TWIN LED Technical Manual

TWIN LED TECHNICAL MANUAL

  TMF001   July 2019   www.eaton.com

Acoustic signalling

Sound transducer

Rocking Armature Transducer

Acoustic signal

8 different settings (can be selected using sliding switch)

Volume setting

4 loud melodies selectable

4 quieter melodies selectable

Maximum volume

approx. 101 dB(A) at a distance of 1m

Minimum volume

approx. 91 dB(A) at a distance of 1m

Optical signalling

Optical signal indicator

3 x LEDs

Colour choice

Coloured spherical cap

Flash duration

80 ms

Flash frequency

1 Hz

Signalling after end of call

(call break bypass) approx. 4s

Housing

Material

Aluminium die casting with powder-coated surface Spherical cap made of UV-resistant 

polycarbonate in the colours white, blue, green, red or orange

Weight

approx. 1.7 kg

Normal operating position

any

Environmental conditions

Operating ambient temperature

-40°C … +65°C 

in accordance with IEC60721

Transport and storage temperature

-40°C … +85°C 

in accordance with IEC 60529

Protection class

IP66

Safety class

I (PE connection available)

Connection plan

Telephone network

Connect in parallel to the telephone, independently of polarity (TCP1, TCP2).

Power supply network

With direct current networks, the polarity is to be considered.

With alternating current networks, the outer conductor is to be connected to L, the neutral 

conductor to N and the protective earth conductor to PE.

Potential equalisation

Is to be connected for all executions – including DC supply. The connection on the outside of 

the housing.

Содержание TWIN LED

Страница 1: ...TWIN LEDTechnical Manual Telefon Zweit und Signalmelder Secondary telephone call and signal indicator TWIN LED...

Страница 2: ...te erfolgt ber den Elektronikabfall Bei Demontage des Ger tes sind die Komponenten Kunststoff Metalle und Elektronik separat zu entsorgen Note Before installing the device these instructions are to be...

Страница 3: ...ened The connection and setting of the device may only be carried out by instructed specialist personnel The regu lations and instructions of the respective country for connecting to the public teleph...

Страница 4: ...schlussdaten Kabel und Leitungseinf hrungen 2 St ck M20 x 1 5 Klemmverm gen 0 2 2 5 mm Litze 0 2 4 mm massiv Netzanschluss Klemmenbezeichnung Bei AC Versorgung L N PE zus tzlich PA au en Bei DC Versor...

Страница 5: ...he Signalisierung Optischer Signalmelder 3 x LEDs Farbwahl farbige Kalotte Blitzdauer 80 ms Blitzfrequenz 1 Hz Signalisierung nach Rufende Rufpausen berbr ckung ca 4s Geh use Material Aluminiumdruckgu...

Страница 6: ...sion 253 VAC Nominal data at 230 VAC INS 0 02 A No Signal Current IN 0 042 A Nominal Active Current IICL 0 4 APeak Inrush Current Limit PN 5 W Nominal Active Power SN 8 VA Nominal Apparent Power 0 62...

Страница 7: ...surface Spherical cap made of UV resistant polycarbonate in the colours white blue green red or orange Weight approx 1 7 kg Normal operating position any Environmental conditions Operating ambient te...

Страница 8: ...ei der Montage und Demontage nicht besch digt werden 11 Bei Instandsetzung des Betriebsmittels zum Einsatz in Staub sollten die instandgesetzten Teile einer erneuten St ckpr fung unterzogen werden 12...

Отзывы: