Eaton 1400 Series Скачать руководство пользователя страница 1

IMI+70-XF-XC-XP-XT Issue 7 

2400 & 1400 Series (XP, XT, XC & XF) 

Flame Proof Camera Housings 

& Pan Tilt Units

 

 

Installation & Maintenance Instructions

This manual should be read before attempting to connect or operate the equipment

 

This equipment shall be installed in accordance with the latest local/national codes of practice, and standards  

eg :- 

BS EN 60079-14:2014  Explosive atmospheres – Part 14: Electrical  installations design, selection and erection 

(IEC 60079-14:2013) 

IECEx/ATEX Certified 

II 2 G Ex db IIC 
II 2 D Ex tb IIIC

 

Whilst every effort has been made to ensure that all information in this document is correct at the time of 

publication, due to our policy of continuous improvement, the company reserves the right to change any 

information contained herein without notice or reference.  

With the exception to Annexe B which must be referred to the certification Body. 

Содержание 1400 Series

Страница 1: ...s eg BS EN 60079 14 2014 Explosive atmospheres Part 14 Electrical installations design selection and erection IEC 60079 14 2013 IECEx ATEX Certified II 2 G Ex db IIC II 2 D Ex tb IIIC Whilst every effort has been made to ensure that all information in this document is correct at the time of publication due to our policy of continuous improvement the company reserves the right to change any informa...

Страница 2: ...sue 2 0 09 03 2016 Inclusion of Annexes 3 0 05 04 2016 Inclusion of Ex ia removal of ratings page 5 Additions to annexe E 4 0 06 04 2016 Change in Harmonised standard issues 5 0 01 09 2016 Change Cert Number Address authorised signatory Addition of amendment record Special Conditions 6 0 13 10 2016 Change in Name and cert labels 7 0 16 11 2016 Removed DOC ...

Страница 3: ...ion 11 3 3 2 Washer Nozzle Installation 12 3 4 Electrical Installation 13 3 4 1 Electrical Installation XP XT Integrated Pan Tilt housing assembly 13 3 4 2 XP XT Common Connection Examples 14 3 4 3 Electrical Installation XF XC Series units 15 3 4 4 XC XF Common Connection Examples 16 4 0 Maintenance 17 4 1 Corrosion Protection 17 5 0 Labelling 18 5 1 Standard Enclosure label 18 5 2 OP PR Enclosur...

Страница 4: ...X II of ATEX Directive 2014 34 EU 7 Be aware that aggressive substances may require extra protection of the equipment to maintain its integrity and explosion protection 8 The equipment may need additional means of protection if it is to be installed in locations where it may be exposed to excessive external stresses e g vibration heat impact and damage 9 Any repairs or replacement parts must be do...

Страница 5: ...window is made with toughened glass or in the case of the Thermal Imager and Dual Imager versions is made from Infra red transparent material and which is factory fitted with a mechanical window guard The mechanical thermal window guard MUST not be removed There are four system types that are made up from different combinations of the 2400 and 1400 series certified units these are XF series fixed ...

Страница 6: ...ailed connection and configuration of units the installer should refer to individual project specific drawings and information In addition to this manual there are various addendums available that cover the specific function of electronics that can be included within the camera assemblies 2 2 Supplied Equipment Contained in the package are the following items Camera system Installation Technical M...

Страница 7: ... weight of the complete unit Do not stand or place objects directly under installed system Due care must be taken to ensure sufficient clearance is allowed to permit full rotation of the unit with its associated equipment mounted and that the moving unit cannot make contact with personnel It is strongly suggested that where possible the EATON range of mounting brackets are used 3 2 1 Mounting the ...

Страница 8: ...EATON Installation Maintenance Instructions IMI 70 XF XC XP XT Issue 7 2016 Eaton Page 8 of 21 Fig 1 XP26VW Example XP Series unit showing base mount fixing points Fig 2 BPW6800 Wall Bracket ...

Страница 9: ...ation Maintenance Instructions IMI 70 XF XC XP XT Issue 7 2016 Eaton Page 9 of 21 Fig 3 XC40VW Example XC Series unit showing shaft mount fixing points Fig 5 BFP0600 900 1200 Column Spacer Fig 4 BFW5000 Wall Bracket ...

Страница 10: ...ve a mounting plate on the bottom of the housing tube that have four 4 No M6 Threaded fixing points Fig 6 The type and size of these fixings to be supplied by the user installer and must be suitable for the specific installation requirements To gain flexibility of the cameras view direction one of the EATON is needed these comprise of the BFP00SW Swivel joint Fig 7 the BFW32SW Fig 8 or a combinati...

Страница 11: ...oved prior to installation The correct sunshield fixings for each model are supplied with the camera system and should be positioned as detailed below To mount the sunshields first they must be positioned correctly and fixed with a Nylon spacer between the sunshield and the camera housing the M6 A4 Button head screws supplied must have the red fibre washer fitted before fixing the sunshield Fig 9 ...

Страница 12: ...able washer nozzle and mounting bracket These should be fitted during installation with the supplied fixing and positioned to allow cleaning fluid to reach the camera housing window when the wash command is sent The supplied washer nozzle brackets are specific to housing type and are delivered pre aligned for use Fig 11 12 When a wash command is sent to the camera the unit will move to the factory...

Страница 13: ...y Voltage 3 4 1 Electrical Installation XP XT Integrated Pan Tilt housing assembly 1 Always use colour coded conductors or other identification of conductors for ease of wiring and identification of function at a later date 2 Keep a wiring diagram with the system for later use and reference 3 Provision is made for one cable entry at the base mount of the pan tilt Fig 14 To maintain the certificati...

Страница 14: ... DATA A DATA B 230VAC L VIDEO SCREEN VIDEO SIGNAL 110VAC N DATA A DATA B 110VAC L VIDEO SCREEN VIDEO SIGNAL 24VAC N DATA A DATA B 24VAC L VIDEO SCREEN VIDEO SIGNAL 230VAC MODEL WITH NO PUMP OUTPUT 110VAC MODEL WITH NO PUMP OUTPUT 24VAC MODEL WITH NO PUMP OUTPUT NC EARTH NC EARTH NC EARTH EARTH EARTH 110VAC N 110VAC L 110VAC FIBRE OPTIC MODEL 230VAC N 230VAC L 23VAC IP MODEL NC EARTH EARTH RJ45 INL...

Страница 15: ...ase order for as built wiring and connection details of the unit Warning This cover must not under any circumstances be removed until at least 5 minutes after the disconnection of power source To gain access to the internal camera rail first the rail will need to be slid out to allow connections to be made If a wiper is fitted first take note of the parked position of the wiper arm and then remove...

Страница 16: ...VAC PUMP SUPPLY N 24VAC PUMP SUPPLY VIDEO DIRECT TO CAMERA 24VAC MODEL WITH PUMP OUTPUT J1 TH HEATER 22 O 10W HEATER 22 O 10W J3 J2 24VAC N DATA A DATA B 24VAC L NC EARTH SWITCH L 24VAC PUMP SUPPLY N 24VAC PUMP SUPPLY VIDEO DIRECT TO CAMERA 24VAC N 24VAC L EARTH DATA A DATA B 24VAC MODEL NO PUMP OUTPUT J1 TH HEATER 22 O 10W HEATER 22 O 10W J3 J2 24VAC N 24VAC L EARTH 24VAC IP MODEL NO PUMP OUTPUT ...

Страница 17: ...asher nozzle Check and if necessary replace the window wiper blade assembly Please read and be familiar with the instructions before servicing the Pan Tilt or housing 4 1 Corrosion Protection Although all external metal components are produced from 316L Stainless Steel if the units are not correctly maintained handled and cleaned there is the possibility of mild discolouration due to Oxidation If ...

Страница 18: ...inyl and affixed product The contents of the label will be in ENGLISH The label shows A Name of Manufacturer B Model Type and reference C Operating Voltage D EX ratings E ATEX Certificate IECEX certificate numbers F Serial Number G Notified Body Number 5 1 Standard Enclosure label 5 2 OP PR Enclosure label 5 3 OP IS Enclosure label 5 4 Ex ia Ga Enclosure label ...

Страница 19: ...g 4 x M10 fixings on 182mm pcd Standalone housing Depending on mounting brackets Supply voltage 24VAC 50 60Hz or 100 to 230VAC with integral transformer Power consumption Max 120 Watts depending on model 7 0 Special Conditions for Safe Use 1 No modifications must be made to the flamepaths of the unit without consultation of the drawings listed on the schedule 2 Temperatures could exceed 70 C at th...

Страница 20: ...impedance of 50Ω and have a minimum degree of protection IP6X If the antenna utilizes a wire conductor the minimum diameter shall be 0 1mm Alternatively if a track antenna is used the tracking shall have a minimum width of 0 4mm 8 The antenna circuit does not meet the dielectric strength requirements of Clause 6 3 13 Refer to manufacturers instruction manual for further details Labelling Details I...

Страница 21: ...window assemblies integrity of the welded construction shall also be verified during routine overpressure testing Empty enclosures may be tested The individual parts of a flameproof enclosure for example cover and base can be tested separately The test conditions shall be such that the stresses are comparable to those to which these parts are exposed in the complete enclosure If required during th...

Отзывы: