Eaton Ellipse ASR 450 Скачать руководство пользователя страница 5

5

MAU-00049 AC

Ellipse ASR 450

 Nominal input voltage

 Input frequency

 Voltage/frequency of battery backup 

outlets  

 6   

in battery mode

 Total output current for the 4 outlets

 Output current of battery backup outlets   

6

 Leakage current

 Input protection

 Transfer time

 Telephone surge protection

 Sealed lead-acid battery

 Automatic battery test

 Average battery life 

 Operating temperature

 Storage temperature

 Operating relative humidity

 Operating elevation

 Safety standards

 Electromagnetic compatibility standards

 Warranty

184 V - 264 V

50/60 Hz

230 V (50/60 Hz ± 1 Hz) 

with pseudosinusoidal wave

5 A max

0.03 mA

5 A resettable circuit breaker

5 ms typical

Tel, ISDN, ADSL, Ethernet

Once a week

4 years typical, depending on number 

of discharge cycles and temperature

0 to 35°C

-25°C to +55°C

0 to 85%

0 to 2000 m

IEC 60950-1, IEC 62040-1-1, CE certified

IEC 62040-2 

2 A max 

12 V, 4.5 Ah

 

UPS

 power

450 VA / 250 W

2 years

Содержание Ellipse ASR 450

Страница 1: ...Installation and user manual English Fran ais Deutsch Italiano Espa ol Nederlands Portugu s Polski esky Solven ina Slovensko Magyar T rk e Ellipse ASR 450 w w w eat on com Pulsar Series...

Страница 2: ...2 MAU 00049 AC Important safety instruction Read before installing the product W arranty Ellipse Installation and user manual Nby 21 Lh Packaging 3 5 1 2 4...

Страница 3: ...3 MAU 00049 AC Quick start 2 t Cffq 6 31 no Ofuxpsl Npefn PS A C FR DIN B D E Product representations not legally binding 2...

Страница 4: ...not to inverse the polarity red and black when connecting the batteries as this will destroy the device Attention lors du raccordement des batteries une inversion des polarit s rouge et noir provoque...

Страница 5: ...tery life Operating temperature Storage temperature Operating relative humidity Operating elevation Safety standards Electromagnetic compatibility standards Warranty 184 V 264 V 50 60 Hz 230 V 50 60 H...

Страница 6: ...e bouton 8 est allum en vert voir figure E Ces prises peuvent tre mises en marche m me si l ASI n est pas connect e au r seau lectrique bouton 8 clignotant Conditions d utilisation Cet appareil est un...

Страница 7: ...signal toutes les secondes L ASI a subit un d faut Les prises secourues 9 ne sont plus aliment es Faire appel au service apr s vente Le voyant vert 7 est teint La protection contre les surtensions n...

Страница 8: ...www eaton com MAU 00049 AC...

Отзывы: