background image

Acoustical Performance Partnership

Eastern Acoustic Works

Group E Summary Specifications

One Main Street, Whitinsville, MA 01588 • (508) 234 - 6158 • FAX (508) 234 - 8251 • Email [email protected] • Web http://www.eaw.com

Acoustical Performance Partnership

Eastern Acoustic Works

Group E Summary Specifications

One Main Street, Whitinsville, MA 01588 • (508) 234 - 6158 • FAX (508) 234 - 8251 • Email [email protected] • Web http://www.eaw.com

AUDIO PERFORMANCE

Dynamic Range

115 dB typical
(

108 dBu)

THD+N

(0 dBu 20-Hz 20 kHz)
0.03% typical (

0.08%)

INPUT

Connectors

Female XLR (Locking)

Type

Electronically Balanced
Differential

Differential

Input >10 k

Common-Mode
Input

30 k

Input Overload

(20 Hz - 20 kHz)
+18 dBu

OUTPUT

Connectors

Male XLR

Type

Single-Ended

Impedance

10 

Max Voltage

+18 dBu

Minimum
Resistive Load

300 

Maximum
Capacitive Load

22 nF (Outputs are
stable with any
capacitive load.)

Offset Voltage

±

1.5 mV

(

±

10 mV limit)

Output Noise (20 Hz - 20 kHz,
RS=600 

)

MX200i HF
MX300i HF
MX800i HF

-97 dBu Typical
(

 94 dBu)

MX200i LF
MX300i LF/SB
MX800i MF/LF/SB

-100 dBu Typical
(

 97 dBu)

ELECTRICAL/
ENVIRONMENTAL

Dimensions

19" W x 3.5" H x 10" D

Line Input Power

30 W

Line Voltage Requirements

115 VAC Setting

90 -135 VAC, 50-60 Hz

230 VAC Setting

195 - 270 VAC, 50-60 Hz

Line Input/
Fuse Holder

IEC 320 socket with
5 x 20 mm fuseholder

Operating
Temperature

0

°

 - 50

°

 Celsius

Accessories
Included

UL/CSA Line Cord,
Spare Line Fuse (in
Fuse Holder)

MX200i, MX300i, MX800i
HF SECTION DATA

HF Equalization

Shelving EQ Circuit,
Boost Set Via Internal
Multiposition Jumper,
MX300i/MX800i Switch
Defeats Circuit

Highpass
Filter Type

Two Cascaded
Second-Order
Sections, Variable F

0

Set Via Internal
Resistor SIP

Lowpass Filter Type Third-Order

Butterworth

Limiter Type

RMS Above Threshold
Infinite Compressor

Limiter Time
Constant

39 msec

Limiter Threshold

Set via Internal Master
Threshold Control & HF
Threshold Resistor

Pass Band Gain

Range of 

±

 10 dB Set

via Internal HF Gain
Resistors

MX800i MF SECTION DATA

Highpass
Filter Type

Two Cascaded
Second-Order
Sections, Variable F

0

Set via Internal
Resistor SIP

Lowpass Filter Type Two Cascaded Second-

Order Sections,
Variable F

º

 Set via

Internal Resistor SIP

Phase

Network Type,
MF/HF 1st Order Allpass

Phase Adjustment

0

°

 - 180

°

 (F

º

 Set via

Internal MF Phase
Resistor)

Limiter Type

RMS Above Threshold
Infinite Compressor

Limiter
Time Constant

85 msec

Limter Threshold

Set via Internal Master
Threshold Control & MF
Threshold Resistor

Pass Band Gain

Range of 

±

 10 dB Set

via Internal MF Gain
Resistors

MX200i LF SECTION DATA

Lowpass Filter Type Two Cascaded Second-

Order Sections,
Variable F

º

 Set via

Internal Resistor SIP

Phase
Network Type

1st Order Allpass

Phase Adjustment,
LF/HF

0

°

 - 180

°

 (F

º

 Set via

Internal LF Phase
Resistor)

Limiter Type

RMS Above Threshold
Infinite Compressor

Limiter
Time Constant

182 msec

Limter Threshold

Set via Internal Master
Threshold Control & LF
Threshold Resistor

Pass Band Gain

Range of 

±

 10 dB Set

via Internal LF Gain
Resistors

LF Equalization

Underdamped 2nd
Order Sallen-Key
Highpass Filter,
Variable F

º

 & Q Set via

Internal PCB’s

Dynamic LF
Excursion Control

Sliding 2nd Order
Highpass Filter
Controlled by RMS
Level in LF Passband,
Engages when RMS
Level is within 10 dB
of LF RMS Threshold

Fixed LF
Excursion Control

2nd Order
Butterworth Highpass
Filter, Variable F

º

 Set

via Internal PCB’s

MX300i, MX800i LF
SECTION DATA

All Sub Modes

Lowpass Filter Type Two Cascaded Second-

Order Sections,
Variable F

º

 Set via

Internal Resistor SIP

Phase Network
Type

1st Order Allpass

Phase Adjustment,
LF/MF

0

°

 - 180

°

 (F

º

 Set via

Internal LF Phase
Resistor)

Limiter Type

RMS Above Threshold
Infinite Compressor

Limiter Time
Constant

85 msec

Limter Threshold

Set via Internal Master
Threshold Control & LF
Threshold Resistor

Pass Band Gain

Range of 

±

 10 dB Set

Via Internal LF Gain
Resistors

SUB ADJ Mode

Highpass
Filter Type

Two Cascaded
Second-Order
Sections, Variable F

º

Set via Internal
Resistor SIP

SUB DIST Mode

Fixed LF

Excursion Control

2nd Order
Butterworth Highpass
Filter, Variable F

º

 Set

Via Internal PCB’s

Dynamic LF
Excursion Control

Sliding 2nd Order
Highpass Filter
Controlled by RMS
Level in SUB
Passband, Engages
when RMS Level is
within 10 dB of SUB
RMS Threshold

SUB OFF Mode

Fixed LF
Excursion Control

Two Cascaded 2nd
Order Highpass
Filters, Variable F

º

 Set

via Internal PCB’s

Dynamic
LF Equalization

Underdamped Sliding
2nd Order Highpass
Filter Controlled by
RMS Level in SUB
Passband, Engages
when RMS Level is
within 10 dB of SUB
RMS Threshold

MX300i, MX800i, SUB
SECTION DATA

SUB Mono

Front Panel Button
Sums Both SUB Bands,
Each Attenuated 3 dB

SUB Boost

Front Panel Button
Increased Passband
Gain 6 dB

Polarity

Front Panel Switch
Reverses Polarity When
Depressed

Lowpass
Filter Type

Two Cascaded
Second-Order
Sections, Variable F

º

Set via Internal
Resistor SIP

Phase
Network Type

1st Order Allpass

Phase Adjustment,
LF/SUB

0

°

 - 180

°

 (F

º

 Set via

Internal SUB Phase
Resistor)

Limiter Type

RMS Above Threshold
Infinite Compressor

Limiter
Time Constant

182 msec

Limter Threshold

Set via Internal Master
Threshold Control &
SUB Threshold Resistor

Pass Band Gain

Range of 

±

 10 dB Set

via Internal LF Gain
Resistors

Dynamic SUB
Excursion Control

Sliding 2nd Order
Highpass Filter
Controlled by RMS
Level in SUB
Passband, Engages
when RMS Level is
within 10 dB of SUB
RMS Threshold

SUB Equalization

Underdamped 2nd
Order Sallen-Key
Highpass Filter,
Variable F

º

 & Q Set

via Internal PCB’s

MX100 Technical Specifications

ELECTRICAL/
ENVIRONMENTAL

Dimensions             19” W x 1.75”
                               H x 6.25” D
Line Input Power

5 Watts

Line Voltage Requirements

120 VAC Setting

103-127 VAC, 50-60 Hz

 240 VAC Setting

206-255 VAC, 50-60 Hz

Line Input

!EC 320 Block

Fuse Holder

Tamper-proof Screw
Release

Fuse Type

T1A

Operating
Temperature

0º - 50

°

 Celsius

Accessories
Included

UL/CSA Line Cord

CROSSOVER FILTER TYPE

HF High Pass

4

th

 Order Linkwitz-

Riley, Variable F

0

LF Low Pass

4

th

 Order Linkwitz-

Riley, Variable F

0

CROSSOVER CUTOFF
FREQUENCIES

HF High Pass

60 Hz - 2 kHz

LF Low Pass

60 Hz - 2 kHz

SYSTEM HIGHPASS
AND  LOWPASS

LF High Pass

4

th

 Order, Variable Q,

Variable F

0

HF Low Pass

4

TH

 Order

Butterworth, -3 dB @
35.2 kHz

 PASS BAND GAIN

HF/LF

-10 dB to +10 dB

MX200i, MX300i, MX800i Technical Specifications

AUDIO PERFORMANCE

Dynamic Range

Nominal 115 dB,
> 105 dB

THD+N (0 dBu
20 Hz – 20 kHz)

.003% (

.005%)

INPUT

Connectors

Female XLR (Locking)

Type

Electronically Balanced
Differential

Differential

15 k

 Input

Impedance

Unbalanced

7.5 k

 Input

Impedance

Input Overload

(20 Hz – 20 kHz)

20 dBU

OUTPUT

Connectors

Male XLR (Locking)

Type

Single-Ended

Impedance

47 

Max Voltage

20 dBU

Minimum
Resistive Load

1 k

Maximum
Capacitive Load

10 nF (Outputs are
stable with any
capacitive load.)

Output Noise

(20 Hz – 20 kHz, R

s

 =

600 

, All Bands Unity

Gain)

LF/HF

100 dB (typical)

OPERATING MODES

(Note: Mode is set internally)

Stereo Low Mode

HF Outputs

2 Male XLR’s

LF Outputs

3 Male XLR’s
(1 Left Channel,
 2 Right Channel)

Mono Low Mode

HF Outputs

2 Male XLR’s

Summed Mono LF

2 Male XLR’s

Summed Mono
Full Range

1 Male XLR

Отзывы: