7 Malfunctions
Compact PLC XC-152
05/17 MN050001ZU EN www.eaton.com
65
7 Malfunctions
Error conditions
SD card not found
(COM flashing orange)
Solution:
▶
Insert SD card
▶
Press the
CTRL button
.
The device will boot up with the
internal operating system.
Operating system obsolete or not found
(COM flashing red)
Solution:
▶
Copy a new operating system
onto the SD card
▶
Press the
CTRL button
.
The device will boot up with the
internal operating system.
Boot error
Occurs if:
An invalid operating system is stored in InternalStorage
and this invalid internal operating system is loaded due to
the CTRL button being pressed.
Hardware fault
Make sure that the jumper on the UPD/RUN pin header is
not set to UPD.
Servicing required: Please contact your supplier.