CPX200N ALARM CONTROL UNIT – INSTALLER MANUAL
22 / 106
5.
ALARM CONTROL UNIT HANDLING
5.1.
ARMING THE SYSTEM
1.
Enter your code and press
. 3 beeps will confirm the code.
Note: If incorrect code is entered the keypad will emit long constant
sound. Repeat the arming process by entering the correct code.
2.
Leave the facility before the time for leaving expires. That state is indicated by
intermittent sound and quick flashing the ARMED LED on the keypad until the system
gets fully armed. If the chirps are activated the arming will be confirmed by one chirp of
siren.
Note: If the partition is not plugged any zones and/or outputs, the
partition is not armed.
5.2.
ARMING THE SYSTEM WITH FAULT
If during the arming any faults are present in the system, the keypad will indicate it with
flashing ARMED and SYSTEM LEDs and long constant sound audio signal. LEDs 1 to 8 will
indicate which system errors are present. That state will maintain for 10 seconds. If there is
no possibility to quickly remove faults, press
to arm the system. Pressing
will
cancel the arming process.
Note: Remove the causes of faults as soon as possible.
Error codes:
1 – Damage or disruption of detector
2 – Damage of signalling device or signalling device active
3 – Damage of internal connection or sabotage
4 – AC power supply damage
5 – Battery damage
6 – ATS damage
8 – Other damages
5.3.
DISARMING THE SYSTEM
1.
Enter the facility through the entrance door. Intermittent sound and slow flashing of
ARMED LED on the keypad will remind of the need to disarm the system before the delay
time for entrance expires.
2.
Enter the code and press
. 3-tone beep of the keypad will confirm the correct code
input. The partition the user has access to will be disarmed. If the chirps are activated
the disarming will be confirmed by two chirps of siren. If the user has access to all