background image

E8 D1 Manual 
 

1 of 9 

D1 Swing Gate Control Board Manual 

Imported by www.gateopener.co.nz PO Box 9215 Tauranga New Zealand 

[email protected]  

Warning: Insure you have sealed all means of 

entry to the control box by insects and water. 

 

 

 

Control Panel 

– Model D1 

The Easysystems D1 control panel is specially design to match 12Vdc Arm 
Gate Motor(s).  

The electronic panel requires no maintenance as long as the gate operates in 
proper order and is kept dry and insect free. Mount the Control box as close to 
the motor(s) (maximum 10m cable) as possible connected with minimum 
1.5mm 2-core electrical cable to reduce any voltage drop which will affect the 
performance of the system. 2.5mm to 4mm house cable is commonly used.  

1.  Make sure all wiring works are correct and in good condition before 

supplying the mains power to the control panel. 

2.  Turn 

OFF

 the power when doing any maintenance. 

3.  Ensure the control panel box free from water leakage to avoid short 

circuiting. 

4.  Do not supply mains power directly to the motor. 
 

Содержание D1

Страница 1: ...gate operates in proper order and is kept dry and insect free Mount the Control box as close to the motor s maximum 10m cable as possible connected with minimum 1 5mm 2 core electrical cable to reduce any voltage drop which will affect the performance of the system 2 5mm to 4mm house cable is commonly used 1 Make sure all wiring works are correct and in good condition before supplying the mains po...

Страница 2: ...mains power supply to the 2 x orange wires 230Vac at the transformer Connect 2 x white wires 16Vac to control board block 1 AC input As the input is AC the polarity of the cables need not be observed Disregard the purple and black wires if fitted as these are for our 24VAC sliding gate control board D2 only Protect the wire ends so as not to make contact with the transformer DIP SWITCH setting on ...

Страница 3: ...le and bottom so care must be taken when setting each DIP switch Match the new remote DIP settings to the working current remote DIP switch positions Check the signal transmission by pressing your new remote Changing Remote Codes Positioned inside your gate opener control box is the remote Receiver box with 5 wires connecting to your control board Open this up to view the code DIP switches which i...

Страница 4: ...n low speed until gate s are fully opened Check that the LED lights at block 2 are green If red LED is observed disconnect power then reverse arm wire in question and start setup again from step 1 4 Both the motor will stop automatically when the gate is hard stopped High current cut off by the circuit board is automatically achieved 5 Press remote transmitter again and let the motor close high sp...

Страница 5: ...ilure the arms will open simultaneously but closes sequentially i e 1 x arm starts after the other finishes This ensures that the battery will be loaded on only 1 arm at any one time The cycle will be 20 30 slower then if powered with transformer External auto close switch The switch installed at the bottom of the control panel is hard wired as 30 sec Auto Close only You must place 7 and 8 to OFF ...

Страница 6: ... from being forced open when fully closed Connect to lock at block 3 DIP switch 2 is placed to ON to allow lock tongue to release freely a second before gate performs an open cycle Loop Detector Free Exit Function Connect the Loop Detector signal cables to Block 6 In the Free Exit Mode a command via the loop detector or underground motion sensor will cause the gate the open If another command is m...

Страница 7: ...to the fact that the Lamp Photocell is exposed to significant lighting When connected to Pillar Lights this design prevents the Pillar Light from turning ON during the Day If you wish that the Pillar Lights be turned on irrespective of the ambient lighting use a Dark Tape to cover the Lamp Photocell or turn the Photocell inwards when mounted in the Control Box Lamp Relay Activated when Lamp Photoc...

Страница 8: ...setup obstructions Problem The gate does not fully open and close or stops half way Ensure there is no obstruction to the movement of the gate This could also be high resistance such as poor gate installation or high winds activating the anti obstruction sensing This can be verified by releasing the gate to Emergency release mode Manual push the gate open and close to detect any obstruction Ensure...

Страница 9: ...FUSE Connect Keypad and Solar Regulator observe Polarity 12 Vdc Relay To Activate 1 Gate To Activate 2 Gate AC Transformer MT B IR BEAM MT A LOCK LAMP RELAY NC P SW 1 2 For Single Arm Use only MOTOR A and Set DIP 5 to ON Loop Detector IR Beam LIGHT SENSOR EASYSYSTEMS D1 SWING GATE CONTROL BOARD version 1 3 0 Warning Insure you have sealed all means of entry to the control box by insects and water ...

Отзывы: