BT, data block transfer
205
02/16 MN05013001Z EN
CPY mode, copy marker ranges
There is one source range and one destination range. The
source range is specified at >I1. The destination range is
specified at >I2. The length of the source and destination
range is specified by the number of bytes at the >NO input.
The content of the source range is copied to the marker bytes
in the destination range.
The function block executes the copy operation if there is a
rising edge from 1 to 1 at the BT..T_ (Trigger) coil.
The error outputs E1, E2 and E3 are evaluated regardless of
the status of the trigger.
Example 1
: Copy of marker blocks, direct definition of
marker ranges
The value of marker byte 10 to 19 is to be transferred to
marker bytes 20 to 29.
• Parameters of function block BT01:
– Source range:
>I1 MB10
– Destination range: >I2 MB20
– Number of bytes:
>NO 10
Source
range
Value of
source marker
range
(decimal)
Destina-
tion
range
Value of desti-
nation marker
range
(decimal)
MB10
42
MB20
42
MB11
27
MB21
27
MB12
179
MB22
179
MB13
205
MB23
205
MB14
253
MB24
253
MB15
17
MB25
17
MB16
4
MB26
4