SIM Card 1 PIN
8.2.5.
As a device operates via UMTS network, SIM card is indispensable and it may be
received from phone operator. Before the first use PIN code of SIM card shall be
programmed for operation in given communicator. PIN code is indispensable for
automatic system launching. In case of card without PIN code, it is possible to enter
any value e.g. 0000.
If you enter wrong PIN number after inserting card and switching on communicator,
the system will not launch and you may be able to use card after entering PUK card
only (with use of any GSM mobile phone).
Factory setting of PIN in communicator is
1111
.
Factory settings restoration lock
8.2.6.
The function “Defaults restoral lock” allows the user to turn off the ability to restore
the factory-default installer’s code. However, when restoring default settings using
the Configuration, when the "Restore device’s default settings" option is selected, a
window with a request to enter the installer’s code or service code (ATS) will appear.
When this function is turned on, the Manufacturer recommends the installer’s code
and service code (ATS) are changed.
Server communication parameters lock
8.2.7.
After checking that option resetting to default settings and changing:
• service code (ATS),
server phone number,
primary server address
backup server address
• Ethernet parameters (address, mask, gate)
• APN, user ID, user password
• primary server port
• secondary server port
• SMS encryption key
• TCP/IP encryption key
• DNS server addresses
turning on/off “Firmware Change Code”
turning on/off “Communication settings lock” option
will require service code (ATS) knowledge! In addition, remote commands
for setting the above parameters will be blocked.
As a result, it will be
impossible to register communicator in other monitoring station without
authorization.
On the other hand, installer will be able to:
• change parameters related to: partitions, inputs, outputs, SMS notification and
certain system options,
• send it to communicators,
• update firmware
• read settings saved on the device,
• save communicators settings to .emi file.
Default service code (ATS) is 0000 – it is recommended to change it to unique,
preferably 7-digit code.
NOTE!