easy800/MFD control
commands
154
09/10 MN05013007Z-EN
Read/write image data
Overview
h
Please also observe the relevant description of possible
image data provided in the easy800 manual
(MN04902001Z-EN, previous description
AWB2528-1508GB) or in the easySoft Help.
The information provided in Section “General information
on working with image data” on page 61 also applies to
easy700.
Operands Meaning
Read/Write
Comm
and
(hex)
Page
IA1 – IA4
„Local analog inputs: IA1 – IA4“
Reading
02
ID1 – ID16
„Local diagnostics: ID1 – ID16“
Reading
03
IW0
Reading
01
IW1 – IW8
„Inputs of the network station: IW1 – IW8“
Reading
01
M...
Read/Write
0B – 0E
P1 – P4
Reading
06
QA1
Read/Write
05
QW0,
QW1 – QW8
„Local outputs: QW0/ outputs of the network
station: QW1 – QW8“
Read/Write
04
R1 – R16
S1 – S8
„Inputs/outputs of easyLink: RW/SW“
Reading
07/09
RN1 – RN32
SN1 – SN32
„Receive data network: RN1 – RN32/ Send
data network: SN1 – SN32“
Reading
08/0A