Communications Menu
Page 91
Messages
Specify the text for the Home Message and for the additional four messages (Message 1-
4). The Home Message can have up to 12 characters. Message 1-4 can have up to 30
characters.
Triggers
For each Message 1-4, specify the event categories that you want to associate with the
message. You can choose one or more of the following:
Alarms
Includes all types of alarm, including 24 hour, Fire, HUA, Burg, test zone fail, Zone
Alarm, Zone Follow, Social Emergency, Social Inactivity and Medical. This also
includes restores from those alarms. See page 38 for details of how Zone Alarm and
Zone Follow are configured.
Tampers
Includes all types of tampers, including system, sensor, user code (excess digits),
siren, WAM and radio keypad.
Sets/Unsets
Includes any type of setting, part-setting or unsetting of a partition (or part set).
System
Includes any type of system event that is not an alarm, tamper or set/unset. This
includes jamming, supervision fail, communications failure or fault, AC lost, low or
missing system battery, low battery on radio device and Aux 12V fail.
Destinations
Use this option to specify the recipients of the reports:
1.
Select a Message 1-4.
2.
Select one of the four recipients. Each Message 1-4 can have up to four recipients.
3.
Select a contact from the Contacts List (page 80), then one of the two telephone
numbers defined for that contact.
4.
If required, repeat the process from step 2 to specify additional recipients for the
message.
5.
If required, repeat the process from step 1 for another Message 1-4.
Incoming
If the control unit uses a GSM plug-in module, users can change or query the status of the
control unit using commands contained within SMS text messages sent from a mobile
phone or other messaging device. This feature can, for example, be used to set/unset the
system, activate/deactivate outputs, omit/un-omit zones or query the current status of the
system. For full details of the commands, please refer to the SMS Command Messaging
User's Guide.
Remote Control
Enables the feature.
Forwarding
Enables you to configure the control unit to forward SMS messages received from
the network provider (such as low-credit warnings) to a specified telephone number.
When you select Forwarding, the Contacts List (page 80) is displayed. Select a
contact from the Contacts List, then one of the two telephone numbers defined for
that contact.