W4S250-DI02-01
3.2
Nominal data
Motor
M4S068-CF
Phase
1~
1~
Nominal Voltage / VAC
230
230
Frequency / Hz
50
60
Type of data definition
Running at free air
Valid for approval /
standard
CE
CE
Speed / rpm
1390
1600
Power input / W
69
63
Current draw / A
0.53
0.45
Max. Back pressure / Pa
80
80
Min. ambient temperature /
°C
-25
-25
Max. ambient temperature /
°C
50
65
Starting current / A
0.85
0.7
Max. safe operating speed /
rpm
2950
@ 85 ºC
2950
@ 85 ºC
Subject to alterations
3.3
Technical features
Mass
3.64 kg
Size
250 mm
Surface of rotor
Coated in black
Material of blades
Sheet steel, coated in black
Number of blades
9
Material of guard grille
Steel phosphate and coated in
black
Material of wall ring
Sheet steel, pre-galvanised
and coated in black plastic
Direction of airflow
“A”
Direction of rotation
Counter clockwise, seen on
rotor
Type of protection
IP 44
Moisture (F) /
Environmental (H)
protection class
H0+
Humidity class
F1-2
Mounting position
Shaft horizontal or rotor on
bottom; rotor on top on request
Condensate discharge
holes
Rotor-side
Operation mode
S1
Motor bearing
Ball bearing
Touch current acc. IEC
60990 (measuring
network Fig. 4, TN
system)
< 0.75 mA
Motor protection
Thermal overload protector
(TOP) wired internally
Cable exit
Lateral
Protection class
I (if protective earth is
connected by customer)
Product conforming to
standard
CE
Approval
EAC
For cyclic speed loads, note that the rotating parts of
the device are designed for maximum one million
load cycles. If you have specific questions, contact
ebm-papst A&NZ for support.
3.4
Mounting data
Secure the mounting screws against accidentally coming
loose (e.g. by using self-locking screws).
You can obtain additional mounting data from the product
drawing if necessary.
3.5
Transport and storage conditions
Use the device in accordance with its protection type.
Max. permissible ambient motor
temp. (transp./storage)
+ 80 °C
Min. permissible ambient motor
temp. (transp./storage)
- 40 °C