2 Engineering
2.10 Actuator output
Rapid Link 5 · RAMO5 · RASP5
10/19 MN034004EN
www.eaton.com
61
2.10 Actuator output
The actuator output (M12 connections) enables the control of external
signaling elements or relays.
To do this, pin 4 of the ASi connection must be supplied with an external
voltage of +24 V DC. The corresponding reference point is pin 2 (0V) on the
AS-i connector. The actuator (indicator lamp, relay, valve) can be connected
using Q3 pin 4 (+24 V, max. 1 A). Reference point (0V) is pin 3.
The actuator output is controlled internally; the response time is up to 20 ms.
The permitted length of the connection cable is 20 m.
Maximum load current
•
The maximum permissible load current is 1 A with external power
supply.
•
If there is no external power supply, the maximum permissible load
current is only 100 mA.
The actuator output is short-circuit proof.
In the event of an overload or short-circuit, a group fault signal will be
generated and the Motor LED will light up red to indicate this.
→
Actuator output
An actuator output is only available in the form
RAMO5-xx
1
…-…S1.
RA-XAZ2-1M
AS-I Data
Fault
I1
SEN I1
ACT Q1
Q1
SEN I2
I2
PWR FLT
1
–
2
–
3
0 V Actuator output (Q1)
4
+24 V DC Actuator output (Q1)
5
–
1
3
2
4
5
24 V DC
1
(ASi+)
2
external 0 V
3
(ASi–)
4
external 24 V
2
4
1
3
Содержание Rapid Link RAMO5
Страница 1: ...Manual Rapid Link 5 RAMO5 RASP5 10 19 MN034004EN ...
Страница 4: ...II ...
Страница 10: ...6 Rapid Link 5 RAMO5 RASP5 10 19 MN034004EN www eaton com ...
Страница 122: ...4 Operation 4 3 Manual control 118 Rapid Link 5 RAMO5 RASP5 10 19 MN034004EN www eaton com ...
Страница 136: ...5 RAMO5 Motor starter 5 7 Configure special settings 132 Rapid Link 5 RAMO5 RASP5 10 19 MN034004EN www eaton com ...
Страница 158: ...8 PC tool 8 2 Parameter Editor 154 Rapid Link 5 RAMO5 RASP5 10 19 MN034004EN www eaton com ...
Страница 164: ...9 Control Unit 9 2 Extended parameter set 160 Rapid Link 5 RAMO5 RASP5 10 19 MN034004EN www eaton com ...
Страница 194: ...10 Parameter list 10 4 Parameter groups for RASP 190 Rapid Link 5 RAMO5 RASP5 10 19 MN034004EN www eaton com ...
Страница 208: ...11 Communications 11 5 OP Bus 204 Rapid Link 5 RAMO5 RASP5 10 19 MN034004EN www eaton com ...
Страница 216: ...12 Error messages 12 3 RASP Error list 212 Rapid Link 5 RAMO5 RASP5 10 19 MN034004EN www eaton com ...