Sonix Ms12 Technical Manual

SONIX MS12 TECHNICAL MANUAL  

TM371 / A  June 2022  www.eaton.com

5 .4  Message Initiate 

Two off 12-way connectors provide the interface to 

remotely trigger any of the 12 messages. Each input 

requires a “volt free” contact to activate the input.

Cable Specification

Type

Description

Label

1 off pair per initiate

Output

Keyline 1

NC

Output

Keyline 2

COM

Table 6 - Message monitoring interface description

ote: 

N

Care should be taken if multiple inputs are driven from non-

isolated sources as inputs share a common 0V connection and cross-

overs could cause permanent activation.

Typical wiring connections

Figure 4 - Message Initiate connections

Maximum cable section supported are:

• 

Solid:   

1.5 mm

2

• 

Stranded:  

0.5 mm

2

 including sleeved ferrule

• 

Stranded:  

1.5 mm

2

 including non-sleeved ferrule

5 .5  Power connections

Power to the Sonix Ms12 should be provided via a 

2-core 48 V dc input on the rear of the unit. This input 

should be connected to the managed and regulated 

48 V dc power output from the Sonix PM10 power 

management unit.

ote: 

N

As these cables are power feeds they should be routed within 

the PA/GA system in a way to avoid contact with signal or audio cables 

and other high voltage cables.

Cable Specification

Type

Description

Label

1off pair

Input

+48 V dc

+

Input

0 V dc

-

Table 7 - Power interface description

Typical wiring connections (A-side & B-side)

Figure 5 - Power connections

Maximum cable section supported are:

• 

Solid:   

1.5 mm

2

• 

Stranded:  

0.5 mm

2

 including sleeved ferrule

• 

Stranded:  

1.5 mm

2

 including non-sleeved ferrule

5 .6  General fault output connections

The general fault output is a volt free contact output. 

The output can be set in configuration to either normally 

open or normally closed. The output will be open when 

the unit is de-powered, no matter what configuration  

is selected.

Warning: 

Do not exceed maximum allowed 

voltages on fault output, see datasheet for more 

details.

ote: 

N

It is recommended that the fault output be configured as nor-

mally closed.

R

Power

Reset

Source Select

Zoned / Global

Cancel

USB

Line In

Fuse

DC PSU

Message

1

Message

2

Message

3

Message

4

Message

5

Message

6

Message

7

Message

8

Message

9

Message

10

Message

11

Message

12

Message

Check

Sonix   Pbx

TM

POWER SUPPLY

OPERATIONAL 

7

6

5

4

3

2

1

I/O Bus A

I/O Bus B

A1

A2

SCN

K1

K2

A SIDE O/P

48V

DC

I/P

+    -

Fault 

O/P 

N/C 

Com

COM

N/C

COM

N/C

COM

N/C

COM

N/C

COM

N/C

COM

N/C

COM

N/C

COM

N/C

COM

N/C

COM

N/C

COM

N/C

COM

N/C

12

11

10

9

8

7

6

5

4

3

2

1

MESSAGE INITIATE

A1

A2

SCN

K1

K2

B SIDE O/P

USB

LOAD

LINE IN

COMPLIANT

9

8

7

6

5

4

3

2

1

Keyline connection

Screen

Audio connection

Power connection

0Vdc (-)

48Vdc (+)

General fault connection

N/C

Com

Message Initiate 6

Message Initiate 1

Message Initiate 12

Message Initiate 7

1 k

W

Ms12 Connection

Audio source connection

e.g. mobile phone, computer

R

Power

Reset

Source Select

Zoned / Global

Cancel

USB

Line In

Fuse

DC PSU

Message

1

Message

2

Message

3

Message

4

Message

5

Message

6

Message

7

Message

8

Message

9

Message

10

Message

11

Message

12

Message

Check

Sonix   Pbx

TM

POWER SUPPLY

OPERATIONAL 

7

6

5

4

3

2

1

I/O Bus A

I/O Bus B

A1

A2

SCN

K1

K2

A SIDE O/P

48V

DC

I/P

+    -

Fault 

O/P 

N/C 

Com

COM

N/C

COM

N/C

COM

N/C

COM

N/C

COM

N/C

COM

N/C

COM

N/C

COM

N/C

COM

N/C

COM

N/C

COM

N/C

COM

N/C

12

11

10

9

8

7

6

5

4

3

2

1

MESSAGE INITIATE

A1

A2

SCN

K1

K2

B SIDE O/P

USB

LOAD

LINE IN

COMPLIANT

9

8

7

6

5

4

3

2

1

Keyline connection

Screen

Audio connection

Power connection

0Vdc (-)

48Vdc (+)

General fault connection

N/C

Com

Message Initiate 6

Message Initiate 1

Message Initiate 12

Message Initiate 7

1 k

W

Ms12 Connection

Audio source connection

e.g. mobile phone, computer

Содержание SONIX Ms12

Страница 1: ...SONIXTM Ms12 Message Store Unit SonixTM Ms12 Technical Manual...

Страница 2: ...FOR A PARTICULAR PURPOSE OR MERCHANTABILITY OTHER THAN THOSE SPECIFICALLY SET OUT IN ANY EXISTING CONTRACT BETWEEN THE PARTIES ANY SUCH CONTRACT STATES THE ENTIRE OBLIGATION OF EATON THE CONTENTS OF...

Страница 3: ...feedback 2Mx Sonix 2Mx Central controller Amp 350 d Sonix 350 W Power Amplifier with 100 V line output Eol1 Sonix Remote End of Line unit Eol8 Sonix Amplifier to 100 V line interface unit 8 channel S...

Страница 4: ...key line outputs 11 5 3 Line In 11 5 4 Message Initiate 12 5 5 Power connections 12 5 6 General fault output connections 12 6 UNIT OPERATION 13 6 1 Data and audio communications 13 6 1 1 PA GA mounted...

Страница 5: ...ity 23 8 CUSTOMISATION 23 9 MAINTENANCE 23 List of Figures FIGURE 1 FRONT PANEL LAYOUT 10 FIGURE 2 REAR PANEL LAYOUT 10 FIGURE 3 ISOLATED AUDIO AND KEYLINE OUTPUTS 11 FIGURE 4 MESSAGE INITIATE CONNECT...

Страница 6: ...MESSAGE STATUS INDICATOR DESCRIPTION 14 TABLE 10 PLAYBACK MESSAGE GREEN STATUS INDICATOR DESCRIPTION 14 TABLE 11 PLAYBACK MESSAGE RED STATUS INDICATOR DESCRIPTION 14 TABLE 12 FRONT PANEL PLAYBACK GREE...

Страница 7: ...7 Sonix Ms12 Technical Manual SONIX MS12 TECHNICAL MANUAL TM371 A June 2022 www eaton com...

Страница 8: ...e goods during transit Please ensure that once unpacked checked and installed that all packaging is disposed recycled in a responsible manner 2 3 ESD Electro Static Discharge The Sonix PA GA system is...

Страница 9: ...to the needs of system installation The unit allows for duplicated connections to A side and B side systems while allowing synchronised audio to be broadcast over both systems The unit occupies a stan...

Страница 10: ...OWERSUPPLY OPERATIONAL 7 6 5 4 3 2 1 I O Bus A I O Bus B A1 A2 SCN K1 K2 A SIDE O P 48V DC I P Fault O P N C Com COM N C COM N C COM N C COM N C COM N C COM N C COM N C COM N C COM N C COM N C COM N C...

Страница 11: ...e system for redundancy Bus Name Colour Connected to Data type IO Bus Blue Io Ms12 PBx units Transmit Unit control status data Active system Audio Receives System control and status data Table 3 IO Bu...

Страница 12: ...side Figure 5 Power connections Maximum cable section supported are Solid 1 5 mm2 Stranded 0 5 mm2 including sleeved ferrule Stranded 1 5 mm2 including non sleeved ferrule 5 6 General fault output co...

Страница 13: ...of either one of a pair of RJ45 cable becoming disconnected the data audio has a redundant path ensuring the Ms12 will continue to operate without any loss of functionality A flashing IO fault is log...

Страница 14: ...n be accessed to check message content using the front panel Table 13 Playback message red status indicator description 6 2 2 4 Front panel record These indications are only displayed by the unit whil...

Страница 15: ...Local Reset Solid green Allows the user to carry out a fault reset on the unit Table 19 Switch indicator description 6 3 Front panel operation From the front of the Ms12 a selection button on the rig...

Страница 16: ...ont panel button allow the selected message to be cycled The selected message will play once before returning to quiescent Playback Message Select no message Timeout Button Pressed Message Select Time...

Страница 17: ...s For more detailed information and instructions please see section 6 4 6 3 3 1 Message slot selection To a record a new message the user needs to identify the message slot to use This is achieved usi...

Страница 18: ...in order to achieve the best clarity The output level and clarity of the original recording will significantly affect the unit s recording of the message Message slots 1 11 allows up to 60 seconds of...

Страница 19: ...while the input is active De activating an input after the message has started will cause it to play to the end before stopping ote N Initiating and holding active a rear panel initiate will cause the...

Страница 20: ...nitiation 6 7 Message Playback Once a message has been initiated for playback the unit enters the playback process This process differs depending on whether the unit is connected with CAT6A cables as...

Страница 21: ...sage slot can be individually configured to auto elevate to Emergency Speech If a message is elevated to Emergency Speech broadcast its priority is raised above any active Alarms on the PA GA system a...

Страница 22: ...ated from each other J9 and J10 on the PCB are two jumper links to connect the shield from each CAT6A connector to either Earth or to the respective 0V rail ote N J9 and J10 should be left connected t...

Страница 23: ...ve if the custom special functionality or operation of the Sonix system and or Ms12 is required 9 Maintenance The Sonix Ms12 unit itself does not require any specific maintenance but the following gen...

Страница 24: ...aton and SONIX are registered trademarks All other trademarks are property of their respective owners Changes to the products to the information contained in this document and to prices are reserved s...

Отзывы: