Test Menu 

Page 103 

Recipients 

Use this option to specify the telephone numbers and/or IP addresses to use to send 
messages to the ARC. You do this by selecting contacts from the Contacts List (page 
102)

Tel. Recipient 1  

 

If you want to send messages to the ARC by telephone, select a contact from the 
Contacts List, and then either the first or second telephone number defined for that 
contact. Otherwise, select None if you do not want to send messages to the ARC by 
telephone.  

Tel. Recipient 2 

 

You can specify a second telephone recipient in the same way as for Tel Recipient 1. 
The control unit can use the second recipient only if 

ARC Reporting 

– Call Mode

 is 

set to Alternate. 

IP Recipient 1 

 

If you want to send messages to the ARC over Ethernet, select a contact from the 
Contacts List, and then specify the port number (default 2749). The control panel 
communicates with the ARC using the IP address of the selected contact and the 
port number. Select None if you do not want to send messages to the ARC over 
Ethernet.  

IP Recipient 2 

 

You can specify a second IP recipient in the same way as for IP Recipient 1. The 
control unit can use the second recipient only if 

ARC Reporting 

– Call Mode

 is set to 

Alternate. 

Account Numbers 

Use this option to store an ARC account numbers. 

If you are configuring a partitioned system, the control unit gives you the opportunity to 
store an account number for each partition. If you are configuring a part-setting system, 
you can store one account number. 

With CID reporting, the system reports alarms using a four-digit account code. 

With Fast Format and SIA reporting, you can use four-, five- or six-digit codes. The control 
unit pads five-digit codes to six digits using a leading zero. The control unit leaves four- 
and six-digit codes unchanged. 

Note:

 If you need to add a letter to the account code, press the numbers keys repeatedly 

until the letter you want appears on the display. See page 19. 

Report Type 

Use this option to choose the report type to send to the ARC. 

The report types available are: Fast Format, Contact ID, SIA 1, SIA 2, Scancom SIA 3, 
Extended SIA 3 and Extended SIA3 v2. 

Fast Fmt Channels 

(See Appendix A for a brief description of Fast Format.) 

Note:

 Eaton does not recommend using the i-gsm02 for Fast Format communications. 

The GSM network introduces too great a variation in the delay between signal and 
response. Tests carried out by Eaton show that different cell towers from the same 
providers give different results. 

Содержание i-on Series

Страница 1: ...i on Next Generation Security System Engineering Guide Issue 1 Control unit software version 5 0...

Страница 2: ...tal loss of power additional expenses in the use of existing power facilities or claims against the purchaser or user by its customers resulting from the use of the information recommendations and des...

Страница 3: ...es 11 Chapter 2 Planning the Installation 12 Choosing the installation locations 12 General requirements 12 Control unit 12 Keypads and proximity readers 12 External sirens 13 Checking power availabil...

Страница 4: ...27 On board radio detectors 27 Detectors attached to an expander 28 Chapter 5 Installer Menu Map 31 Chapter 6 Detectors Devices Menu 41 Detectors 41 Add Del Detectors 41 Program Zones 41 Address Bus...

Страница 5: ...5 PZ Set Response 76 PZ Reset Time 76 Siren Delay 77 Siren Time 77 Strobe on Set 77 Strobe on Unset 77 Part Set Exit Mode 78 Pt set Settle Time 78 Part Set Exit Time 78 Pt set Entry Time 78 Pt set Ala...

Страница 6: ...88 Unconfirmed Reset 88 Confirmed Reset 89 HUA Confirm Time 89 Tamper as Tamper Only 89 Masking 89 Alarm response when the system is unset 90 Alarm response when the system is set 90 Mask Override 91...

Страница 7: ...Account Numbers 103 Report Type 103 Fast Fmt Channels 103 CID SIA Events 105 Restorals 109 Burg Comms Rearm 109 21CN FF Ack Time 109 Send Tamp As Burg 109 Dynamic Test Call 109 Static Test Call 110 U...

Страница 8: ...123 Wired Sirens 123 Wired Keypads 123 KEY RKPZ 123 Internal Sounders 123 Wired Keypad 123 Radio Keypads 124 i rk01 124 KEY RKPZ 124 Expanders 124 Radio and wired expanders 124 EXP PSUs 124 Walk Test...

Страница 9: ...ast Format 134 Contact ID 134 SIA 1 SIA 2 SIA 3 and Extended SIA 3 135 Extended SIA3 V2 135 Appendix B System Maintenance 136 Inspections 136 Replacing or removing devices 136 Removing a plug on modul...

Страница 10: ......

Страница 11: ...able to provide additional zones and outputs Summary of features The i on Next Generation range of control units feature Support for a wide range of peripheral devices including keypads detectors exte...

Страница 12: ...robe connections Yes Yes Max custom outputs 4 4 Max outputs system wide Note 5 30 40 Ports Ethernet port Yes Yes USB port Yes Yes On board loudspeaker connections 1 1 Micro SD card slot Yes Yes Device...

Страница 13: ...ts and outputs provided by expanders keypads and other peripherals It does not include plug by outputs Note 6 The maximum number of on board zones is for Fully Supervised Loop FSL or 2 wire Closed Cir...

Страница 14: ...han one partition may produce un expected results for users of the system When designing a system note that a zone will only be armed when ALL of the partitions that it belongs to are set If a user un...

Страница 15: ...ader KEY KPZ01 Wired keypad with built in proximity reader two on board zones one programmable output and terminals for a KEY EP external proximity reader KEY RKPZ Two way battery powered radio keypad...

Страница 16: ...allows the control unit to send recorded speech messages and also report alarm information using standard protocols such as Fast Format SIA and Contact ID This module also allows remote maintenance o...

Страница 17: ...ing is used this may reduce the available number of zones see page 15 Radio detectors Radio detectors can communicate directly to control units that have built in radio communications or to radio expa...

Страница 18: ...expander also supports Two i rk01 one way radio keypads Two external radio sirens Two internal radio sounders Two Wireless Accessory Modules WAMs One wired loudspeaker The maximum number of expanders...

Страница 19: ...to be installed Connecting the control unit to a network through the Ethernet port allows you to Configure the control unit and update firmware using the web interface see page 23 Communicate alarm in...

Страница 20: ...d unsetting tones The loudspeaker must have an impedance of 16 Ohms You must not connect two loudspeakers in parallel to the same port Cameras You can configure the system to store images from a netwo...

Страница 21: ...11 Other supported radio devices The following additional radio devices are also supported DET RSURV01 Radio Site Survey Tool 770REUR 00 Wireless Accessory Module WAM 762REUR 00 Radio receiver 768REUR...

Страница 22: ...ations Control unit The control unit must be located Within the protected area but not in an entry or exit zone Upright battery at the bottom on a wall or other flat surface to discourage tamper attem...

Страница 23: ...der the use of remote power supplies see pages 10 and 18 When considering the power drawn include the control unit s PCB and all peripherals powered by the control unit including any output devices 12...

Страница 24: ...ovide the charge required by the above example to meet Grade 2 requirements Detector zone wiring types Before installation you need to choose the wiring type method to use for any wired detectors Full...

Страница 25: ...as shown in Figure 3 The detector must signal masking by closing both the Alarm and Fault contacts together If the detector closes the Fault contact only the control unit reports this as a detector f...

Страница 26: ...able to mains earth at the control unit but not at the keypad or expander 2 The continuity of the cable screen is most important and screens MUST be continuous along the full length of the cable 3 Whe...

Страница 27: ...the ends of the longest cables Figure 4 Figure 4 Bus Termination Voltage drop In order for the system to work correctly the voltage at each device must NOT drop below 10 5V even when running on the s...

Страница 28: ...63V 2 18V 2 72V 3 26V 3 81V 4 35V 4 90V 5 44V 360mA 0 58V 1 15V 1 73V 2 30V 2 88V 3 46V 4 03V 4 61V 5 18V 5 76V 380mA 0 61V 1 22V 1 82V 2 43V 3 04V 3 65V 4 26V 4 86V 5 47V 6 08V 400mA 0 64V 1 28V 1 92...

Страница 29: ...es Detectors menu takes you back to the Detectors Devices menu The section starting on page 31 shows a menu map which gives the position of all menus and options in the Installer menu Entering text Yo...

Страница 30: ...dinarily the control unit starts only after the mains supply is switched on even if a battery is connected If you want to operate the control unit temporarily using only the battery or a 12VDC supply...

Страница 31: ...select 2 wire FSL 2k2 4k7 as the wiring type 9 Specify an installer code When prompted confirm the code DO NOT FORGET THIS CODE 10 You will see one of the following If the lid of the control unit is...

Страница 32: ...annot enter a Set Only user code 4 The bottom line displays Detectors Devices which is the first option in the menu 5 Press or to display the next option in the menu then press or to select that optio...

Страница 33: ...le to registered users through www touchpoint online com The settings and options provided through the web interface or Downloader have the same behaviour as those provided through the keypad Before y...

Страница 34: ...ting access codes You can use the Reset Codes link in the control unit s PCB to reset the user 001 and installer codes in the event that either has been forgotten Note Resetting the codes also deletes...

Страница 35: ...i on30R 03 to 50 i on40H 04 to 50 The maximum number of devices on the bus is shown in Table 1 on page 2 Figure 6 shows an example of bus device addressing Figure 6 Bus Device Addressing Example Note...

Страница 36: ...Outputs attached to a bus device take the address An dd oo e g W1 03 01 where A One or more letters showing the device type K keypad W Wired Expander R Radio Expander n Bus number always 1 dd Bus devi...

Страница 37: ...r Address Zone Number FSL and 2 wire CC wiring PAN Z00 to PAN Z09 000 to 009 4 wire CC wiring PAN Z01 to PAN Z05 001 to 005 If an ADP 10CC board is used ten 4 wire CC zones can be used instead of ten...

Страница 38: ...EXP R10 Device number 06 Address R1 06 Detector Address Zone No Detector Address Zone No Detector Address Zone No W1 04 00 040 W1 05 00 050 R1 06 00 060 W1 04 01 041 W1 05 01 051 R1 06 01 061 W1 04 0...

Страница 39: ...i on30R 59 57 55 etc i on40H 79 77 75 etc Zone availability for keypads It is possible that there may be no zones available to assign to a keypad This can happen in two ways When the control unit has...

Страница 40: ...Addressing and Zone Numbering Page 30 Figure 9 Example zone availability i on30R...

Страница 41: ...e all Panel Zone nnn Delete all Delete all Program Zones Zone 000 Name Zone nnn Type Not used Partitions None Visible only in a partitioned system and when zones have a type other than Not Used Attrib...

Страница 42: ...4 Full Set OR Part Set D in a Part Setting System Zones Disabled Visible only when a suitable keypad is fitted Wired Zone Type 2K2 4K7 Loudspeaker Volume Buzzer Volume Backlight External Prox Disable...

Страница 43: ...WAMs Add Del WAM Edit WAM Cameras IP Cam 1 Camera Triggers None Zone Follow Zone Alarm Trigger Partitions All Partitions Visible only in a partitioned system IP Address HTTP Port Internal 80 2 Output...

Страница 44: ...lt O P11 Technical Alarm O P12 Alarm Abort Polarity Normal Pulsed No Partitions All outputs allocated to all Partitions Visible only in a partitioned system Zones None Delay 0 seconds Visible when Pul...

Страница 45: ...minutes Strobe on Set Off Strobe on Unset Off Part Set Exit Mode Instant Set Pt set Settle Time 15 seconds Visible only if Part Set Exit Mode is Final Door Lock Set or Exit Terminate Part Set Exit Ti...

Страница 46: ...e only if Confirmation Mode is Basic Zone tampers Grade 2 Yes System tampers No Confirmation Confirmation Mode DD243 Not available for EU control units which use Basic Confirmation BS8243 Default for...

Страница 47: ...rtitioned system Entry Alarm Delay Yes Abort Time 120 seconds Supervision Tamper Jamming Tamper Force Set Off Tamper Omit Disabled CSID Code 0000 Silence Alerts User Code Mains Fail Delay 0 minutes Se...

Страница 48: ...fitted and Report Type is Fast Format Send Tamp As Burg Disabled Visible only when Report Type is SIA or CID Dynamic Test Call Enabled Visible only if Static Test Call is disabled Static Test Call Di...

Страница 49: ...Serial Number Blank Connection Type Remote Local Rings to Answer 5 rings Answer on one ring Disabled Access Mode Call Out Only Phone Book Tel No 01 Blank Tel No 02 Blank IP Network IP Address 1 Blank...

Страница 50: ...Outputs Radio Outputs Wired Outputs Plug by outputs Expander Outputs Remotes User Hold Up Alarms Prox Tags ARC Reporting Panel Ethernet Module Speech Dialler SMS Email PSU Current Panel External PSU V...

Страница 51: ...s Default zone This deletes the ID of the detector and sets all the zone configuration to default values Note The deletion takes place immediately and not when you leave the Installer menu When you de...

Страница 52: ...larm zones first followed by Fire and then all other alarm types The control unit always processes alarms before alerts Not Used NU 00 The alarm system will not respond when an event triggers this det...

Страница 53: ...that zone to behave like a Final Exit zone if the user part sets the system See page 78 Technical Alarm TA 07 Use this zone type when you want to monitor equipment for example a freezer without raisi...

Страница 54: ...a power supply unit triggers a zone with this type the control unit treats this in a similar way to a mains fail at the control unit itself The action taken depends on the values programmed into Syste...

Страница 55: ...grammed communication but does not generate an alert until the system is unset This zone type is not available for radio zones Log Only LO 17 When a detector triggers a zone with this type the control...

Страница 56: ...tting when the system or partition exit mode is Lock Set see page 73 This zone type is designed for a normally open switch one that is open when the lock is locked Note that this zone type is armed du...

Страница 57: ...set only when all the partitions it belongs to are set Press or to scroll through the list of partitions followed by or to assign de assign the zone to each partition as necessary An All Partitions o...

Страница 58: ...PSU Fault Y Y Y Ext WD Fault Y Y Y HUD Fault Y Y Y Log Only Y Y Y Y Exit Terminate Y Y Y Y Shunt key Latching Y Y Shunt Key Non Latch Y Y Lock Set Y Y Occupancy Y Y Security Y Y Tamper Return Y Y Y Y...

Страница 59: ...Set C Not visible in a partitioned system When a user sets part set C the control unit sets only those zones where Part Set C attribute Yes Part Set D Not visible in a partitioned system When a user...

Страница 60: ...attribute if you have connected a latching type of shock or vibration sensor to a zone You will also need to program an output of type Shock Sensor Reset The control unit ignores the zone during sett...

Страница 61: ...bus device that it has learned To keep the list up to date the control unit scans the bus during power up and when you leave the Installer menu You can also scan the bus by pressing when you see the...

Страница 62: ...this manually by pressing the Request Delete Address button while applying power to the expander or by using Delete Expander page 53 Use the Detectors Devices Address Bus Device to give an EXP PSU a b...

Страница 63: ...XP PSU If you select Enabled the control unit will start an alert if battery 2 is missing or has low voltage If you select Disabled the control unit will ignore the presence or absence of battery 2 De...

Страница 64: ...e will not need any further configuration Note If you replace a radio expander you must teach the identity of the new radio expander to any receivers such as 762s 768s or WAMs that had previously lear...

Страница 65: ...you to program the A B C and D quick set keys In a part setting system you can enable the quick set keys to full set the system or part set part sets B C and D In a partitioned system you can enable a...

Страница 66: ...light Use this option to control the brightness of the backlight on keypads such as the KEY KPZ01 and KEY FKPZ Mode This controls whether the backlight is on or off This can be set to Timed The backli...

Страница 67: ...d reconnect a new keypad of the same type to the bus When you power up the control unit again the remaining keypads will show an alert that the old keypad has been disabled Select Replace Keypad again...

Страница 68: ...t Keypads Name To assign radio keypads to one or more of the partitions if available From the i rk01 menu select Edit Keypads Partitions Once you have entered the Edit Keypads Partitions option press...

Страница 69: ...d menu contains the following options Name To change the keypad s name which appears in reported reports faults or other events Partitions partitioned system only To assign the keypad to partitions Th...

Страница 70: ...configuration The control unit assigns the bus device address of the keypad you removed to the new keypad along with the name and other settings from the old keypad The new keypad will not need any fu...

Страница 71: ...r module the WAM repeats the signals from any detectors within its range amplifying them to a level that the control unit can detect This allows you to increase the area covered by radio detectors Not...

Страница 72: ...arm Hold Up Alarm Burglar Alarm Technical Alarm 24 Hour alarm Perimeter Duress Code Tampers Full Set Part Set Unset Zone Follow Zone Alarm Zone Follow This is displayed only if Camera Triggers Zone Fo...

Страница 73: ...ear on the keypad display Not Used 00 The output is never active Fire Alarm 01 Active when the control unit starts a fire alarm Hold Up Alarm 02 Active when the control unit starts a hold up alarm Bur...

Страница 74: ...depends on the value programmed in System Options Mains Fail Delay see page 98 Battery Fault 13 Active when the control unit detects a fault with its backup battery or a zone of type External PSU Batt...

Страница 75: ...l alarm a hold up alarm or a fire alarm the siren has a distinctive tone during a fire alarm The control unit deactivates this output at the end of the siren time See page 75 to choose the siren durat...

Страница 76: ...ms it after an alarm The output is active for 10 seconds Full Set Ready 32 Active when no detectors are reporting alarm signals Full Set 33 Active when the system is full set If the system is partitio...

Страница 77: ...en you select this type you can choose Polarity See page 69 Latched When set to No the output changes state when activated but then returns to the normal state again after the period specified by On T...

Страница 78: ...is activated and deactivates the output when a Lock Set zone is deactivated Burg Confirm timer 50 Not available on EU control units Operates only when BS8243 or DD243 is enabled Active when a Burg con...

Страница 79: ...Set exit mode Chime Tone Mimic 73 Active when any zone with a chime attribute is active Alert Active 74 Active when the LEDs around the navigation key on a keypad are red The control unit deactivates...

Страница 80: ...and keypads if applicable Select the device that contains the output you wish to program and then one of the following Panel Select one of the following options as displayed on the top line of the di...

Страница 81: ...r each custom output which can be All AND or Any OR For the AND mode all inputs to the custom output must be active for the custom output to be active For the OR mode any one of the inputs must be act...

Страница 82: ...Note By default a FOB 2W 4B Set button instant sets its assigned partition regardless of the exit mode chosen in the Installer menu To program the FOB 2W 4B to follow the exit mode programmed in the I...

Страница 83: ...unit sets the system and converts the Final Exit zone in the set partition to a zone of type Normal Alarm Unsetting When a user de activates the Lock Set zone the control unit converts any zone origin...

Страница 84: ...xit Mode is set to Timed Set or Silent Set The exit time can take any value between 10s and 120s Entry Time The entry time can take any value between 10s and 120s The entry time you select in this opt...

Страница 85: ...tem Note For a part setting system this option appears in System Options Silent Activation inserted into non mandatory log No keypad and internal sounders Outputs of type Perimeter and Perimeter Timer...

Страница 86: ...ad and internal sounders silenced by user code etc Outputs of type Perimeter Timer deactivate on expiry of PZ Reset Time see below or code entry Siren Activation inserted into non mandatory log Keypad...

Страница 87: ...to Siren Time This option changes the length of time that the system operates the siren and sounders during an alarm Note This applies to a siren wired directly to the control unit Radio sirens have...

Страница 88: ...and have the Part Set attribute act as Normal Alarm zones during part setting Pt set Entry Route This option controls how the system treats Entry Route zones when the system is part set Entry Route I...

Страница 89: ...rminate Calendar Set This allows you to configure the control unit to set or unset the alarm system or parts of it at fixed times of day on a seven day cycle If the system is a part setting system you...

Страница 90: ...you specify a start time that is less than 10 minutes from the current time shown by the control unit clock that is less than the period set by Warning Time the event will not take action until the fo...

Страница 91: ...fault name Exception Start Time Specify the time you want the exception to start then to display the next prompt The time 00 00 is midnight at the beginning of a new day Exception Start Date Specify t...

Страница 92: ...a calendar set in this way a total of three times After the third deferral the control unit sets the system Note that deferring setting does not defer any unsetting events Setting Faults If there is a...

Страница 93: ...s at the same time This option applies to all keypads both radio and wired and is not affected by allocating keypads to specific partitions Select Yes to make the HUA keys functional Select No to disa...

Страница 94: ...etting mode programmed for it in Partitions or Setting Options see page 72 Duress Enable Selecting Yes allows master users to assign the Duress user type to users A duress code can set and unset the s...

Страница 95: ...larm abort period does not apply Note This setting is required for INCERT approval A system tamper can be caused by for example Operating a lid back tamper switch on a device Applying a voltage higher...

Страница 96: ...options additional options are displayed to define the meaning of a confirmed alarm If the first unconfirmed alarm is caused by the expiry of the entry timer then for DD243 A further two zones that ar...

Страница 97: ...The option determines whether the user can unset the system by entering an access code after opening the entry door Select one of the following Off The user can enter an access code at the keypad aft...

Страница 98: ...No sounders or sirens Confirmed alarm the control unit waits for any Siren Delay and then starts both internal sounders and external sirens These both run for the Siren Time Siren On Unconfirm The con...

Страница 99: ...Tamper as Tamper Only This is available for only for UK control units and when Confirmation Mode is set to BS8243 The purpose of the option is to ensure strict compliance with BS8243 when reporting t...

Страница 100: ...e 85 Note There is a delay of about three seconds before the control unit starts the alert at the keypad This delay is intentional and is designed to confirm that the fault is a true fault and not the...

Страница 101: ...ecify the zones you want to include in that shunt group Note that it does not matter which partition the zone belongs to the user with the necessary Shunt Code see below will be able to shunt that zon...

Страница 102: ...he IDs for learned radio devices Scroll through the list of devices and select Yes for each type you want to delete then press to action your selection The Keypads option deletes one way radio keypads...

Страница 103: ...e display in the standby screen such as your company name See page 19 for editing text Remote Needs Entry This option relates to the use of remote controls when unsetting a full set system or full set...

Страница 104: ...part set partition Enabled The user must first trigger a Final Exit zone and start the entry timer before unsetting a part set system or partition with a radio keypad The system unsets those partitio...

Страница 105: ...udspeaker can belong to one or more partitions Entry Alarm Delay Use this option to determine what the system will do if a user strays from an Entry Route zone during entry This option is available to...

Страница 106: ...ming also activate See page 89 If there is no Tamper channel allocated in Fast Format the system sends an unconfirmed alarm Note that the Tamper option is required in Grade 2 systems to comply with PD...

Страница 107: ...remote user tries to set the system the control unit will temporarily ignore the remote user Tamper Omit If a user omits a zone it may be necessary also to omit the tamper belonging to that zone Enab...

Страница 108: ...conds to the ARC If mains is restored within that time the control unit switches off the red LEDs deactivates the General Fault outputs and logs Mains Restore If a mains interruption lasts for longer...

Страница 109: ...it provides different methods of reporting to the ARC For mains fail reporting each method differs in the detail that it can send SIA CID reports can indicate mains failure in individual partitions Fa...

Страница 110: ...and the battery is exhausted Note The internal clock adjusts itself for daylight saving in Spring and Autumn SNTP Time Sync You can use this option to keep the time at the control unit synchronised wi...

Страница 111: ...User menu or web interface and change the level 4 user name and code The default user name is Level4 A level 4 user cannot perform other tasks such as to set or unset the system omit zones etc Panel U...

Страница 112: ...fails the control unit re attempts the connection up to a maximum of 15 attempts Alternate The control unit will attempt to contact the ARC using Tel Recipient 1 or IP Recipient 1 depending on Teleco...

Страница 113: ...the second recipient only if ARC Reporting Call Mode is set to Alternate Account Numbers Use this option to store an ARC account numbers If you are configuring a partitioned system the control unit g...

Страница 114: ...arm 15 Zone Omit Setting see note 2 04 Open Close 16 Zone Omit System 05 Alarm Abort 17 General Fault 06 Technical Alarm 18 Masking 07 Confirmed Alarm 19 Zone Shunt 08 RF Low Battery 20 Duress Code 09...

Страница 115: ...he CID SIA codes included in each report group When you enable a Report Group you are enabling the control unit to send any of the telegrams in that group CID SIA alarm transmissions will take conside...

Страница 116: ...338 Ext Siren WAM low battery fail and restore RF Battery PSU 338 External PSU low volts via zone n Faults 342 External PSU AC fail and restore Faults 344 Jamming fail and restore RF Jamming 351 Comm...

Страница 117: ...lar Alarm BZ Zone supervision fail and restore Radio keypad supervision fail and restore External siren supervision fail and restore Internal radio sounder supervision fail and restore WAM supervision...

Страница 118: ...amper and restore Internal sounder tamper and restore WAM tamper and restore Tampers TA TR WAM trouble and restore Faults UA UR Technical alarm and restore Technical Alarm UA UR Perimeter and Perimete...

Страница 119: ...ry time 21CN FF Ack Time This menu appears only if you select Fast Format in Communications Report Type The menu does NOT appear if a GPRS or Ethernet module is fitted A PSTN line connected to a BT21C...

Страница 120: ...with a flood of test calls from systems that have all been given the same time Select Communications ARC Reporting Static Test Call Disabled to disable static test calls Unset Comms Use this option t...

Страница 121: ...e you can use any of the following options Record Message Press to start recording The control unit starts recording from the module s built in microphone The display shows a progress bar indicating h...

Страница 122: ...edge If the called party answers a speech dialler call they can end the call by sending back a DTMF 9 Enabled The control unit ends the call when it receives a DTMF 5 or 9 If the control unit does not...

Страница 123: ...of setting part setting or unsetting of a partition or part set by either keypad remote control or keyswitch System Includes any type of system event that is not an alarm tamper or set unset This incl...

Страница 124: ...Own Telephone No This option appears when you select either of the UCP protocols The option allows you to record the telephone number that originated the SMS message This number is visible to the rec...

Страница 125: ...or missing system battery low battery on radio device and Aux 12V fail Destinations Use this option to specify the recipients of the reports 1 Select a Message 1 4 2 Select one of the four recipients...

Страница 126: ...ns path from the control unit before it generates an alert actives communications and activates line fail outputs You can specify different settings for Ethernet plug by and plug on module communicati...

Страница 127: ...y the IP Subnet Mask Gateway IP Address and DNS IP Address Note Changes take place only after you exit the Installer menu If you are using DHCP use About Panel About Comms IP Address to find out the I...

Страница 128: ...to configure settings to use a dynamic DNS DDNS server which will keep track of any changes to the external IP address of the control unit s internet connection as supplied by the internet service pr...

Страница 129: ...loader from the User Menu To use both the speech dialler and remote dial in access from Downloader fit a SIM card that permits both voice and data traffic Note that when setting up a remote connection...

Страница 130: ...control unit answers after the first ring Note When using Answer on One Ring set the number of rings in Rings to Answer to a higher number than that used by the equipment sharing the telephone line w...

Страница 131: ...mmunicate with the control unit over an IP network This menu allows you to store two IP addresses that the control unit can use to connect to a PC running Downloader The user starts the call by select...

Страница 132: ...procedure is repeated every 24 hours for 5 days then every 48 hours for a further 5 days up to a maximum of 30 retries If no successful connection is achieved the keypad displays a remote service fai...

Страница 133: ...Loudspeakers You can use this option to test any loudspeakers connected to the system Wired Keypads Use this option to test the sounders on the wired keypads KEY RKPZ Tests the sounders in KEY RKPZ tw...

Страница 134: ...EY RKPZ This test behaves the same as for a wired keypad Expanders The Expanders menu allows you to test individual expanders Radio and wired expanders 12V Input Voltage This option shows the voltage...

Страница 135: ...test When you select a Walk Test option apart from Chime the display shows the first item in a list of the detectors available for test Walk around the area you wish to test and trigger each detector...

Страница 136: ...the list The bottom line of the display shows the zone name To see the zone number press or The end of the bottom line shows the resistance of the zone For 4 wire CC zones the display alternates betw...

Страница 137: ...e output you wish to test followed by to activate the output Press again to deactivate the output Press to finish the test Note If you have programmed one of the plug by outputs as an ATS Test output...

Страница 138: ...e signal strength Prox Tags This allows you to test a user s proximity tag The keypad display shows a message asking you to present the tag to the keypad Hold the prox tag up to the keypad The keypad...

Страница 139: ...owledgement SMS This option appears only if the control unit is fitted with a plug on module that provides PSTN or GSM communications You can use the option to send a test call to any telephone number...

Страница 140: ...tamper alarms that occur in the same unset or set period are logged in the mandatory log Any further events of that type are logged in the non mandatory log How the Log Displays User Identities When y...

Страница 141: ...separate event Unn Config Change if Downloader changes the configuration of the control unit The user number recorded will be that for the Downloader see table above Logging Tamper Events Tamper even...

Страница 142: ...isplay shows the revision of software running on the keypad If you find that the Keypad option does not display an individual keypad s software version you can check the keypad by briefly pressing the...

Страница 143: ...ional Mobile Subscribed Identity IMSI to identify the GSM subscriber Version The firmware version of the module Reset Resets the module For a PSTN module this provides PSTN Link Status which shows the...

Страница 144: ...ly reported A test signal Contact ID The Contact ID format transmits data from the event log to the Alarm Receiving Centre ARC Examples of messages in the Contact ID format are Example 1 1234 18 1137...

Страница 145: ...e log event description The control unit sends those characters shown between and above literally as they appear in the text For example if there is a fire alarm on zone 2 of partition 4 at 10 15 part...

Страница 146: ...th Do not use water solvents or any proprietary cleaning materials Walk test all detectors Test any external sounders and strobes Note You can use Test Locate Bus Device to find the location of a bus...

Страница 147: ...hold down the address request button on the new expander with the tamper switch activated The control unit will assign the bus device address of the expander you removed to the new expander along with...

Страница 148: ...attery 1 charger fault restored Chargr 2 Flt Battery 2 charger fault Chargr 2 Rst Battery 2 charger fault restored Coms O P Flt Plug by comms output fault Coms O P Rst Plug by comms output fault resto...

Страница 149: ...Burg Z Restore Burglar alarm on zone n restored Bus 12V Fail 12V DC supply to Bus nn failed Bus 12V Restore 12V DC supply to Bus nn restored Bus Tamper Rstr Bus n has been restored Bus Tamper Bus n ha...

Страница 150: ...in for Internal Radio Sounder nn ISN Superv Fail Radio signal fail for 2 hours for Internal Radio Sounder nn ISN Superv Rstr Radio signal restored for Internal Radio Sounder nn ISN Tamper Rstr Tamper...

Страница 151: ...unted Shunt Group OFF User nn de activated shunt group n Shunt Group ON User nn activated shunt group n SMS Ex Keys Rstr Excess keys tamper from SMS message restored SMS Excess Keys Excess keys code a...

Страница 152: ...Low Battery WAM has low battery WAM PSU Fail WAM has low power supply WAM PSU Restore WAM low power supply restored WAM RF OK WAM supervision OK WAM RF Warning WAM about to fail supervision WAM Sndr...

Страница 153: ...ain cannot be found Unknown host 515 Destination mailbox address invalid 517 Problem with senders mail attribute check properties 521 domain does not accept mail see RFC1846 522 Recipient has exceeded...

Страница 154: ...eg too many messages exchanged 37648 Internal error eg unexpected failure in lower level module 37776 Unknown identity received eg PSK identity 37904 Public key type mismatch eg asked for RSA key exc...

Страница 155: ...d 41360 Processing of the CertificateRequest handshake message failed 41488 Processing of the ServerKeyExchange handshake message failed 41616 Processing of the ServerHelloDone handshake message faile...

Страница 156: ...Page 146 www touchpoint online com Product Support UK Tel 44 0 1594 541978 Available between 08 30 to 17 00 Monday to Friday email securitytechsupport eaton com Part Number 12664354 31st May 2016...

Отзывы: