Settings Options and Partitions Menus
Page 53
PZ Set Response
Specifies the system response for activations of zones of type Perimeter in the set state.
In a partitioned system, each partition can have different response. In a part-setting
system, this option applies to the complete system.
Note:
For a part-setting system, this option appears in
System Options
.
Silent
Activation inserted into non-mandatory log.
No internal sounders.
Outputs of type Perimeter and Perimeter Timer activate.
Outputs of type Perimeter Timer deactivate on expiry of
PZ Reset Time
(see below)
or code entry.
Internal
Activation inserted into non-mandatory log.
Internal sounders activate.
Outputs of type Perimeter and Perimeter Timer activate.
Internal sounders silenced by user code, etc.
Outputs of type Perimeter Timer deactivate on expiry of
PZ Reset Time
(see below)
or code entry.
Siren
Activation inserted into non-mandatory log.
Internal and external sounders activate.
Outputs of type Perimeter and Perimeter Timer activate.
Internal and external sounders silenced by user code, etc.
Outputs of type Perimeter Timer deactivate on expiry of
PZ Reset Time
(see below)
or code entry.
Full
Activation inserted into non-mandatory log.
Internal and external sounders activate.
Outputs of type Perimeter and Perimeter Timer activate.
Communications active.
Internal and external sounders silenced by user code, etc.
Outputs of type Perimeter Timer deactivate on expiry of
PZ Reset Time
(see below)
or code entry.
Communications restored by user code entry.
PZ Reset Time
This determines the maximum period of time that outputs of type Perimeter Timer will be
active.
In a partitioned system, each partition can have different reset time. In a part-setting
system, this option applies to the complete system.
The reset time can be set from 0-999 seconds. Setting the time to 0 requires a user to
enter a code to deactivate outputs of type Perimeter.
Note:
For a part-setting system, this option appears in
System Options
.