EasySplicer PRO Скачать руководство пользователя страница 1

EasySplicer PRO

USERS MANUAL

1

Содержание PRO

Страница 1: ...EasySplicer PRO USERS MANUAL 1 ...

Страница 2: ...tion 4 Electrodes 4 Singlemode or Multimode 4 Time to splice 5 Oven operation sleeve protection 6 Basic Operation 7 KeyPad 8 Clean electrodes 9 Calibrate 9 Oven operation 10 Dedicated buttons 11 RESET 11 SET 11 ARC 11 X Y 11 HEAT 11 Setup Menu system 12 Para 12 Setup 13 Func 14 Maint 15 Heat 16 Arc 17 State 19 Info 20 Technical Specification 21 Supplier 22 2 ...

Страница 3: ... SB Scandinavia AB tries to make the user manual complete and accurate it may contain mistakes and the user uses it solely at his or her own risk Application Splicing and protection of most common types of SMF and MMF EasySplicer PRO components The following components are included and standard for splicing in the field Item Description Quantity 1 EasySplicer PRO 1 2 Power supply 1 3 Fiber cleaver...

Страница 4: ... bad splice and or no splice then calibrate the unit manually see chapter 4 2 Calibration Electrodes Before beginning to splice You should verify that the electrodes are in good operational condition Check the electrodes as the splicer probably has been stored for a while and lately been in transport If needed clean the electrodes as described in section X by using the CLEAN ELECTRODES function se...

Страница 5: ...uto MM MM For Multimode There are a total of 40 programmes in the list but most are to be used with special settings and special cables There is no need to use most of them unless You are sure of the purpose of the individual programmes Please contact our support if You have any questions comments Time to splice Place 250 fiber in the black holders 900 fiber pigtail in the blue holders and the 900...

Страница 6: ... whole process will be shown in the display live video from both X Y cameras and take less than 10 sec An automatic pull test will be performed after the splicing Finally the splicer will show the estimated splice loss in dB or if the process failed Bad splice if so re do the operation from strip and cleave above Oven operation sleeve protection Open up the oven with the lifting arms left right on...

Страница 7: ...ven is default set for 30 seconds The splicer is ready for another splice while the oven is in operation simply start the above process again Basic Operation The EasySplicer PRO is handled and controlled with the keypad All selected parameters will be shown on the Display 7 ...

Страница 8: ... 7 Right 8 Down Enter the Menu system with Menu button nr 4 Step up down with the arrow keys and select Your choice with the Enter button Go back with the Menu button nr 4 Select immediate manual operations on the keypad on the right hand side for ex force splicing and oven operation Switch between the cameras with the X Y button 8 ...

Страница 9: ...continuously calibrating the strength of the spark in accordance with the surrounding environment temperature and airpressure It can happen that the weather situation changes very fast from for ex sunny to rainy and under such conditions it will be of good use to calibrate the unit manually before starting to splice Performing a Calibration Make sure You have the correct fiber type selected SM MM ...

Страница 10: ...der some circumstances You might want to operate the oven manually If so place a fiber with a shrink tube sleeve in the oven compartment and press the HEAT button The oven will start and the red LED will lit The oven will run for as long as the oven time is set factory preset is 30 sec Change oven time and other heating parameters in the Menu in the section Heat Use the up down buttons to move aro...

Страница 11: ...he arc Open up the main lid and press the button NOTICE don t try to touch or interfere with the spark as it can cause significant injuries which are very hard to heal treat Always operate the EasySplicer PRO with cautiousness X Y In Standby press X Y to switch between camera modes X Y Standard view x125 X Y Magnified view x250 X Camera magnified view x250 Y Camera magnified view x250 back to Stan...

Страница 12: ...ce parameters The EasySplicer PRO can handle Singlemode Multimode DS Dispersion shifted and NZDS Non zero dispersion shifted cables Here You also set the correct fiber type BEFORE You calibrate the splicer For simplicity we recommend You to use the following programmes only Prog 0 Auto SM SM For Singlemode Prog 1 Auto MM MM For Multimode Prog 2 Auto DS DS For DS Prog 3 Auto NZ NZ For NZDS 12 ...

Страница 13: ... be used with special settings and special cables There is no need to use most of them unless You are sure of the purpose of the individual programmes Please contact our support if You have any questions comments Setup In this menu You can setup change various parameters like Camera Brightness and Menu Language Here You can also set Auto Power Off default to Auto Power On 13 ...

Страница 14: ...testing the motors when in Stand by mode and no fiber in the splicer Select the function and then press the Enter button a second time to execute the operation The motors will go in and out and place themselves in Ready mode Stand by 2 Date time Set the proper date time 3 Export Records If You want to make records and documentation of Your splice results then You can download the internal memory u...

Страница 15: ... get back in Stand by mode Ready mode press the RESET button 2 Electrode Stabilize Use this function when exchanging Your worn out electrodes with new ones This function will burn away oxid which might have occurred on the electrodes during transport or longtime storing 3 Fusion Records Enter this function to learn about the individual splices made They are registrated in chronological order Chose...

Страница 16: ...with left right arrows The oven time can be set in steps of 1 sec according to Your needs 2 Temperature Default temperature for the oven is set to 180 degrees Celsius Adjust the temperature with left right arrows The temperature can be set in steps of 5 degrees Celsius according to Your needs 3 Show Temper Displays the oven temperature when in operation Default setting is Off Change value with the...

Страница 17: ...EasySplicer Pro will then check the Arc 2 Arc Calibration Make sure You have the correct fiber type selected SM MM See below Para setting page 12 Strip clean and cleave one fiber from each side left right and place in their fiberholders Then place them in the splicer Always clean the fiber with alcohol isopropyl or similar Make sure not to touch the fiber with anything after cleaning as it will be...

Страница 18: ...bration will be shown in top of the display Press the Enter button and the unit will perform the calibration Successful Calibration Simply redo the above steps if the unit is unsuccessful with the operation You can see a full calibration video at 18 ...

Страница 19: ...he surrounding environment of the unit 1 Pressure Current air pressure 2 Outer Temperature Last measured outdoor temperature in Celcius 3 Inner Temperature Last measured indoor temperature in Celcius 4 Remaining Capacity Remaining battery capacity in 19 ...

Страница 20: ...ion Tells about the software version of Your EasySplicer PRO Check at www easyplicer com to find latest firmware 2 Hardware Version Tells about Your units specific hardware 3 Serial Nr Serial nr of Your EasySplicer PRO 4 FPGA Processor version of the splicer 20 ...

Страница 21: ...0mm Sleeve Dimensions Max 64mm length 2 7mm diameter supported by oven Display LCD color 4 3 Oven Ceramic teflon type 40 60mm sleeves in about 25 sec Electrodes life 4000 splices Magnification Cameras x250 X or Y x125 X and Y together Communication USB 2 0 for uploading splice info and upgrade Splice memory 4000 results internally Altitude Compensation Automatic up to 4000 meters altitude with com...

Страница 22: ...SB Scandinavia AB Ostmastargrand 12 120 40 Stockholm Sweden Tel 46 8 5333 40 70 e mail info easysplicer com Support support easysplicer com web www easysplicer com Org VAT nr SE556410621801 22 ...

Отзывы: