background image

EX8800 • EX11200 • EX13200

Reliability You Can Count On!

© 2010 EasyPro, Inc

Pg. 1

 TYPE: 

STRAIGHT 

CENTRIFUGAL

 

MOTOR:  NEMA C FACE, 56J

 HORSEPOWER:  1/2 (1750 RPM), 3 (3450 RPM)
 

INLET:  2" FNPT AND BUTTRESS THREAD PORTS

  DISCHARGE:  2" FNPT AND BUTTRESS THREAD PORTS
 

MATERIAL:  40% GLASS-FILLED POLYPROPYLENE

 HARDWARE: 

STAINLESS 

STEEL 

 OPTIONS: 

SALTWATER 

SERVICE

  ACCESORIES:  90 CUBIC INCH STRAINER BASKETS (1.5" & 2")
 

  SWING CHECK VALVES (1.5", 2", 3")

 

  500 CUBIC INCH STRAINER BASKETS

 

  (1.5", 2", 3")

WARNING: Please read completely before you install or operate your new pump! This is an external “out-of-pond” pump!

It is NOT submersible! Do NOT allow this pump to become submerged! Never run dry! Max. case pressure.- 65 PSI!

Please fi ll in for future reference: 
MODEL: ________________________________________
SERIAL NUMBER: _______________________________
DATE PURCHASED: _____________________________

* Please fi ll out the warranty registration card in this manual

EasyPro

EX8800

S/N: XXXX-XXXXXX

 Model 

EX8800 

EX11200  EX13200

 Inlet 

2" 

2" 

2"

 Discharge 

2" 

2" 

2"

  Max Flow (gph) 

8220 

11160 

13200

  Max Head (feet) 

22.3' 

80.8' 

81.7'

  Max Power (watts) 

450 

2162 

2595

  Max Current (amps)  4.0 @ 115v  9.6@230v  11.5@230v
 Volts 

115/230 

230 

230

 Motor HP 

1/2 

3

 Motor Enclosure 

TEFC 

TEFC 

TEFC

 Impeller 

7

Installation and Service Manual

Jolie 

Products 

Inc

Содержание EX8800

Страница 1: ...ternal out of pond pump It is NOT submersible Do NOT allow this pump to become submerged Never run dry Max case pressure 65 PSI Please fill in for future reference MODEL ________________________________________ SERIAL NUMBER _______________________________ DATE PURCHASED _____________________________ Please fill out the warranty registration card in this manual EasyPro EX8800 S N XXXX XXXXXX Model...

Страница 2: ...imed prior to start up Figure 2 2 Mount motor base to a secure immobile foundation 3 Use only plastic fittings on both the intake and discharge ports Seal pipe connections with Teflon paste These fittings should be self supported and in neutral alignment with each port i e Fittings must not be forced into alignment which may cause premature line failure or damage to the pump volute For non flooded...

Страница 3: ...lute to bracket with seven 1 4 20 x 2 3 4 hex cap screws washers and nuts Tighten in a cross pattern 30 in lbf 10 Install drain plug with its O ring in volute drain hole 11 Before operating pump allow a proper cure time for the sealant used in step 2 DISASSEMBLY 1 Shut off power to motor before disconnecting any electrical wiring from the back of the motor 2 Disassemble volute from bracket by remo...

Страница 4: ...perty damage and to the extent not unconscionable for personal injury damage Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you 9 This warranty does not apply to any malfunction arising out of any application of this product other than normal use unless such application is upon request specifically a...

Отзывы: