background image

Page 5 

Fault and Tamper Monitoring 

The siren continuously monitors for fault 
and tamper conditions and reports any 
found to the control unit/expander via the 
radio link. The following are monitored: 

 

Tamper switch

 

– The siren's tamper 

switch is continuously monitored. The 
siren self-activates on a tamper. 

 

Battery voltage

 

– The siren monitors 

the battery voltage under load 
conditions and reports a fault  if the 
batteries have approximately one 
month of life remaining. 

 

Jamming

 - If a link is fitted across Jam 

Det, the siren monitors for attempted 
jamming of the radio signal to the 
control unit/expander. See "PCB 
Jumper Details". 

Summary of Strobe Operation 

The strobe operates if the siren self-
activates or if the control unit sends a 
command to activate the strobe. 

After 15 minutes of the siren being 
activated, the strobe flashes at a slower 
rate until the alarm is reset. 

In i-on/Menvier systems, the strobe can 
also be configured using the Set Conf link 
and the 

Strobe on Set/Unset

 

options (see 

"

PCB Jumper Details"

). 

Maintenance 

NOTE: 

Enter the installer code at a keypad 

before opening the lid of the siren. This 
should prevent the sounder from activating. 

However, be prepared in the event that 
the sounder does activate 

– make sure 

that any very loud noise produced 
cannot result in a fall.

  

During routine maintenance, test the siren 
for correct operation, check the tamper 
switch and for any signs of water or insect 
ingress and clean as necessary. Replace 
the batteries every two years or as advised 
by the control panel (see below). See 

Specifications

 for details of the replacement 

battery type needed. 

NOTE: 

Batteries and the unit itself must be 

disposed of in accordance with WEEE 
regulations and any other local or national 
regulations. 

NOTE:

 After removing the existing 

batteries, wait 30 seconds before fitting the 
new batteries. 

To replace the batteries: 

1.  Enter the installer code at a keypad. 

2.  Open the hinged cover that gives 

access to the lid-retaining screw (see 
Figure 2), loosen the screw and open 
the lid. 

3.  Remove the link/terminal cover (see 

Figure 2) by pushing the two retaining 
tabs to the side of the unit while lifting 
the cover. 

4.  Remove the battery connectors from 

the PCB, and remove the batteries. 

5.  After 30 seconds, insert the new 

batteries and connect to the PCB (see 
Figure 1). 

6.  Re-fit the link/terminal cover, close the 

lid, tighten the lid-retaining screw and 
close the screw cover. 

7.  Test the system. 

 

Specifications 

Type of Warning Device:

 External, self-

powered 

Supply Voltage:

 6-7.5V dc; battery low 

warning 4.5V 

Current Consumption:

 0.25mA quiescent 

current including comfort LEDs. 225mA 
in-alarm current 

Sound Output: 

100 dB(A) 

Radio Frequency: 

868.6625MHz narrowband 

Radio Power:

 10mW 

Range: 

Maximum of 500m in free space 

IP Rating: 

Internal components IP65; Case 

IP4X 

Strobe Frequency: 

Double-flash @ approx 1Hz 

Case Material: 

Polycarbonate 

Содержание SDR-REXT

Страница 1: ...er quiet maintenance mode Battery voltage monitoring Lid and rear tamper detection Selectable cut off timer Choice of siren tones Impact resistant polycarbonate construction Table of Contents Installi...

Страница 2: ...displayed while you carry out the next step 4 Connect both batteries in the siren see Figure 1 The control unit should discover the siren and you should see Siren added If you do not see this try agai...

Страница 3: ...r Details for further information Figure 3 Jumpers and Connections Hinged cover for lid retaining screw Link terminal cover Cover retaining tab pull tab each side to release cover Tamper switch Spirit...

Страница 4: ...System Options Jamming option can be set to Off Fault or Tamper Jamming is not reported if Off is selected Please refer to the Engineering Guide for additional information Control units expanders and...

Страница 5: ...siren for correct operation check the tamper switch and for any signs of water or insect ingress and clean as necessary Replace the batteries every two years or as advised by the control panel see bel...

Страница 6: ...teries is SDR R BAT1 Battery Life Typically 2 years Weight 1 2kg without batteries Operating Temperature 25 C to 60 C Max Relative Humidity 95 Dimensions 290mm h x 277mm w x 80mm d SIMPLIFIED EU DECLA...

Страница 7: ...Page 7 NOTES...

Страница 8: ...NTENTS OF THIS DOCUMENT SHALL NOT BECOME PART OF OR MODIFY ANY CONTRACT BETWEEN THE PARTIES In no event will Eaton be responsible to the purchaser or user in contract in tort including negligence stri...

Отзывы: