EU5C-SWD-PF2-1
15
06/09 AWB2723-1613en
Installation
The SmartWire-Darwin power module EU5C-SWD-PF2 is
envisaged for mounting on a top-hat rail.
X
Mount the module on the top-hat rail.
X
Connect the 24 V DC voltage to the terminals POW on the
front of the module.
X
If necessary, reconnect the 24 V DC voltage for the
contactor coils to the terminals
AUX
.
X
Connect the 8-pole SmartWire-Darwin cable to the SWD In
socket. The continuation to the next SmartWire-Darwin
module is from the SWD Out socket.
The connection terminals are suitable for cables AWG24 to
AWG16. and flexible cables with a cross section of 0.5 to 1.5
mm
2
.
Figure 4:
Terminal capacity
24V
0V
POW
AUX
24V
0V
AUX
24V
0V
3
A
3
A
3
A
24 V DC
0 V