EATON xChargeIn UDP Programmers Guide V 2.01
EATON xChargeIn, UDP Programmers Guide V 2.01
26
© EATON 2018
3.2.12
UDP command: display
Command structure
Command
Parameters
Additional Description
display
[a] [min]
[max]
[tk] [text]
[a]
Determines whether default or non-default
values are used for the duration [text] is
displayed. 0 = default (min duration = 2 sec,
max duration = 10 sec, fixed token); 1 = min
and max duration can be defined.
[min]
Defines the duration in seconds how long the
text is displayed before another display
command will be processed (internal MID
metering relevant information may overrule
this).
[max]
Defines the duration in seconds how long the
text is displayed if no additional display
command follows.
[tk]
Token
– for internal use only.
[text]
Text shown on the display. A maximum of 23
ASCII characters can be used.
Note: $ will be replaced by a blank space. ~
will be replaced by a Σ
Reply structure
Field
Contents
Additional Description
-
TCH-OK: done
Generic confirmation message
Example
3.2.13
UDP command: unlock
The command
unlock
unlocks the socket of the device. The charging
process has to be stopped first (e.g. via
currtime 0 1
or
ena 0
)
Command structure
Command
Parameters
Additional Description
unlock
-
-