When connecting the bypass and load voltage from another model UPS to an Eaton 9390 UPS using the Eaton
Sync Control accessory, use Phase A, Phase B, and Neutral connections from the other UPS. DO NOT connect the
other model UPS Phase C bypass and load voltage to the Sync Control connection point when connecting to an
Eaton 9390 UPS.

TB1

Ground
Terminal

Figure 3‐1. Typical Eaton Sync Control Wiring Terminal Locations

Содержание Powerware 9390

Страница 1: ...Eaton Powerware 9390 160 N 4x0 Sync Control Ea https eaton power ru catalog eaton 9390 9390 160 n 4x0...

Страница 2: ...Eaton 9390 UPS 9395 UPS and 9395 SSBM Sync Control Installation and Operation Manual Sync Control Installation and Operation Manual...

Страница 3: ......

Страница 4: ...Eaton 9390 UPS 9395 UPS and 9395 SSBM Sync Control Installation and Operation Manual Sync Control Installation and Operation Manual...

Страница 5: ...et de maintenance des batteries et de l onduleur Veuillez consulter enti rement ces instructions avant de faire fonctionner l quipement et conserver ce manuel afin de pouvoir vous y reporter ult rieur...

Страница 6: ...ng the Site 2 1 2 2 1 Environmental and Installation Considerations 2 1 2 2 2 Eaton Sync Control Wiring Preparation 2 4 2 3 Inspecting and Unpacking the Eaton Sync Control 2 4 3 Installation 3 1 3 1 I...

Страница 7: ...rol 3 10 Figure 3 8 Eaton 9395 UPS and Plus 1 UPS 450 550 kVA Interface Locations for Eaton Sync Control 3 11 Figure 3 9 Eaton 9395 UPS and Plus 1 UPS 650 825 kVA Interface Locations for Eaton Sync Co...

Страница 8: ...transfer of the load from one load bus to another by means of downstream dual source solid state transfer switches Without the load sync option the two system output critical load buses could become o...

Страница 9: ...a command or option that you type or enter at a prompt S Italic type highlights notes and new terms where they are defined S Screen type represents information that appears on the screen or LCD Icon D...

Страница 10: ...inside the UPS or SBM WARNING S The UPS system contains its own energy source batteries The output terminals may carry live voltage even when the UPS is disconnected from an AC source S To reduce the...

Страница 11: ...scribe S UPS or SBM cabinet optional components and accessory installation instructions including site preparation planning for installation and wiring and safety information Detailed illustrations of...

Страница 12: ...offered as part of the sales contract for the UPS Contact service in advance usually a two week notice is required to reserve a preferred startup date 2 2 Preparing the Site For the Eaton Sync Contro...

Страница 13: ...ol Installation and Operation Manual S P 164000052 Rev 2 www eaton com powerquality 2 2 FRONT VIEW 66 27 26 09 Dimensions are in millimeters inches 61 18 24 09 Four Mounting Holes in Rear of Panel 3 1...

Страница 14: ...rol Installation and Operation Manual S P 164000052 Rev 2 www eaton com powerquality 2 3 LEFT SIDE VIEW RIGHT SIDE VIEW Knockout Holes for 1 Inch Conduit Dimensions are in millimeters inches 20 32 8 0...

Страница 15: ...m 30 to 600V The wire should be rated at 600V 1A minimum and 12 AWG maximum S Sync Control dry contacts are rated at 250 Vac Vdc at 6A per contact maximum load S When installing external wiring betwee...

Страница 16: ...1 Installation and Wiring with an Eaton 9390 UPS NOTE When installing wiring connections conduit must be installed between the Eaton Sync Control and the UPS cabinet To install and wire 1 Install the...

Страница 17: ...e from another model UPS to an Eaton 9390 UPS using the Eaton Sync Control accessory use Phase A Phase B and Neutral connections from the other UPS DO NOT connect the other model UPS Phase C bypass an...

Страница 18: ...ss NO OR J2 5 Industrial Relay Card TB1 1 On Bypass Common 14 AWG Twist Together J2 6 Industrial Relay Card TB1 2 On Bypass NO From UPS System B To Sync Control Function Note TB6 1 TB1 10 Bypass Volta...

Страница 19: ...ut Voltage Phase A UPS System A Output Voltage Phase B UPS System A Output Voltage Neutral or Phase C for SBM UPS System B Output Voltage Phase A UPS System B Output Voltage Phase B UPS System B Outpu...

Страница 20: ...9395 UPS and 9395 SSBM Sync Control Installation and Operation Manual S P 164000052 Rev 2 3 5 TB1 TB2 TB6 Mini CSB Building Alarm Terminal Block P5 Figure 3 3 Eaton 9390 UPS 40 80 kVA Interface Locat...

Страница 21: ...9395 UPS and 9395 SSBM Sync Control Installation and Operation Manual S P 164000052 Rev 2 3 6 TB6 TB1 TB2 Mini CSB Building Alarm Terminal Block P5 Figure 3 4 Eaton 9390 UPS 100 160 kVA Interface Loca...

Страница 22: ...Bypass Voltage Phase B Output Voltage Phase A Output Voltage Phase B Output Voltage Neutral Bypass Voltage Return Phase B TB6 Figure 3 5 TB6 Terminal Block Detail 1 8 P5 BUILDING ALARM 3 BUILDING ALA...

Страница 23: ...locations and assignments termination requirements conduit landing locations and terminal access instructions NOTE Completethe wiring to the X Slot Relay Interface Card or Industrial Relay Card termin...

Страница 24: ...ss NO OR J2 5 Industrial Relay Card TB1 1 On Bypass Common 14 AWG Twist Together J2 6 Industrial Relay Card TB1 2 On Bypass NO From UPS System B To Sync Control Function Note TB6 1 TB1 10 Bypass Volta...

Страница 25: ...164000052 Rev 2 3 10 TB3 TB6 NOTE Interface connections are located in the same positions on the 9395 550 275 UPS 225 550 kVA and the 9395 UPS 300 kVA X Slot Communication Bays Install Relay Interface...

Страница 26: ...S P 164000052 Rev 2 3 11 TB3 TB6 NOTE Interface connections are located in the same positions on the 9395 Plus 1 UPS 225 275 kVA X Slot Communication Bays Install Relay Interface Card in any open bay...

Страница 27: ...Control Installation and Operation Manual S P 164000052 Rev 2 3 12 TB3 TB6 X Slot Communication Bays Install Relay Interface Card in any open bay ISBM SECTION Figure 3 9 Eaton 9395 UPS and Plus 1 UPS...

Страница 28: ...M Sync Control Installation and Operation Manual S P 164000052 Rev 2 3 13 TB3 TB6 X Slot Communication Bays Install Relay Interface Card in any open bay ISBM SECTION Figure 3 10 Eaton 9395 UPS 1000 11...

Страница 29: ...llation and Operation Manual S P 164000052 Rev 2 3 14 Strain Relief Bushing Figure 3 11 Relay Interface Card End View 1 15 K4 Normally Open On Bypass 6 4 K4 Common On Bypass Strain Relief Bushing 5 K4...

Страница 30: ...lock J2 from Relay Contacts to Customer s Monitoring Equipment Figure 3 13 Industrial Relay Card Table 3 3 IRC Wire Terminations IRC Terminal Function Remarks J2 1 NC Normal Mode J2 2 COM J2 3 NO J2 4...

Страница 31: ...for wiring requirements Figure 3 1 shows the Eaton Sync Control TB1 terminal block and ground terminal locations Figure 3 2 shows the TB1 terminal block wiring detail Figure 3 14 shows the typical lo...

Страница 32: ...7 Sync Control Trouble Return 24 Vdc Optional TB4 7 TB1 1 On Bypass Common 14 AWG Twist Together TB4 8 TB1 2 On Bypass NO From SSBM B To Sync Control Function Note TB3 6 TB1 10 Bypass Voltage Phase A...

Страница 33: ...Control Installation and Operation Manual S P 164000052 Rev 2 3 18 X Slot Communication Bays TB1 and TB2 See Figure 3 15 for detail TB4 TB5 TB6 and TB7 TB3 See Figure 3 18 for terminal assignments Fi...

Страница 34: ...M Sync Control Installation and Operation Manual S P 164000052 Rev 2 3 19 TB1 TB2 See Figure 3 17 for terminal assignments Figure 3 15 TB1 and TB2 Interface Terminal Detail TB4 TB5 TB6 TB7 On Bypass F...

Страница 35: ...All building alarm inputs require an isolated normally open or normally closed contact or switch rated at 24 Vdc 20 mA minimum connected between the alarm input and common terminal as shown Building...

Страница 36: ...95 SBM to UPS Interconnection System Control Wiring From SSBM To UPS 1 Function Note TB3 9 TB6 1 Bypass Voltage Phase B 480 Vac 14 AWG Twist Together From UPS 1 To UPS 2 Function Note TB6 1 TB6 1 Bypa...

Страница 37: ...INSTALLATION Eaton 9390 UPS 9395 UPS and 9395 SSBM Sync Control Installation and Operation Manual S P 164000052 Rev 2 3 22 This page intentionally left blank...

Страница 38: ...onization reference to each system Each system uses this reference to regulate the inverter phase relationship so that the two system outputs can maintain synchronization with each other To establish...

Страница 39: ...egardless of the position of the PREFERRED SOURCE SELECTOR switch S Dual redundant logic power supplies are incorporated within the Eaton Sync Control ensuring both systems remain synchronized even du...

Страница 40: ...n the non master system mode NOTE At any given time only one of the UPS systems can be in the non master system mode Figure 4 2 Synchronization Reference Control 4 3 Operation Perform the following pr...

Страница 41: ...cates UPS System A is the active master source This indicator may illuminate even if the PREFERRED SOURCE SELECTOR switch is not set to the corresponding position 4 UPS SYSTEM A SYNCHRONIZED TO LOAD B...

Страница 42: ...ONIZED TO LOAD indicator illuminates for the non master system 5 To disable the automatic synchronization control press the LOAD SYNC ENABLE pushbutton and verify that the indicators including the LOA...

Страница 43: ...OPERATING INSTRUCTIONS Eaton 9390 UPS 9395 UPS and 9395 SSBM Sync Control Installation and Operation Manual S P 164000052 Rev 2 www eaton com powerquality 4 6 This page intentionally left blank...

Страница 44: ...erforms startup and commissioning of the Product b if the Product is moved to a new location by someone other than an authorized Eaton Customer Service Engineer in the USA or Agent outside of the USA...

Страница 45: ...WARRANTY Eaton 9390 UPS 9395 UPS and 9395 SSBM Sync Control Installation and Operation Manual S P 164000052 Rev 2 www eaton com powerquality 5 2 This page intentionally left blank...

Страница 46: ......

Страница 47: ...P 1640000522 P 164000052 2...

Отзывы: