the fog out let should not be shorter than 1 meter.

4

The outlet of the fog should be 1 meter from the equipment at least, and the total
diameter of the mist vent is not less than the diameter of the mist vent of the
equipment.

5

The equipment is not suitable for long-term use in the environment of high
temperature (≥50℃), high dust, strong magnetism and acid and alkali gas.

6

Water tank cleaning period please according to the actual situation, we
recommend once a month least.

7

Please drain out the water if the machine is out of working for long time.

8

Please don’t dig hole on the cover of the machine directly when install the water
filter.

9

The power supply must be cut off, if the machine stop working over 48 hours,
and the water storage in the tank must be drained out entirely. As if the storage
water stocked too long time, it will become ropy, this will affect the function
of the equipment.

10

The overflow and drain pipes must be connected to the floor drain to avoid

accident caused by leakage.

9. After-sales service

1

1 year warranty for the whole machine.

2

Atomized ceramic wafers, filter and fans are belong to the consumables, it’s not

covered by the warranty. If you need to replace them , please contact us ,we will
supply them to you at cost price. You can also buy them in your own in local.

3

The power supply must be cut off, if the machine stop working over 48 hours,

and the storage water in the tank must be drained out entirely. As if the storage
water stocked too long time, it will become ropy, this will affect the function of
the equipment.

4

The overflow and drain pipes must be connected to the floor drain to avoid

accident caused by leakage.

Содержание EW-08HS

Страница 1: ...iguration and technical parameters 2 3 Filter installation and cleaning 3 4 Installation instruction 3 5 Atomization system 5 6 Regular failure and failure elimination 7 7 Maintenance 8 8 Precautions...

Страница 2: ...e the water leaving the cover to create the water mist shape no need to heat or chemical to produce 1 to 5 mu water particles floating in the air thereby to improve the air quality and improve the env...

Страница 3: ...or so to clean the filter element impurities or replacement Turn on the water filter bottle take out the filter element and wash it then put it back to the filter cover if the filter element with too...

Страница 4: ...12m the spacing should be with 15 20cm Please also block off the end of the pipe so as to avoid water accumulation in the pipeline the level height of the ends should be adjustable slightly above the...

Страница 5: ...components The worst result is cause accidents It is recommended that the equipment be separated from the humidifying room where the humidity is higher than 85 RH 5 Atomizing system The indicator lig...

Страница 6: ...ion as following a Cut off the power drain the water from the tank and dry the water on the surface of the atomizer b Unscrew the pressure ring with the lock piece remove the old atomizer chip and kee...

Страница 7: ...placed b There is foreign matter in the float c The float is damaged a Adjust it to the correct position b Remove the foreign matter c Replace the float No fog outlet a The voltage 5 lower than the st...

Страница 8: ...g screw on the cover of the water tank and open the tank cover plate please pay attention to the circuit connection inside use a soft cotton close or brush to clean Dish soap is available see Fig 12 T...

Страница 9: ...the water storage in the tank must be drained out entirely As if the storage water stocked too long time it will become ropy this will affect the function of the equipment 10 The overflow and drain pi...

Страница 10: ...fter sales will give free maintenance The artificial damage and the damage caused by the irresistible force are not covered in the warranty We will charge a trend in the maintenance if the machine is...