Installation 

i-on16 

Page 14 

If you wish run mains cable through the side of the 
case, make sure that they are horizontal for the last 
metre before entering the case. 

Mains Connection 

Figure 28 shows the mains connection. Connect to 
a suitable supply using a double pole disconnect 
(isolation) device in accordance with EN60950-1. 

 

Figure 28. Mains Connection 

Caution:

 Do not apply power at this point. 

Step 4. Connect Wired 
Peripherals 

The end station PCB provides four connectors for 
wired outputs. Each of these outputs is driven by a 
transistor, and is capable of sinking a maximum 
500mA when active. The outputs are 0V when 
active, +12V when inactive. 

Figure 29 shows examples of connecting wired 
peripherals. 

 

Figure 29. Connecting Wired Peripherals 

Remote Loudspeaker (Optional) 

If you wish to add a wired Loudspeaker unit, then 
connect it as shown in Figure 29.  

Wired External Sounders (Optional) 

Wired external sounders differ in their methods of 
connection. Figure 29 shows an example of a 
general method of using the outputs to connect a 
wired sounder. 

It is possible to program the TR terminal on the 
control unit (see Figure 3) as either CC or FSL. Use 

Installer Menu – System Options – Panel Tamper Rtn

By default the terminal is CC. If you program the TR 
terminal as FSL then make sure you connect a 2k2 
resistor in series with the wire to the sounder. 

Note: If you do not wish to connect a wired external 
sounder then leave TR programmed as CC and 
make sure you link TR to 0V on the control unit. 
This prevents the control unit reporting Bell Tamper 
unnecessarily. 

Wired Outputs (Optional) 

Figure 29 shows an example of using the wired 
outputs to drive an indicator LED. 

Fit and connect the I-RC01 (Optional) 

Eaton’s Security Business provides the I-RC01 
relay card for use when connecting the outputs to 
devices that require voltage free contacts on their 
inputs. The I-RC01 is supplied with a short wiring 
loom that provides connections to each relay trigger 
input (see Figure 30). A single wire allows you to 
connect the module to the 12V +ve aux supply in 
order to provide power for all four relays. The 
terminals on the edge of the card provide 
connections to the Normally Open, Common and 
Normally Closed terminals of the relays. 

 

1. Brown - OP1 

4. Blue 

– OP4 

2. Orange - OP2 

5. Red - 12V +ve 

3. Yellow - OP3 

 

Figure 30. Connecting an I-RC01 Module 

Once you have connected the wiring loom of the I-
RC01 to the control unit output terminals then slide 
I-RC01 PCB into one of the two slots provides at 
the side of the control unit case. 

L

N

T 250mA 250V

230V ~50Hz 170mA

0V   0V  12V 12V

0V 12V

A

B

0V 12V

1      2     3      4 TR

14V4

- LS +

AUX AUX

BUS

AUX

OUTPUTS

+LS

-LS

12V +

0V

Tamper I n

Tamper Out

ve

Strobe -ve

Trigger -v e

OP1

OP2

OP3

OP4

NO

NC

C

1

2

3

4

5

I-ON16

I-RC01

0V 12V 1      2     3      4 T R

14V4

- LS +

AUX

OUT PUT S

Содержание i-on16

Страница 1: ...i on16 Security System Installation Guide Issue 9...

Страница 2: ...this book are subject to change without notice This manual applies to i on16 control units with version 4 04 software Please note that i on16 control unit software cannot be updated For Your Safety Th...

Страница 3: ...erals 14 Remote Loudspeaker Optional 14 Wired External Sounders Optional 14 Wired Outputs Optional 14 Fit and connect the I RC01 Optional 14 Output on KEY KPZ01 15 Step 5 Fit and Connect I SD01 Option...

Страница 4: ...i on16 Page iv This page is intentionally blank...

Страница 5: ...d The control unit supports 16 wirefree alarm zones 4 hardwired transistor outputs 16 four button remote controls 16 two button hold up alarm and 16 users When fitted with an optional plug on module t...

Страница 6: ...about the factors affection radio signal strength Siting the Control Unit Do site the unit Upright battery at the bottom Within a protected zone As high as possible However do make sure that the unit...

Страница 7: ...ins for Lid Tamper Figure 2 Control Unit End Station PCB Figure 3 shows the controls and connectors available on the end station PCB 1 Aerials 2 20VAC Input from transformer 3 Battery input 12VDC 4 Ki...

Страница 8: ...fully lever the front of the keypad containing the PCB and display away from the keypad rear housing Figure 5 Opening the Keypad 1 Central keyhole 2 Rear tamper shroud 3 Cable entry 4 Fixing holes Fig...

Страница 9: ...he bottom edge of the caps in with the end of a small screwdriver to start them Remove the two screws hidden underneath see Figure 8 Gently swing the lower side of the front out from the back box by a...

Страница 10: ...mins in alarm The amount of current available from the control unit depends on the battery fitted The current taken by the control unit PCB communicator and keypads is given in Technical Specification...

Страница 11: ...ty of the cable screen is most important and screens MUST be continuous along the full length of the cable 3 If the cable enters any metal enclosure ensure the screen is isolated from the case Cable S...

Страница 12: ...ic products the control unit contains components that are sensitive to static electricity Try not handle the PCB directly If you must handle the PCB take the standard precautions against damage by sta...

Страница 13: ...the backplate is level and mark drill and plug at least three fixing holes Screw the backplate to the wall through the fixing holes using the M4 screws Figure 17 Screw KEY K01 KP01 KPZ01 Back Box to...

Страница 14: ...ress for the keypad by placing a jumper on the appropriate address pins see Figure 19 8 Connect the new keypad see Figure 18 9 Close the keypad and ensure that the tamper switch is closed Backlight Co...

Страница 15: ...Backlight Settings 1 Enter Local Programming mode see above MENU 2 Press The display shows the current status of the backlight LEDs for example MENU 3 Press repeatedly to select one of the following B...

Страница 16: ...l mains equipment Note Do not site the external prox reader closer than one meter to any other kind of prox reader for example an i kp01 KEY KP01 KPZ01 or another external prox reader If you do so the...

Страница 17: ...select the wiring type for the keypad zones use Installer Menu System Options Wired Zone Type All Zones Alternatively to select the wiring type for an individual keypad use Installer Menu Detectors De...

Страница 18: ...ect a 2k2 resistor in series with the wire to the sounder Note If you do not wish to connect a wired external sounder then leave TR programmed as CC and make sure you link TR to 0V on the control unit...

Страница 19: ...quipment continues to comply with the safety regulations to which it was approved 1 SELV terminals 2 TNV terminals Figure 32 SELV and TNV Terminals CAUTION Make sure that the end station is not powere...

Страница 20: ...bottom of the control unit see Figure 36 Figure 36 Fitting the Battery Make sure that you secure the battery to the case with the strap provided Connect the battery leads red to the positive black to...

Страница 21: ...pplied with each detector or peripheral 2 Install detectors and peripherals at their selected locations 3 Use the Installer Menu Test option to a carry out a walk test of the detectors b test the oper...

Страница 22: ...s on the bottom line for example You can press or to display the other sub options Leaving the Installer Menu If you wish to leave the Installer Menu at any time 1 Press until the display shows the wo...

Страница 23: ...Menu without changing defaults The system loads all defaults except for Access Codes and the Log see Note The display returns to the Installer Menu Note The log is protected and cannot be erased by th...

Страница 24: ...el Loudspeaker Volume Entry Alarm Delay Abort Time Supervision Jamming Force Set Tamper Omit CSID Code Silence Alerts Mains Fail Delay Set Date Time Panel Tamper Rtn 5COMMUNICATIONS 10 ARC Reporting 1...

Страница 25: ...ft dry cloth Do not use water solvents or any proprietary cleaning materials Walk test the detectors Test any external sounders and strobes Replacing or Removing Wired Keypads If you need to remove or...

Страница 26: ...n which they are installed As a guideline most transmitters will work up 200m range in free space conditions Communications Uses plug on modules with proprietary interface between control unit and mod...

Страница 27: ...EUR 00 Two button HUD tilt switch transmitter 710rEUR 00 Two button HUD 726rEUR 50 Long range hand held HUD 726rEUR 60 Short range hand held HUD Detectors 713rEUR 00 Pet tolerant PIR 714rEUR 00 PIR Tr...

Страница 28: ...the control unit into a special mode where the tamper switch controls the recording and playback of the current message Use this mode if the end station is an inconvenient distance from the keypad 1 S...

Отзывы: