves, and MUST
be kept with the bypass valve.
Blackmer bypass valve service shall be performed by
qualified technicians ONLY. Service shall conform to
all applicable local and national regulations and
safety standards.
Thoroughly review this manual, all Instructions and
hazard warnings, BEFORE performing any work on
the Blackmer bypass valves.
Maintain ALL system and Blackmer liquefied gas
pump operation and hazard warning decals.