background image

4

EATON    

 IB528001EN

    

 Installation instructions

Installation Instructions - Arena Series

INSTALLATION

Step 1 – Mount The Luminaire

The first step is to attach the luminaire to the mounting structure. The mounting structure may be a light pole cross arm, an 

indoor catwalk bracket, or other structural component that will hold the Luminaire in place. Refer to photometric drawings or 

project Installation Drawings for luminaire installation locations and any additional mounting instructions.

WARNING

It is the responsibility of the installer to verify that all proposed mounting structures including poles, cross arms, 

catwalk brackets, and other mounting structures are certified to support the weight of the luminaires, withstand 

wind loads, and meet all other applicable codes and regulations. FAILURE TO FOLLOW THIS WARNING MAY LEAD TO 

DEATH, SEVERE INJURY, OR PROPERTY DAMAGE.

WARNING

Do not suspend any luminaire by electrical or control wires, as these will not support the weight of the Luminaire, 

resulting in the potential for the Luminaire to fall and cause damage or injury. FAILURE TO FOLLOW THIS WARNING 

MAY LEAD TO DEATH, SEVERE INJURY, OR PROPERTY DAMAGE.

Equipment Required:

Mounting Hardware

Socket wrenches and/or crescent wrenches sized to fit mounting hardware

Cable ties or wire management restraints (For outdoor installations use UV rated material)

otee:

N

Before mounting luminaires, refer to the steps below to verify correct installation.

WARNING

Do not attempt to connect Arena Luminaires to any circuits with nominal voltage outside the below ranges for high 

voltage and low voltage power supplies, respectivelye:

Between 120V AC and 277 V AC for low voltage power supplies

.

Between 347V AC and 480V AC for high voltage power supplies

In other words, make sure the circuit voltage matches the power supply ratings defined in the table above. FAILURE 

TO FOLLOW THIS WARNING MAY LEAD TO LUMINAIRE INTERNAL DAMAGE AND FAILURE.

Power Quality

The voltage on the lighting circuits must stay within 3% of nominal at 60Hz. Voltage that is consistently too high or low shall 

be corrected before LED luminaires are installed.
If you require assistance in checking your power system or designing or implementing solutions, contact Eaton’s Electrical 

Engineering Services and Systems. Find more information at www.eaton.com.

Arena 600 Current Draw

Voltage (Volts AC)

Current (Amps)

120

5.3

208

3.3

240

2.8

277

2.3

347

2.0

480

1.5

Содержание ephesus Arena Series

Страница 1: ...work FAILURE TO FOLLOW THIS WARNING MAY LEAD TO DEATH SEVERE INJURY OR PROPERTY DAMAGE DO NOT make or alter any open holes in the luminaire Do not modify the luminaire WARNING Follow all applicable s...

Страница 2: ...rque wrench rated to a minimum of 35 ft lbs Step 4 Aim the Luminaire Torque driver with 3 8 hex bit rated to a minimum of 35 in lbs Step 4 Aim the Luminaire Calibrated light meter Step 4 Aim the Lumin...

Страница 3: ...otify Ephesus before proceeding with installation Figure 1 Acceptable Power Configurations WARNING Follow proper grounding methods Electrical system must be grounded If you are not sure if your power...

Страница 4: ...LEAD TO DEATH SEVERE INJURY OR PROPERTY DAMAGE Equipment Required Mounting Hardware Socket wrenches and or crescent wrenches sized to fit mounting hardware Cable ties or wire management restraints For...

Страница 5: ...ost rail in the catwalk structure a Ensure the back set screw is secure to the railing The set screw must make contact with the catwalk railing prior to tightening the nut to prevent loosening Tighten...

Страница 6: ...k or pendant Apply thread locking compound to all threaded connections to prevent loosening b If attaching to the 5 16 18 threaded stud torque all hardware connections to minimum of 10 ft lbs Apply th...

Страница 7: ...with the Luminaire FAILURE TO FOLLOW THIS WARNING MAY LEAD TO DEATH SEVERE INJURY OR PROPERTY DAMAGE Electrical Power Control Connections Wiring connections Connect the incoming power wires to the Lu...

Страница 8: ...receiving the signal may result in transient or fluttering control signals which can cause damage to the luminaire FAILURE TO FOLLOW THIS WARNING MAY LEAD TO LUMINAIRE INTERNAL DAMAGE AND FAILURE Con...

Страница 9: ...of the LED lighting solution to ensure that light is evenly distributed on the playing surface There are two basic methods to properly aim a sports venue Precision Laser Aiming by Coordinates and Ori...

Страница 10: ...e offset by the mounting bracket arm Figure 8 Tilt 90 270 0 180 Tilt Angle Figure 7 Orient 180 270 90 0 Orient is a vector in the Z plane looking down on the luminare from above ORIENT Orient Angle Ti...

Страница 11: ...Digital Range Finder Paper Plates Spare batteries for Laser or charger if needed Laser or Aiming Tube Aiming Mount 1 5 16 Socket Wrench or impact driver For hex nuts on center stud mounts Orient aimin...

Страница 12: ...cket connects to the LED modules c Retighten all hardware after the Luminaire is aimed to the correct point Note N Luminaire may shift while tightening After tightening Luminaire bolts briefly turn la...

Страница 13: ...ted foot candle readings are taken at 3 above ground holding the meter out at arm s length as much as possible thereby reducing the effect of the shadow from your body Note N Take horizontal readings...

Страница 14: ...ver time depending on the environmental conditions at the installation site Proper care of the luminaires will maintain their performance and appearance Follow a regular maintenance schedule to retain...

Страница 15: ...15 EATON IB528001EN Installation instructions Installation Instructions Arena Series...

Страница 16: ...odas las marcas comerciales son propiedad de sus respectivos propietarios Product availability specifications and compliances are subject to change without notice La disponibilit du produit les sp cif...

Отзывы: