background image

 
AVA PRO - Assembly instructions for the CPX300W alarm control panel

  

5

 

/

 

23

 

2.

 

GENERAL INFORMATION 

CPX300W is a simple alarm control panel, which can be extended by 4 additional modules, allowing a 
significant  extension  of  functionality.  Thanks  to  this  structure,  the  user  can  individually  choose 
equipment and create a system that fully satisfies his needs and expectations. 

A  well-thought-out  arrangement  of  components  and  an  intuitive  dedicated  EBS  Config  2.0  application 
for  device  programming  make  the  installation  quick  and  pleasant,  and  the  configuration  itself  is  very 
simple and trouble-free. 

2.1.

 

System properties 

1.

 

Available data transmission channels:

 

 

Data transmission via the GSM module, 

 

Data transmission via a wired Ethernet network, 

 

Data transmission via a wireless Wi-Fi network. 

2.

 

Wireless two-way system components:

 

 

KP3W - keypad, 

 

MC-30 - magnetic contact with an additional input, 

 

PIR-30 - motion detector, 

 

PIRC-AM-30 - motion detector with a camera, 

 

RC-30 - remote control, 

 

STAG-30 – touchless user identifier AVA KEY,  

 

BM8000PLx-C3W – visual / audible wireless siren (support from firmware version 3.1.6). 

3.

 

Wireless one-way components cooperating with the system.

 

Installation of the MOD-RF433 module on the CPX300W motherboard allows you to expand the 
supported devices by the following list: 

 

MC-10 - magnetic contact, 

 

MC-11 - magnetic contact with an additional input, 

 

PIR-10 - motion detector, 

 

PIR-11 - motion detector (PET), 

 

SD-20 - smoke detector, 

 

FL-10 – water flood detector, 

 

GS-21 - gas detector (carbon monoxide and natural gas), 

 

GS-22 - gas detector (carbon monoxide and propane-butane), 

 

MD-10 - movement detector, 

 

GB-10 - glass break detector. 

4.

 

Modules:

 

 

MOD-GSM-2G  /  MOD-GSM-3G  (including  2  nano  SIM  holders)  -  cellular  network 
communication module 2G or 3G, 

 

MOD-ETH  -  wired  Ethernet  module  /  MOD-WiFi  communication  module  –  wireless  Wi-Fi 
module, 

 

MOD-RF433– 433 MHz RF communication module, 

 

MOD-ZWAVE - communication module with Smart Home devices. 

Содержание AVA PRO CPX300W

Страница 1: ...EN AVA PRO Control panel CPX300W Firmware version 3 1 7 Instructions version v1 3 Release date 26 05 2020 Assembly instructions for the AVA PRO CPX300W alarm control panel...

Страница 2: ...y kind either expressed or implied are provided including but not limited to any implied warranties of merchantability or suitability for a certain purpose unless such a required by law The manufactur...

Страница 3: ...module 12 3 4 WiFi 12 3 4 1 Description 12 3 4 2 Module installation 12 3 4 3 Technical parameters 13 3 5 RF433 13 3 5 1 Description 13 3 5 2 Module installation 13 3 5 3 Technical parameters 14 3 5...

Страница 4: ...nel along with a discussion of the parameters and operating principles The information contained herein will allow a quick and trouble free installation NOTE All information regarding the AVA PRO syst...

Страница 5: ...ic contact with an additional input PIR 30 motion detector PIRC AM 30 motion detector with a camera RC 30 remote control STAG 30 touchless user identifier AVA KEY BM8000PLx C3W visual audible wireless...

Страница 6: ...a GPRS SMS Ethernet Wi Fi 11 Programmers MINI PROG BT a programmer that allows configuration and monitoring of the control panel thanks to the IDC10 connector and Bluetooth technology GD PROG a progra...

Страница 7: ...required min 20 VA Current consumption 18VAC average max 85 mA 130 mA 18VAC in 2G mode with MOD GSM 2G modem uBlox Sara G350 78 mA 130 mA 18VAC in 3G mode with MOD GSM 3G modem uBlox Sara U201 Current...

Страница 8: ...onnected battery but without the mains power supply MODE user base formatting button including installer code To run the process press the button turn on the power supply of control panel holding for...

Страница 9: ...built in 868 MHz module Place for a latch securing the antenna wire included to the module together with the set P1 P2 P3 P4 Yellow LEDs indicating the signal level for the GSM module Steady light rep...

Страница 10: ...on the CPX300W motherboard labelled cellular network see Figure 1 item 6 and then screwed with a screw attached to the set The module has two sockets for mounting nano SIM cards To place the card sli...

Страница 11: ...icantly reduce its range 3 2 5 Technical parameters of the GSM module Table 2 Technical parameters of the GSM module Module variant 2G 3G Modem SARA G350 SARA U201 Supported frequency bands 2G 850 MHz...

Страница 12: ...Ethernet module Table 3 Technical parameters of the Ethernet module Supported connection standards 10Base T 100Base TX Auto MDI MDI X Ethernet connector RJ45 shielded Dimensions 36 5 mm x 27 mm 3 4 W...

Страница 13: ...266EX 3 5 RF433 3 5 1 Description A radio communication module cooperating with the CPX300W alarm control panel powered directly from the control panel motherboard This module enables to add one way d...

Страница 14: ...5 mm 3 5 4 433 MHz antenna The set includes two types of antennas Internal wire antenna An internal antenna can be used wherever compactness is required and it provides the appropriate level of detec...

Страница 15: ...alarm control panel with the elements of Smart Home Connector for installation of the module u FL antenna connection Mounting hole for the screw Fig 8 View of MOD Z Wave module boards with description...

Страница 16: ...Logged in correctly to the GSM network lights steadily flashes Table 8 Ethernet Wi Fi network login indication LED indicator Description STATUS green ETH WiFi yellow Ethernet Wi Fi network login attem...

Страница 17: ...l which results in switching off all 15 LEDs for about 1 second and then lighting all LEDs also for about 1 second 3 7 4 No SIM card or damage to the SIM card After detection of the main SIM card in t...

Страница 18: ...this signal is correct you can proceed to the proper permanent installation of the system 4 Perform the remaining cable connections 5 Connect the battery to the screw terminals BAT BAT and then the e...

Страница 19: ...icks Loss 5 35 Reinforced concrete or metal substrate Loss 30 90 Fig 11 Loss of radio signal strength after passing through various materials 4 3 Location of wireless detectors When installing devices...

Страница 20: ...an alarm DEOL NO a line type for connecting detectors with a normally open alarm output NO and a tamper output The input distinguishes three states normal alarm and sabotage DEOL NC a line type for co...

Страница 21: ...AVA PRO Assembly instructions for the CPX300W alarm control panel 21 23 Fig 12 Configuration of the input line Detector No 1 Detector No 2...

Страница 22: ...l panel 22 23 4 5 An example of connecting the siren without battery Fig 13 An example of connecting an internal siren without battery 4 6 An example of connecting the siren with own battery Fig 14 An...

Страница 23: ...vision Firmware Description 2019 07 12 w1 0 3 0 2 First version of the manual 2019 12 06 w1 1 3 1 0 Description of the MODE button technical specification updated 2020 02 27 w1 2 3 1 5 Technical speci...

Отзывы: