![Eaton XV-112 Скачать руководство пользователя страница 26](http://html1.mh-extra.com/html/eaton/xv-112/xv-112_operating-instructions-manual_3796266026.webp)
5 Installation
5.3 Interfaces
26
MICRO PANEL XV-112
11/2011 MN04802005Z-EN
www.eaton.com
5.3.4
RS232 (System Port)
The RS232 interface is
not
electrically isolated. The GND pin is directly connected to the housing
potential.
Tab. 7 Pin assignment of the RS232 interface
Wiring
Shielded cables must be used.
The maximum baud rate depends on the cable length:
Tab. 8 Relationship of cable length / baud rate
CAUTION
Non-isolated interfaces
The device may be damaged due to potential differences.
The GND terminals of all bus stations must be connected.
Fig. 9 RS232 interface (9-pin, D-Sub, male, UNC)
Pin
Signal
Assignment
1
DCD
Data Carrier Detected
2
RxD
Receive Data
3
TxD
Transmit Data
4
DTR
Data Terminal Ready
5
GND
Ground
6
DSR
Data Set Ready
7
RTS
Request to Send
8
CTS
Clear to Send
9
RI
Ring Indicator
1 2 3 4 5
6 7 8 9
Cable length
Max. baud rate
2.5 m
115200 Bit/s
5 m
57600 Bit/s
10 m
38400 Bit/s
15 m
19200 Bit/s
30 m
9600 Bit/s
Содержание XV-112
Страница 1: ...Operating Instructions 11 2011 MN04802005Z EN XV 112 MICRO PANEL...
Страница 6: ...1 General 1 3 Additional documentation 6 MICRO PANEL XV 112 11 2011 MN04802005Z EN www eaton com...
Страница 16: ...3 Safety regulations 3 4 Device related hazards 16 MICRO PANEL XV 112 11 2011 MN04802005Z EN www eaton com...
Страница 18: ...4 Operating and indication elements 4 1 Overview 18 MICRO PANEL XV 112 11 2011 MN04802005Z EN www eaton com...
Страница 38: ...5 Installation 5 4 Mounting 38 MICRO PANEL XV 112 11 2011 MN04802005Z EN www eaton com...
Страница 42: ...6 Operation 6 4 Inserting and removing an SD card 42 MICRO PANEL XV 112 11 2011 MN04802005Z EN www eaton com...
Страница 56: ...9 Technical data 9 9 Ambient conditions 56 MICRO PANEL XV 112 11 2011 MN04802005Z EN www eaton com...