GB
Plug-In Radio Alarm Annunciator RTRP02
Models
Scope of Delivery
Alarm annunciator RTRP02, Operating
instruction
Technical Details
Safety A
dvice
Concept of Operations
The alarm indicator RTRP02 may only be used in
dry indoor rooms as acoustic signalling device for
alarm messages and messages concerning the
battery status of the window handle contact
RTS26 (evaluation of undervoltage diagram).
The outlet can only be used for mains voltage
consumers (10 A, 230 V AC, 50 Hz).
The manufacturer will not be liable for damage
caused by improper or inappropriate use.
Intended Use
Wall outlet
Loudspeaker
Button 1/LED 1
Button 0/LED 0
OFF
Battery control
notice
Frequency:
868.30 MHz
Modulation:
FSK
Channel:
1x receive
/
2x transmit
Range:
up to 150 m under
favourable open field
conditions
Operating voltage:
230 V AC / 50 Hz
Current consumption
- real power:
max. 0.6 W
- apparent power: max. 1.8 VA
Degree
of
protection:IP 20
Operating
temperature:
-20°C to +35°C
Max. relative air
humidity:
60%
Mains output:
Power plug
(
)
Max. contact load:
10 A / 230 V AC
Dimensions
(HxWxD)
:
122 x 50 x 38.3 mm
Weight:
approx. 190 g
SPL:
85 dB / distance 30 cm
non switchable
ON
Function/Chapter
Operation
[press the button]
LED-view RTRP02
Result
Memorizing a
Window handle
contact RTS26
1. button 0 + button 1 >1,6 s
button 0
2. button RTS26
LED 0 + LED 1 flashes
LED 1 lights up 3 s
after 20 s operation mode
break
afterwards operation mode
Memorizing an
acknowledgement
transmitter
1. button 0 + button 1 >1,6 s
button 0
2. button 1 >1,6 s
button 0
3.
button acknowledgement trans.
LED 0 + LED 1 flash
LED 1 flashes
LED 1 lights up 3 s
after 20 s operation mode
break
after 20 s operation mode
break
afterwards operation mode
Switch on
alarm function
button 1 >1,6 s
LED 0 + LED 1 light up
Alarm annunciator activates
Switch off
alarm function
button 0 >1,6 s
LED 0 + LED 1 out
Alarm annunciator deactivates
Acknowledge the
alarm
button 0 oder button 1
or
button acknowledgement transm.
Further alarm messages are
possible after 5 minutes.
Switch on lighting
(Transmission
code A1 (ON)
transfer)
1. button 0 + button 1 >1,6 s
button 0
2. button 1 >1,6 s
button 0
3. button 1
LED 0 + LED 1 flash
LED 1 flashes
LED 1 lights up 3 s
after 20 s operation mode
break
after 20 s operation mode
break
Send code A1 is sent for 3 s,
afterwards operation mode
Close a shutter
(Transmission
code B2 (DOWN)
transfer)
1. button 0 + button 1 >1,6 s
button 0
2. button 0 >1,6 s
3. button 0
LED 0 + LED 1 flash
LED 0 flashes
LED 0 flashes 3 s
after 20 s operation mode
break
after 20 s operation mode
Send code B2 is sent for 3 s,
afterwards operation mode
Reset to Default
Settings (RESET)
1. button 0 + button 1 >1,6 s
button 0
2. button 0 + button 1 >1,6 s
LED 0 + LED 1 flash
LED
0
+
LED
1 light up 3 s
after 20 s operation mode
break
dann operation mode
Undervoltage
message window
handle contact
acknowledge with
button 0 oder button 1
battery control notice
flashes
change the battery of the
window handle contact
Carefully read through these
instructions before using the
device.
We do not accept any liability for personal
injury or damage to property caused by
incorrect handling or non-observance of the
safety instructions!
Keep the Alarm annunciator away from
children!
Attention!
Observe the admissible supply
voltage and the maximum contact load of the
wall outlet (10 A, 230 V AC / 50 Hz)!
Do not plug one Alarm Annunciator into
another.
The device is only de-energized when it is
disconnected from the mains supply.
The device must be easily accessible.
Observe the valid laws and regulations as well
as the manufacturer's instructions
Have malfunctioning devices checked by the
manufacturers!
Do not open the appliance's casing!
Do not make any unauthorized alterations or
modifications to the device!
for the
devices to be operated.
The alarm indicator RTRP02 is a wireless
receiver that reports manipulations to the window
handle by emitting an acoustic signal in
connection with an activated wireless window
handle contact RTS26.
Altogether 32 window handle contacts can be
monitored by the alarm indicator.
It is also possible to evaluate an undervoltage
telegram indicating the low battery status of a
window handle contact.
The low battery status is signalled with a blinking
battery status display and can be deactivated by
pressing the button 1 or 0 on the alarm indicator.
This function is also available when the alarm
indicator is deactivated.
Function
D/A/NL/S/N
CH
GB
F/B/PL
Schuko
RTRP02E5001
RTRP02E5001-02
868.30 MHz
GB
RTRP02E5001-04
868.30 MHz
F/B
RTRP02E5001-05
868.30 MHz
CH
-01
868.30 MHz
D