31)
EBARA
Corporation
6.3.1 Setting the pump operation control mode
A case of display if Local mode selected.
REMOTE MODE : Enables the remote operation
(start/stop with external signals)
LOCAL MODE : Enables the local operation
(start/stop with the LCD controller)
COM MODE : Enables the communication operation
(start/stop with RS232C communication)
The mode that is currently not set is displayed.
If you do not need to set, press PRG. key to go back to the previous screen.
SET
CONTROL MODE
?
PRG.
PRG.
ENTER
ENTER
ENTER
COM MODE?
REMOTE MODE?
Setting done
Setting done