background image

PCA SERIES PUMPS

© 2019 EasyPro, Inc

5730 • 10/19

 — Pg. 1

 IN THE USA

ASSEMBLED

Reliability You Can Count On!

www.easypro.com • 800-448-3873

Installation and Service Manual

for PCA Series

High Flow, Self Priming Centrifugal Pumps

Please fill in for future reference: 
MODEL:

 ________________________________________

SERIAL NUMBER:

 _______________________________

DATE PURCHASED:

 _____________________________

* Please keep copy of original purchase receipt

 HOUSING TYPE:  CORROSION RESISTANT POLYPROPYLENE

 

MOTOR:  NEMA 56Y FRAME

 

VOLTAGE:  3/4 HP: 115/230V; 1.5, 3, 5 HP: 208-230V

 

PORT SIZE:  3" SPIGOT WITH UNIONS

 HORSEPOWER:  .75, 1.5, 3 & 5 HP

 

SEAL:  STATIONARY TYPE - STAINLESS STEEL, WITH BUNA TRIM FOR 

5

/

8

" SHAFT

 

CORD:  .75 HP INCLUDES 6' 115V CORD, NO CORD ON OTHERS

WARNING: 

Please read completely before you install or operate your new pump! 

 

Do NOT allow this pump to become submerged. Never run dry and never reverse rotation.

Thank you for purchasing the PCA Series Pump from EasyPro! To insure proper performance, we urge you to carefully follow the instructions in this 

manual. If you have any questions, call your nearest distributor or EasyPro for assistance.

IMPORTANT SAFETY INSTRUCTIONS

Please read all instructions completely before you install or operate your new pump. Save this manual for future reference.

Содержание PCA75

Страница 1: ... 5 3 5 HP 208 230V PORT SIZE 3 SPIGOT WITH UNIONS HORSEPOWER 75 1 5 3 5 HP SEAL STATIONARY TYPE STAINLESS STEEL WITH BUNA TRIM FOR 5 8 SHAFT CORD 75 HP INCLUDES 6 115V CORD NO CORD ON OTHERS WARNING Please read completely before you install or operate your new pump Do NOT allow this pump to become submerged Never run dry and never reverse rotation Thank you for purchasing the PCA Series Pump from ...

Страница 2: ...ts PVC fittings are available to accommodate 2 21 2 and 3 pipe Quick connect unions are included with each pump All plumbing lines should be self supported and properly aligned This will prevent undue stress to the housing Use a suitable PVC primer and cement to connect your pipe to the fittings 7 Installations in which the discharge pipe is elevated above the pump must use a swing type check valv...

Страница 3: ... box For high voltage 1 Connect your incoming hot lead normally the black wire to wire 1 2 Connect your other hot lead normally the white wire to wire 4 3 Connect wire 2 and 3 together 4 Tape off the wire marked J 5 Use appropriately sized wire nuts to insure all connections are secure and insulated 6 Connect your ground lead normally green to the green screw in the connection box Note Your motor ...

Страница 4: ...k impeller hub with a small straight screw driver 10 Clean the bracket seal bore housing and the motor shaft as necessary PUMP ASSEMBLY 1 To install a new shaft seal clean or replace the o ring in the bore If there is no o ring clean the bore and apply a bead of 100 silicon sealant inside the bore and around the top edge 2 Press the seal into the bore without touching or putting pressure on the de...

Страница 5: ...e open Ensure plumbing is clear including suction strainers check valves etc Clean out leaves or other debris from basket strainer if applicable Insufficient Prime Prime system with water and purge all air from suction piping Cavitation Verify airtight plumbing on the suction plumbing especially fittings Clean out leaves or other debris from basket strainer if applicable Increase pipe size where p...

Страница 6: ...ty For applications that involve fluids other than water the purchaser shall retain and present to EasyPro Pond Products evidence of purchaser s compatibility tests under actual operating conditions Any problems caused by a chemical incompatibility of the fluid with the pump materials are expressly not covered by this warranty No warranty whatsoever of chemical compatibility or application suitabi...

Отзывы: