Specifications 

MODEL 

HMI04BU 

HMI04CU 

HMI06BE 

HMI06GE 

Display Type 

STN 

TFT LCD 

STN 

FSTN 

Display Color 

8 Blues 

65536 Colors

8 Blues 

16 Grays 

Screen Pixels 

320 x 240 pixels 

LCD Module 

LED Back Light

LED Back Light

CCFL Back Light 

Back-light Life 

About 10,000 

hours half-life at 

25

o

(Note 1)

 

About 30,000 

hours half-life at 

25

o

(Note 1)

 

About 50,000 hours half-life at 

25

o

(Note 1)

 

Display Size 

3.8” (78.8 x 

59.6mm) 

3.5” (70.08 x 

52.56mm) 

5.7” (118.2 x 89.4mm) 

Operation System 

Real Time OS 

MCU 

32-bit RISC Micro-controller / 206.4MHz 

Memory 

Program 
History 
Recipe 
Alarm 
Data Register 

Volatile 
Non-volatile 

1M 

120K 

64K

(Note 2)

 

4K 

 

64K 

1K 

3M 

120K 

64K

(Note 2)

 

4K 

 

64K 

1K 

3M 

360K 

128K 

16K 

 

64K 

1K 

3M 

360K 

128K 

16K 

 

64K 

1K 

Backup Memory 
(Bytes) 

128K 

128K 

512K 

SM Card 

 

 

 

 

EXT. 
Memory 

USB Disk 

 

 

 

 

Extension Interface 

 

 

 

 

USB Host / Client 

1 Host 

(Note 3)

 Ver 1.1 / 1 Client Ver 1.1 

COM1 

RS-232 

COM2 

RS-422 / RS-485 

RS-232 / RS-422 / RS-485 

Serial 
COM 
Port 

COM3 

RS-232 

RS-232 / RS-422 / RS-485 

Function Key 

User defined key x 4 + System key x 1 

Perpetual Calendar 
(RTC) 

Built-in 

Cooling Method 

Natural air circulation 

Safety Approval 
(Waterproof for 
front panel) 

IP65 / NEMA 4X (indoor only)/ CE / UL / cUL / C-Tick

 

Operation Voltage 

DC +24V (-10% ~ +15%) (Please use isolated power supply) 

(Note 4)

 

 

EATON CORPORATION

 www.eaton.com   15 

Содержание HMi Series

Страница 1: ...May 2010 Contents Description Page Preface 1 Safety Information 1 General Description 2 Accessories sold Separately 3 Unpack and Inspect 3 Hardware Features 4 Dimensions and Cut Outs 9 Serial Port Pi...

Страница 2: ...grounding maintenance and inspection warnings and guidelines are followed For information on HMi software installation and operation please refer to the HMisoft user manual WARNING Comply with instru...

Страница 3: ...any internal or exposed electrical parts of the device or electrical shock may result Do not remove the operator interface while power is applied or electrical shock may result Wait at least 10 second...

Страница 4: ...cations and application upload download ELC PS01 1 amp 24V DC power supply ELC PS02 2 amp 24V DC power supply HMI SPKIT Spare Parts Kit for HMi Operator Interface HMI04 GASKET 2 Spare Gaskets for 4 HM...

Страница 5: ...A Power Input Terminal B COM2 C COM1 Note D USB E Startup Switch UP position Run Mode DOWN position Boot Menu NOTE For simultaneous communications wire one DB9 connector for COM1 and COM3 according to...

Страница 6: ...er Input Terminal B COM2 Note C COM1 D Battery Cover E USB Host F USB Client G System Key NOTE For simultaneous communications wire one DB9 connector for COM2 and COM3 according to the pinout diagram...

Страница 7: ...06CE A Power Input Terminal B Expansion Slot C Smart Memory Card Slot D COM2 Note E COM1 F USB NOTE For simultaneous communications wire one DB9 connector for COM2 and COM3 according to the pinout dia...

Страница 8: ...ut Terminal B Expansion Slot C Smart Memory Card Slot D COM2 Note E COM 1 F USB G Battery Cover NOTE For simultaneous communications wire one DB9 connector for COM2 and COM3 according to the pinout di...

Страница 9: ...ut Terminal B Expansion Slot C Smart Memory Card Slot D COM2 Note E COM 1 F USB G Battery Cover NOTE For simultaneous communications wire one DB9 connector for COM2 and COM3 according to the pinout di...

Страница 10: ...HMi Series Instruction Leaflet Dimensions and Cut Outs 4 HMi HMI04BU HMI04CU 6 HMi HMI06BE HMI06GE HMI06CE HMI06CU EATON CORPORATION www eaton com 9...

Страница 11: ...HMi Series Instruction Leaflet 8 HMi HMI08CE 10 HMi HMI10CE EATON CORPORATION www eaton com 10...

Страница 12: ...232 COM3 Not Used COM3 Used PIN COM1 COM3 COM1 COM3 1 2 RX RX 3 TX TX 4 5 GND GND GND 6 7 RTS TX 8 CTS RX 9 Not Used Note Blank No connection COM2 Pinout for RS 422 RS 485 PIN RS 422 RS 485 G GND GND...

Страница 13: ...COM2 COM3 COM2 COM3 1 2 RX RX 3 TX TX 4 D 5 GND GND GND 6 7 8 9 Not Used D COM2 and COM3 DB 9 Pinout for COM2 and COM3 RS 485 COM3 Not Used COM3 Used PIN COM2 COM3 COM2 COM3 1 D D 2 3 4 D 5 GND GND GN...

Страница 14: ...d PIN COM2 COM3 COM2 COM3 1 2 RX RX 3 TX TX 4 5 GND GND GND 6 7 RTS TX 8 CTS RX 9 Not Used COM2 and COM3 DB 9 Pinout for COM2 and COM3 RS 485 COM3 Not Used COM3 Used PIN COM2 COM3 COM2 COM3 1 RX RX 2...

Страница 15: ...changed from the System menu 6 HMI06BE HMI06GE HMI06CE 8 HMI08CE 10 HMI10CE Recommended wiring Type Wire Gauge AWG Stripped length Torque Solid 28 12 7 8 mm 4 5 lb in Stranded 28 12 7 8 mm 4 5 lb in D...

Страница 16: ...ler 206 4MHz Memory Program History Recipe Alarm Data Register Volatile Non volatile 1M 120K 64K Note 2 4K 64K 1K 3M 120K 64K Note 2 4K 64K 1K 3M 360K 128K 16K 64K 1K 3M 360K 128K 16K 64K 1K Backup Me...

Страница 17: ...7 25 x 5 67 x 1 85 184 1 x 144 1 x 47 Panel Cutout W x H in Inches mm 4 68 x 3 65 118 8 x 92 8 6 79 x 5 21 172 4 x 132 4 Weight in Lbs kg 69 315 62 310 1 69 768 NIT Rating 100 cd m2 300 cd m2 130 cd...

Страница 18: ...ontroller 206 4MHz 32 bit RISC Micro controller 266MHz 32 bit RISC Micro controller 206 4MHz Memory Program History Recipe Alarm Data Register Volatile Non volatile 3M 7M 7M 7M 360K 128K 16K 64K 1K 12...

Страница 19: ...85 184 1 x 144 1 x 47 9 57 x 7 01 x 2 06 243 1 x 178 1 x 52 4 11 70 x 8 74 x 2 01 297 1 x 222 1 x 51 1 Panel Cutout W x H in Inches mm 6 79 x 5 21 172 4 x 132 4 9 11 x 6 55 231 4 x 166 4 11 2 28 3 x 8...

Страница 20: ...HMi Series Instruction Leaflet...

Отзывы: