The pressure filter with change-over valve, type DSF 1201-15001, DSF 1205-10005 are designed for filtration of operating fluids 
according to the technical parameters of the data sheets 2133,  2136 and 2134 (or in case of special design the corresponding 
data sheet). 
 

1. Safety instructions

 

 

-  Prior to operating the filter, manual and maintenance instructions have to be read carefully. 
-  Follow the instructions of this manual under any circumstances! 
-  The manufacturer does not assume liability for any damage, which occurs due to disregarding these instructions. 
-  If operations are carried out differently, the safety of the pressurized device can not be assured!  
-  Operating  conditions  given  in  the  data  sheet,  especially  excess  pressure,  temperature  range  and  operating  fluid,  have  to  be 
  followed unconditionally. Variation of these parameters can cause damage to important pressure holding parts and sealing. Also 
  take in consideration the compatibility of filter components with the operating fluid. 
-  Under working conditions the filter housing is pressurized. Do not try to loosen or remove any part of the filter or the filter housing 
  during operation. The operating fluid could escape at high pressure and high temperatures. 
  This does not a

pply for parts of the decompressed or the turned off side of the filter (see „Maintenance“). 

-  Leaking operating fluid always bears the danger of injuries and burns! 
-  Do not open the filter housing until you made sure it is not pressurized any more! 
-  Touching parts of the filter may cause burning, depending on the operating temperature. 
-  When exchanging the filter keep in mind that it might have operating temperature. Danger of burning! 
-  Always wear safety goggles and gloves when working on the filter! 
-  If you come into contact with the operating fluid please follow the instructions of the fluid manufacturer!!  
- Only use original spare parts. 
 
 

2. Installation

 

 

The filter is supplied and delivered ready to be installed. The fitting position of the filter is vertical. The filter has to be fitted with 
fastening screws in size and amount according to the corresponding fastening bore holes of the filter housings. The fitting of the 
filter has to be carried out in the way that the least possible transmission of tensible forces on the filter housing and the change-
over valve is given. The connection of the pipework has to be made with flanges for pipework. 
Ensure upon assembling that 

 

- no dirt and no impurities of foreign fluids penetrate the filter 
- the connections for input and output are correctly connected to the pipe system 
- the pipe system is connected with the filter; as stress-free as possible 
- the extension to demount and the accessibility to the service elements is guaranteed 

 

Filter with electrical respectively electronical clogging indicators have to be installed according to the unit specific conditions and 
according to the technical parameters of the corresponding data sheets. 
 
 

3. Commissioning

 

 

Before commissioning the completeness of the filter (filter elements and seals) and the cleanness have to be controlled. 
Air bleeding of the controlled filter has to be carried out to the following instructions: 

 

-  The positioning pin of the selector shaft has to be located in the middle position 
-  Opening  of  the  air-bleed  screws  or  air-bleed  connections  (air-bleed  connections  according  to  data  sheet  1651  and 
  connection of suitable airbleeding tubes with coolecting pan for the flow out of the operating fluid 
-  Connection  of  the  unit  volume  flow  (reduced  volume  flow;  from  10  to  50  l/min)  until  bubble-free  operating  fluid  flows  out  of 
  both airbleeding tubes 
-  Disconnection of the unit volume flow 
-  Remove  the  airbleeding  tubes  and  close  the  air-bleed  bore  holes  or  air-bleed  connections  (air-bleed  connections 
  according to data sheet 1651) 
-  Connection to the required filter side at the positioning pin of the selector shaft (see instruction plate at filter) 

 

 

 

4. Change of Elements

 

 

The  changing  of  the  filter  elements  is  necessary  when  raching  the  unit  specific  pressure  difference  respectively  reaching  the 
maximum  pressure  difference  given  by  the  clogging  indicator.    If  there is no unit specific definition, the change of the elements 
should be done at a maximum of  p 6 bar. 
This has to be carried out as follows: 
-  Opening of the pressure balance valve 
-  Switching over the positioning pin from the operating side through the other side 
-  Closing the pressure balance valve 
-  Connect  the  air-bleed  and  the  drain  plug  of  filter  side  to  be  maintained  with  suitable  pipes  and  place  a  collecting  pan  for  the 
  operating fluid flowing out 
-  Opening of the air-bleed and drain plugs of the filter side to be maintained until no more operating fluid flows out 
-  Release of the screws of the lid of the filter side to be maintained and remove the filterlid 
-  Remove the retaining plate for the filter elements (DSF 1201-15001) 
 
 
 
 
 
 
 
 
 
 
 

 

Manual and maintenance instructions 

for INTERNORMEN-Pressure filter, change-over  
DSF 1201-15001, DSF 1205-10005

 

 

Sheet No. 

21631-4B

 

Page 1/2

 

 