APPLICATION MANUAL 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

ICC COOLING STORAGE UNIT 

ICC/ICU SYSTEM 

 

 

 

 

 
 

 

 
 

Eaton-Williams Ltd 

Station Road – Edenbridge – Kent – TN8 6EG 

Tel:  +44 (0)1732 866066  Fax  +44(0)1732 866653 

www.eaton-williams.com

 

 

 

Содержание ICC25

Страница 1: ...on n W Wi il ll li ia am ms s L Lt td d APPLICATION MANUAL ICC COOLING STORAGE UNIT ICC ICU SYSTEM Eaton Williams Ltd Station Road Edenbridge Kent TN8 6EG Tel 44 0 1732 866066 Fax 44 0 1732 866653 www...

Страница 2: ...0142117A...

Страница 3: ...System Options 7 3 1 ICC ICU System Options 7 3 2 ICC Option Part Numbers 7 4 System Duty Ratings 8 5 System Performance Details Indoor Unit 8 6 System Performance Details Outdoor Unit 8 7 Mechanical...

Страница 4: ...ICC ICU SYSTEM APPLICATION MANUAL August2003 E Manuals Others Qualitair ICC 0412117 4...

Страница 5: ...de The coil is fitted with a de ice system as standard and the on off switch and temperature adjustment control are located on the front of the unit 1 3 Indoor unit Options Electro mechanical or elect...

Страница 6: ...70 J70693 ICCm70 J70691 ICU80 J90783 Low Temperature Storage Systems 3 Phase ICC Electro Mechanical ICC Electronic ICC Electronic Heater ICC Electromech Heater ICU Condenser ICCm 55 J70662 ICCe 55 J7...

Страница 7: ...ICC DIMENSIONAL DETAILS ICC 25 ICC 35 ICC 50 ICC 60 ICC 70 A 475 475 475 525 525 B 390 390 390 440 440 C 805 805 805 865 865 D 450 450 450 525 525 E 680 680 680 740 740 F 680 680 680 680 680 G 62 62 6...

Страница 8: ...117 8 2 3 ICU DIMENSIONAL DETAILS CLEARANCES Figure 2 2 ICU Unit Positioning Figure 2 3 ICU Unit Fixing ICU 30 ICU 40 ICU 55 ICU 80 Width mm 720 720 800 800 Height mm 610 610 765 765 Depth mm 250 250...

Страница 9: ...Outdoor electrical isolator J972434 J972434 J972434 J972434 Wall mount brackets J972435 J972435 J972636 J972636 Crankcase Heater STD STD J213100127 J213100127 OUTDOOR ELECTRICAL ISOLATOR J972434 This...

Страница 10: ...ICC25 ICC35 ICC55 ICC60 ICC70 Electric heater duty kW 3 0 3 0 3 0 4 0 4 0 Air volume flow m3 s 0 51 0 62 0 62 0 73 0 95 Air throw m 7 5 12 12 12 13 Indoor unit noise level NR 52 57 57 57 59 Unit heigh...

Страница 11: ...nt Pipe Sizes Refrigerant pipes sizes are tabled on the following page Ancillary Information Liquid line insulation Optional 3 8 Optional 3 8 Optional 3 8 Optional 3 8 Optional 3 8 Suction line insula...

Страница 12: ...8 5 None 5m 25g m Liquid ICU40 Suction 15 None 5m 25g m Liquid ICU55 Suction 8 None 5m 40g m 3 8 Liquid 30m 105g m 1 2 liquid ICU80 Suction 30 None 5m 40g m 3 8 Liquid 30m 105g m 1 2 liquid Note a DO...

Страница 13: ...ooling Electric Heating Unit 13 6 13 8 13 8 18 7 18 7 18 7 18 7 System Fuse Rating A Phase HRC Cooling Only Unit 10 10 16 20 10 20 10 Cooling Only unit with heaters 16 16 16 20 20 20 20 Unit Internal...

Страница 14: ...tching 8 fpi 8 fpi 8 fpi 8 fpi 8 fpi No of Circuits 1 3 3 4 4 Finned Length 582 582 582 640 640 No of rows deep 2 4 4 4 4 No of Tubes High 17 17 17 20 20 Holding Charge Nitrogen Nitrogen Nitrogen Nitr...

Страница 15: ...Electro Mechanical 8 to 23 C 8 to 23 C 8 to 23 C 8 to 23 C 8 to 23 C Electronic 4 to 23 C 4 to 23 C 4 to 23 C 4 to 23 C 4 to 23 C Electrical Heater Construction Stainless Steel Stainless Steel Stainle...

Страница 16: ...frigerant Holding Charge R407c 600g 1100g 1600g 1900g Suction and Liquid Connections Device Shut Off Valve Shut Off Valve Shut Off Valve Shut Off Valve Connection Flare Flare Flare Flare Electrical Co...

Страница 17: ...Others Qualitair ICC 0412117 17 12 OUTDOOR UNIT OPTIONS SPECIFICATION Outdoor Unit ICU30 ICU40 ICU55 ICU80 Outdoor Electrical Isolator Rating 32A 32A 32A 32A Lockable Yes Yes Yes Yes Wall Mount Bracke...

Страница 18: ...ard U K models are fitted with a low ambient fan speed controller and a low and high pressure switch start short cycle timers winter start 13 3 ICC Indoor Unit Specification Compliance The ICC cooler...

Страница 19: ...ficient heat transfer Fan The fan shall be an energy efficient sickle bladed axial type with the impeller orientated for sucking configuration complete with fan guard Compressor The unit shall be fitt...

Страница 20: ...9 J70631 J70641 J70661 J70681 J70691 ICC25 35 45 55 60 70 Cooling Only Electronic A3LBD150 J70630 J70640 J70660 J70680 J70690 ICC25 35 45 55 60 70 Heat Only Electronic A3LBD151 J70633 J70643 J70663 J7...

Страница 21: ...ICC ICU SYSTEM APPLICATION MANUAL August2003 E Manuals Others Qualitair ICC 0412117 21...

Страница 22: ...ICC ICU SYSTEM APPLICATION MANUAL August2003 E Manuals Others Qualitair ICC 0412117 22...

Страница 23: ...ICC ICU SYSTEM APPLICATION MANUAL August2003 E Manuals Others Qualitair ICC 0412117 23...

Страница 24: ...ICC ICU SYSTEM APPLICATION MANUAL August2003 E Manuals Others Qualitair ICC 0412117 24...

Страница 25: ...ICC ICU SYSTEM APPLICATION MANUAL August2003 E Manuals Others Qualitair ICC 0412117 25...

Страница 26: ...ICC ICU SYSTEM APPLICATION MANUAL August2003 E Manuals Others Qualitair ICC 0412117 26...

Страница 27: ...ICC ICU SYSTEM APPLICATION MANUAL August2003 E Manuals Others Qualitair ICC 0412117 27...

Страница 28: ...ICC ICU SYSTEM APPLICATION MANUAL August2003 E Manuals Others Qualitair ICC 0412117 28...

Страница 29: ...ICC ICU SYSTEM APPLICATION MANUAL August2003 E Manuals Others Qualitair ICC 0412117 29...

Страница 30: ...ICC ICU SYSTEM APPLICATION MANUAL August2003 E Manuals Others Qualitair ICC 0412117 30...

Страница 31: ...ICC ICU SYSTEM APPLICATION MANUAL August2003 E Manuals Others Qualitair ICC 0412117 31...

Страница 32: ...ICC ICU SYSTEM APPLICATION MANUAL August2003 E Manuals Others Qualitair ICC 0412117 32...

Страница 33: ...ICC ICU SYSTEM APPLICATION MANUAL August2003 E Manuals Others Qualitair ICC 0412117 33...

Страница 34: ...ICC ICU SYSTEM APPLICATION MANUAL August2003 E Manuals Others Qualitair ICC 0412117 34...

Страница 35: ...ICC ICU SYSTEM APPLICATION MANUAL August2003 E Manuals Others Qualitair ICC 0412117 35...

Страница 36: ...ICC ICU SYSTEM APPLICATION MANUAL August2003 E Manuals Others Qualitair ICC 0412117 36...

Страница 37: ...ICC ICU SYSTEM APPLICATION MANUAL August2003 E Manuals Others Qualitair ICC 0412117 37...

Страница 38: ...ICC ICU SYSTEM APPLICATION MANUAL August2003 E Manuals Others Qualitair ICC 0412117 38...

Страница 39: ...ICC ICU SYSTEM APPLICATION MANUAL August2003 E Manuals Others Qualitair ICC 0412117 39...

Страница 40: ...uals Others Qualitair ICC 0412117 40 STATION ROAD EDENBRIDGE KENT TN8 6EG TEL 01732 866066 FAX 01732 867937 AN EATON WILLIAMS COMPANY As part of the policy of continuous product improvement we reserve...

Отзывы: