Parameters
04/10 MN04020001Z-EN
106
Sequence control
The sequence control enables a cyclical program sequence with
the fixed frequency setpoints FF0 to FF7. To run the program you
can also select from four different operating modes and assign
rotation direction (FWD/REV) and run time to the individual fixed
frequencies. The program sequence is programmed in binary code
and is represented by a decimal number for simple entry.
table “P9.10“ shows the parameters of the fixed frequencies
(P10.1 - P10.8) with the associated run times (P10.11 - P10.18)
and the corresponding values in binary and decimal format.
Depending on the selected rotating field direction (FWD/REV), the
decimal value is multiplied by 0 (= FWD) or 1 (= REV). The sum of
all decimal values forms the program number for parameter
P10.10.
Table 9:
Determining the program number (P10.10)
PNU
ID
Access right
RUN
Value
Description
Factory setting
(P1.3)
P10.9
1436
/
PLC Sequence control, operating mode.
0
Selection of operating modes for cyclical program execution.
The start of the program execution via a digital input (DI1 - DI6) is
executed according to parameter P3.21.
The pause of the program execution via a digital input (DI1 - DI6)
is executed according to parameter P3.22.
0
Deactivated
1
Execute program cycle once.
2
Execute program cycle continuously.
3
Execute program cycle in steps.
4
Execute program cycle continuously in steps.
P10.10
1437
/
PLC Sequence control, program (FWD/REV)
0
0 - 255
Summated decimal value from the binary coded program sequence
(see Table xyz1).
Fixed frequency
Values
Example A
Example B
Hz
s
binary
decimal
FWD
REV
(see Figure: 94)
(see Figure: 95)
FF0
P10.1
P10.11
2
0
1
0
1
FWD
0
FWD
0
FF1
P10.2
P10.12
2
1
2
0
1
FWD
0
FWD
0
FF2
P10.3
P10.13
2
2
4
0
1
FWD
0
FWD
0
FF3
P10.4
P10.14
2
3
8
0
1
FWD
0
FWD
0
FF4
P10.5
P10.15
2
4
16
0
1
FWD
0
FWD
0
FF5
P10.6
P10.16
2
5
32
0
1
FWD
0
FWD
0
FF6
P10.7
P10.17
2
6
64
0
1
FWD
0
REV
64
FF7
P10.8
P10.18
2
7
128
0
1
FWD
0
REV
128
Sequence control, program (FWD/REV): P10.10 =
0
192
h
The fixed frequencies (FF0 - FF7) are only active if the run
times (P10.11 - P10.18) of the associated parameters are
set (> 0 s).
Содержание M-Max series
Страница 8: ...04 10 MN04020001Z EN 4...
Страница 12: ...04 10 MN04020001Z EN 8...
Страница 58: ...04 10 MN04020001Z EN 54...
Страница 66: ...04 10 MN04020001Z EN 62...
Страница 138: ...04 10 MN04020001Z EN 134...
Страница 150: ...04 10 MN04020001Z EN 146...
Страница 196: ...04 10 MN04020001Z EN 192...