W3G500GN3307-LA1 

4.6

 

Checking connections 

 

Ensure isolation from supply (all phases). 

 

Make sure a restart is impossible 

 

Check the cables for proper fit. 

 

Screw the terminal box cover closed again. Terminal box 
tightening torque, see chapter 3.1 Product drawing. 

 

Route the cables in the terminal box so that the terminal box 
cover closes without resistance. 

 

Use all plug screws. Insert the screws by hand to avoid 
damage to the thread. 

 

Make sure that the terminal box is completely closed and 
that all screws and cable glands are properly tightened. 

4.7

 

Switch on the device 

The device may only be switched on if it has been installed 
properly and in accordance with its intended use, including the 
required safety mechanisms and professional electrical 
connection. This also applies for devices that have already been 
equipped with plugs and terminals or similar connections by the 
customer. 
 

WARNING 
Hot motor housing 

Risk of fire hazard 

→  Ensure that no combustible or flammable 

materials are located close to the fan. 

 

Before switching on, check the device for visible external 
damage and make sure the devices are functional. 

 

Check the air flow paths of the fan for foreign objects and 
remove any that are found. 

 

Apply the nominal supply voltage. 

 

Start the device by changing the input signal. 

4.8

 

Switching off the device 

Switching off the device during operation: 

 

Switch on the device via the control input. 

 

Do not switch the motor (e.g. in cyclic operation) on and off 
via power supply. 

 
Switching off the device for maintenance work: 

 

Switch on the device via the control input.  

 

Do not switch the motor (e.g. in cyclic operation) on and off 
via power supply. 

 

Disconnect the device from the power supply. 

 

When disconnecting, be sure to disconnect the earth wire 
connection last. 

5.

 

INTEGRATED PROTECTIVE FUNCTIONS 

The integrated protective functions cause the motor to switch off 
automatically in the event of the faults described in the table. 
The status relay drops out and the fault is reported via BUS. 

Fault 

Safety feature description / function  

Rotor position 
detection error 

An automatic restart follows. 

Blocked rotor 

After the blockage is removed, the 

motor restarts automatically. 

Line-under voltage 
(line voltage outside of 
permitted nominal 
voltage range) 

If the line voltage returns to 

permitted values, the motor restarts 
automatically. 

Phase failure 

A phase of the supply voltage fails for 
at least 5 s. 

When all phases are correctly 

supplied again, the motor automatically 
restarts after 10-40 s. 

Содержание W3G500GN3307-LA1

Страница 1: ...disposal 12 1 SAFETY REGULATIONS AND INFORMATION Read these operating instructions carefully before starting work on the device Observe the following warnings to prevent malfunctions or danger to pers...

Страница 2: ...device immediately if you notice a missing or ineffective protective feature 1 6 Electromagnetic radiation Interference from electromagnetic radiation is possible e g in conjunction with open and clos...

Страница 3: ...resses that can occur Intended use also includes Use the device in power systems with earthed neutral TN TT power systems only Using the device only in stationary systems Performing all maintenance wo...

Страница 4: ...6400 NSW Fax 61 02 9827 6464 NZ Phone 64 09 525 0245 NZ Fax 64 09 525 0246 sales ebmpapst com au www ebmpapst com au W3G500GN3307 LA1 3 TECHNICAL DATA 3 1 Product drawing AIRFLOW DIRECTION All dimensi...

Страница 5: ...from the mains Over temperature protected electronics motor Line under voltage phase failure detection Touch current acc IEC 60990 measuring network Fig 4 TN system 3 5 mA Electrical leads Via termina...

Страница 6: ...is a built in component and has no electrically isolating switch Only connect the fan to circuits that can be switched off with an all pole separating switch When working on the fan you must switch o...

Страница 7: ...D protective devices cannot provide personal safety while operating the device When switching on the power supply of the device pulsed charge currents from the capacitors in the integrated EMC filter...

Страница 8: ...s not included in the scope of delivery into the terminal box First connect the PE protective earth Connect the lines to the corresponding terminals Use a screwdriver to do so When connecting ensure...

Страница 9: ...A max 250 VAC min 10 mA AC1 KL2 3 NO Floating status contact make for failure KL3 1 OUT Analogue output 0 10 VDC max 3 mA SELV Output of the current motor level 1 V corresponds to 10 level 10 V corres...

Страница 10: ...flammable materials are located close to the fan Before switching on check the device for visible external damage and make sure the devices are functional Check the air flow paths of the fan for forei...

Страница 11: ...cleaning Motor not turning Mechanical blockage Switch off isolate from supply and remove mechanical blockage Voltage faulty Check mains supply voltage restore power supply Important The error message...

Страница 12: ...from the development stage ecological design technical safety and health protection are fixed criteria The following section contains recommendations for ecological disposal of the product and its com...